VOLUME REPLACEMENT FOLLOWING ACUTE BLEEDING COMPARED TO REPLACEMENT AFTER HEMORRHAGIC SHOCK - EFFECTIVENESS OF DEXTRAN AND BUFFERED SALINE

被引:0
|
作者
RUSH, BF
MOREHOUSE, R
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
引用
收藏
页码:88 / +
页数:1
相关论文
共 50 条
  • [21] Volume replacement with lactated ringer's or 3% hypertonic saline solution during combined experimental hemorrhagic shock and traumatic brain injury
    Pinto, FCG
    Capone-Neto, A
    Prist, R
    Silva, MRE
    Poli-de-Figueiredo, LF
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (04): : 758 - 763
  • [22] Volume replacement with Ringer-lactate is detrimental in severe hemorrhagic shock but protective in moderate hemorrhagic shock: studies in a rat model
    Bjoern Hussmann
    Sven Lendemans
    Herbert de Groot
    Ricarda Rohrig
    Critical Care, 18
  • [23] Volume replacement with Ringer-lactate is detrimental in severe hemorrhagic shock but protective in moderate hemorrhagic shock: studies in a rat model
    Hussmann, Bjoern
    Lendemans, Sven
    de Groot, Herbert
    Rohrig, Ricarda
    CRITICAL CARE, 2014, 18 (01):
  • [24] Acute ethanol intoxication impairs hemodynamic tolerance to hemorrhage and decreases the efficacy of volume replacement in experimental hemorrhagic shock.
    Riera, Luciano
    Garrido, Alejandra G.
    Cruz, Ruy
    Silva, Mauricio Rocha e
    de Figueiredo, Luiz F. Poli
    CRITICAL CARE MEDICINE, 2006, 34 (12) : A16 - A16
  • [25] Small-volume resuscitation from hemorrhagic shock by hypertonic saline dextran - Conceptional basis and historical background
    Kreimeier, U
    Prueckner, S
    EUROPEAN SURGICAL RESEARCH, 2002, 34 (1-2) : 138 - 144
  • [26] Volume replacement with lactated ringer's or 3% hypertonic saline solution during combined experimental hemorrhagic shock and traumatic brain injury - Discussion
    Namias, N
    Tarui, T
    Van De Water, JM
    Capone-Neto, A
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (04): : 763 - 764
  • [27] Preferential effects of low volume versus high volume replacement with crystalloid fluid in a hemorrhagic shock model in pigs
    Martin Ponschab
    Herbert Schöchl
    Claudia Keibl
    Henrik Fischer
    Heinz Redl
    Christoph J. Schlimp
    BMC Anesthesiology, 15
  • [28] Preferential effects of low volume versus high volume replacement with crystalloid fluid in a hemorrhagic shock model in pigs
    Ponschab, Martin
    Schoechl, Herbert
    Keibl, Claudia
    Fischer, Henrik
    Redl, Heinz
    Schlimp, Christoph J.
    BMC ANESTHESIOLOGY, 2015, 15
  • [29] Phospholipid Nanoparticles: A Novel Colloid for Blood Volume Replacement, Reanimation, and Organ Protection in Hemorrhagic Shock
    Shallie, Philemon
    Carpenter, Nathan
    Anamthathmakula, Prashanth
    Kinsey, Danielle
    Moncure, Michael
    Honaryar, Houman
    Ghazali, Hanieh Sadat
    Niroobakhsh, Zahra
    Rodriguez, Juan
    Simpkins, Cuthbert O.
    BIOMEDICINES, 2024, 12 (12)
  • [30] HEMORRHAGIC SHOCK IN THE NEWBORN: ANALYSIS OF BLOOD VOLUME LOSS, REPLACEMENT STRATEGY AND OUTCOME. 921
    Robert P Jankov
    Max Perlman
    Pediatric Research, 1997, 41 (Suppl 4) : 156 - 156