Adaptive MOEMS Based Micro Pressure Sensor Using Photonic Crystal

被引:0
|
作者
Johnson, O., V [1 ]
Sharan, Preeta [2 ]
机构
[1] Bharathiar Univ, Res & Dev Ctr, Coimbatore, Tamil Nadu, India
[2] Oxford Coll Engn, Dept E&C Engn, Bangalore, Karnataka, India
来源
关键词
Photonic crystal; rod in air; holes in micro cavity; Perfectly Matching layer (PML); pressure; total direct strain; Finite Difference Time Domain (FDTD);
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The Micro Opto Electro Mechanical System (MOEMS) is a most promising cutting-edge technology development that uses recent trends and has huge potential for use in sensing applications. This simulation study describes the Photonic Crystal-(PhC) based micro pressure sensor, which is highly position-sensitive and free from external electromagnetic interference. Functionality of MOEMS in the photonic crystal-based micro pressure sensor is achieved through the movement of the two piston-shaped slab structures analysed in Rods in Air (RIA) and Holes in Slab (HIS) that belong to photonic crystal configurations. Displacement of the micro cavity due to applied pressure gives rise to shifts in wavelength. It is found that for each submicron displacement starting from 0 to 0.25 mm of the piston-shaped slab that is embedded, an approximate range of wavelength shift of 0.0001 for rods in air and for holes in slab configurations occurs. The simulation design shows a remarkable response in terms of intensity shift for desirable range of wavelengths 1.36 mu m to 1.44 mu m for RIA and 1.377 to 1.382 for HIS, thus confirming that wavelength is adaptable. The performance parameters such as Q factor and deflection range for wavelength and intensity are observed for both RIA and HIS configurations and it is found that the sensor with the HIS configuration shows better performance with Q factor of 15897 compared with the sensor with RIA configuration, which remained at a Q factor of 2482. Deformation of structure for applied pressure exhibits a linear relationship with a resonant wavelength shift. Structural variation in relation to wavelength shift exhibits a pressure sensitivity of 58.4 mu m/Pa and 0.98 mu m/mu Pa for each configuration.
引用
收藏
页码:1489 / 1503
页数:15
相关论文
共 50 条
  • [31] High sensitivity photonic crystal pressure sensor
    Biallo, D.
    De Sario, M.
    D'Orazio, A.
    Marrocco, V.
    Petruzzelli, V.
    Vincenti, M. A.
    Prudenzano, F.
    Stomeo, T.
    Grande, M.
    Visimberga, G.
    Cingolani, R.
    De Vittorio, M.
    JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2007, 2
  • [32] Photonic crystal fiber dynamic pressure sensor
    Kaczmarek, Cezary
    Wojcik, Waldemar
    Junisbekov, Muhtar
    2018 XV INTERNATIONAL SCIENTIFIC CONFERENCE ON OPTOELECTRONIC AND ELECTRONIC SENSORS (COE), 2018,
  • [33] Realization of MOEMS pressure sensor using mach zehnder interferometer
    Sumit Kumar Jindal
    Sanjeev Kumar Raghuwanshi
    Ajay Kumar
    Journal of Mechanical Science and Technology, 2015, 29 : 3831 - 3839
  • [34] Realization of MOEMS pressure sensor using mach zehnder interferometer
    Jindal, Sumit Kumar
    Raghuwanshi, Sanjeev Kumar
    Kumar, Ajay
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (09) : 3831 - 3839
  • [35] Photonic crystal fiber micro pressure sensor based on an extrinsic Fabry-Perot interferometer fabricated by femtosecond laser
    Wang, Peng
    Zhang, Liuchao
    Chen, Feifei
    Cao, Zhitao
    PROCEEDINGS OF THE 2017 7TH INTERNATIONAL CONFERENCE ON MANUFACTURING SCIENCE AND ENGINEERING (ICMSE 2017), 2017, 128 : 445 - 450
  • [36] Measurement of interlayer pressure in micro-clearance based on photonic crystal fiber
    Yi, Zhang
    Zhi, Zhuang
    Li Minghai
    Hu Shaoquan
    Rong, Zhang
    Yang, Minghong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (06)
  • [37] High-Sensitivity MOEMS Gyroscope Based on Photonic Crystal Wavelength Modulation
    Yang, Xiuhua
    Xia, Dunzhu
    Fu, Bo
    Li, Jinhui
    Zhao, Jifei
    Chu, Qingbo
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 9489 - 9497
  • [38] Effective pressure sensor using the parity-time symmetric photonic crystal
    Zaky, Zaky A.
    Al-Dossari, M.
    Sharma, Arvind
    Aly, Arafa H.
    PHYSICA SCRIPTA, 2023, 98 (03)
  • [39] Hydrostatic Pressure Sensor Using Two-core Photonic Crystal Fiber
    Liu, Zhengyong
    Tse, Ming-Leung Vincent
    Chen, Daru
    Lu, Chao
    Tam, Hwa-Yaw
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [40] Dual-environment pressure sensor using a photonic-crystal fiber
    Osorio, Jonas H.
    Hayashi, Juliano G.
    Espinel, Yovanny A. V.
    Franco, Marcos A. R.
    Andres, Miguel V.
    Cordeiro, Cristiano M. B.
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157