NONINVASIVE DETERMINATION OF SYSTOLIC BLOOD-PRESSURE BY HEART-SOUND PATTERN-ANALYSIS

被引:21
|
作者
BARTELS, A
HARDER, D
机构
[1] Inst. fur Medizinische Phys. und Biophys., Georg-August-Univ. Gottingen
来源
关键词
D O I
10.1088/0143-0815/13/3/004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new concept of non-invasive blood pressure measurement by heart sound pattern analysis is described. The known diagnostic criterion of the 'accentuated' second heart sound of a hypertensive patient is here converted into a computer-aided pattern-recognition process for the second heart sound, applicable over the entire scale of blood pressure. After a 'learning phase', during which the second heart sound is recorded, analysed and correlated with a set of systolic blood pressure values of the individual patient, the computer is able to determine systolic blood pressure of the same patient from the acoustic spectrum of the second heart sound with sufficient precision. The method is in principle suited for automatically repeated blood pressure measurements, but further development is still needed for conversion into a widely practicable procedure.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [31] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [32] NONINVASIVE MEASUREMENT OF ARTERIAL BLOOD-PRESSURE BY PATTERN OF ELECTRICAL-IMPEDANCE CHANGE
    MISAWA, T
    OKUBO, S
    YAMADA, H
    HONGO, M
    SOGA, N
    KONO, J
    KINOSHITA, O
    KUSAMA, S
    TAKEMAE, T
    MATSUYAMA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1985, 49 (08): : 825 - 825
  • [33] GENETIC-ANALYSIS OF SYSTOLIC BLOOD-PRESSURE IN MELBOURNE FAMILIES
    HOPPER, JL
    TAIT, BD
    PROPERT, DN
    MATHEWS, JD
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1982, 9 (03) : 247 - 252
  • [34] Continuous and Noninvasive Estimation of Right Ventricle Systolic Blood Pressure Using Heart Sound Signal by Deep Bidirectional LSTM Network
    Wang, Miao
    Tang, Hong
    Feng, Tengfei
    Guo, Binbin
    APPLIED SCIENCES-BASEL, 2020, 10 (16):
  • [35] DETERMINATION OF BLOOD-PRESSURE
    SIMPSON, FO
    NEW ZEALAND MEDICAL JOURNAL, 1978, 87 (607) : 188 - 188
  • [36] TIME-FREQUENCY ANALYSIS OF THE FIRST HEART-SOUND
    WOOD, JC
    BARRY, DT
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (02): : 144 - 151
  • [37] AGE-RELATED ALTERATIONS IN HEART-RATE AND BLOOD-PRESSURE DYNAMICS - ASSESSMENT WITH CONTINUOUS NONINVASIVE BLOOD-PRESSURE RECORDING
    RYAN, SM
    LIPSITZ, LA
    MIETUS, J
    GOLDBERGER, AL
    CLINICAL RESEARCH, 1990, 38 (02): : A374 - A374
  • [38] Is Noninvasive Brachial Systolic Blood Pressure an Accurate Estimate of Central Aortic Systolic Blood Pressure?
    Shih, Yuan-Ta
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chuang, Shao-Yuan
    Hu, Wei-Chih
    Chen, Chen-Huan
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (11) : 1283 - 1291
  • [39] USE OF AN AUTOMATED BLOOD-PRESSURE DEVICE AND EXTERNAL AXILLARY PULSE RECORDINGS FOR THE NONINVASIVE DETERMINATION OF END-SYSTOLIC PRESSURE AND SYSTOLIC EJECTION TIME IN INFANTS AND YOUNG-CHILDREN
    COLAN, S
    FUJII, A
    BOROW, K
    SANDERS, S
    PEDIATRIC CARDIOLOGY, 1983, 4 (04) : 311 - 311
  • [40] DIASTOLIC AND SYSTOLIC BLOOD-PRESSURE MEASUREMENTS IN MONKEYS DETERMINED BY A NONINVASIVE TAIL-CUFF TECHNIQUE
    WIESTER, MJ
    ILTIS, R
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1976, 87 (02): : 354 - 361