PEAK DISTORTION EFFECTS OF SURAMIN DUE TO LARGE SYSTEM PEAKS IN BIOANALYSIS USING ION-PAIR ADSORPTION CHROMATOGRAPHY

被引:16
|
作者
FORNSTEDT, T
机构
[1] Department of Analytical Pharmaceutical Chemistry, Uppsala University Biomedical Centre, S-751 23 Uppsala
来源
关键词
D O I
10.1016/0378-4347(93)80376-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sample injections in ion-pair adsorption chromatography lead to changes in the established equilibria of the eluent components at the top of the column, which in turn lead to migrating concentration changes in the column (system peaks). Large system peaks contain big concentration deviations of the mobile phase components compared with the bulk composition in the eluent. Analyte peaks are distorted upon combined elution with large system peaks. In bioanalysis, samples that deviate considerably from the eluent are often injected, resulting in large system peaks. An illustrative example of such analyte peak distortions in bioanalysis is given for the case of suramin, and guidelines are given for avoiding the effects.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 23 条
  • [1] EFFECTS ON ANALYTE PEAK PERFORMANCE BY SEPARATED SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY
    FORNSTEDT, T
    WESTERLUND, D
    JOURNAL OF CHROMATOGRAPHY, 1993, 648 (02): : 315 - 324
  • [2] STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .2. EFFECTS ON ANALYTE PEAK COMPRESSION AND DEFORMATION
    FORNSTEDT, T
    WESTERLUND, D
    SOKOLOWSKI, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (13): : 2645 - 2684
  • [3] STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .4. OPTIMIZATION OF PEAK COMPRESSION
    FORNSTEDT, T
    WESTERLUND, D
    SOKOLOWSKI, A
    JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2): : 93 - 110
  • [4] STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .1. EVALUATION OF ION-PAIR ADSORPTION CONSTANTS AND EFFECTS BY THE INJECTION OF FINITE ANALYTE AMOUNTS
    SOKOLOWSKI, A
    FORNSTEDT, T
    WESTERLUND, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (8-9): : 1629 - 1662
  • [5] STUDIES ON SYSTEM PEAKS IN ION-PAIR ADSORPTION CHROMATOGRAPHY .3. REGULATION OF SYSTEM PEAK GRADIENT RETENTION FOR OBTAINING ANALYTE PEAK COMPRESSION
    FORNSTEDT, T
    WESTERLUND, D
    SOKOLOWSKI, A
    JOURNAL OF CHROMATOGRAPHY, 1990, 506 : 61 - 74
  • [6] BIOANALYSIS OF SURAMIN IN HUMAN PLASMA BY ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TJADEN, UR
    REEUWIJK, HJEM
    VANDERGREEF, J
    PATTYN, G
    DEBRUIJN, EA
    VANOOSTEROM, AT
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 525 (01): : 141 - 149
  • [7] ASPECTS OF SYSTEM PEAKS IN ION-PAIR REVERSED PHASE LIQUID-CHROMATOGRAPHY
    WESTERLUND, D
    ACTA PHARMACEUTICA SUECICA, 1988, 25 (02): : 115 - 116
  • [8] THEORY FOR SYSTEM PEAKS IN ION-PAIR CHROMATOGRAPHY AND ITS APPLICATION TO INDIRECT DETECTION
    STAHLBERG, J
    ALMGREN, M
    ANALYTICAL CHEMISTRY, 1989, 61 (10) : 1109 - 1112
  • [9] EFFECTS OF SYSTEM PEAKS IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOR NOSCAPINE AND METABOLITES
    JOHANSSON, M
    WESTERLUND, D
    JOURNAL OF CHROMATOGRAPHY, 1988, 452 : 241 - 255
  • [10] PEAK COMPRESSION EFFECTS IN ION-PAIR REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF SUBSTITUTED BENZAMIDES
    NILSSON, LB
    WESTERLUND, D
    ANALYTICAL CHEMISTRY, 1985, 57 (09) : 1835 - 1840