NONINVASIVE MONITORING OF CARDIAC-OUTPUT BY DOPPLER-ECHOCARDIOGRAPHY IN PATIENTS TREATED WITH VOLUME EXPANSION AFTER SUBARACHNOID HEMORRHAGE

被引:14
|
作者
MAYER, SA
SHERMAN, D
FINK, ME
HOMMA, S
SOLOMON, RA
LENNIHAN, L
BECKFORD, A
KLEBANOFF, LM
机构
[1] COLUMBIA PRESBYTERIAN MED CTR,DEPT MED,DIV CARDIOL,NEW YORK,NY 10032
[2] COLUMBIA PRESBYTERIAN MED CTR,DEPT NEUROSURG,NEW YORK,NY 10032
关键词
SUBARACHNOID HEMORRHAGE; CARDIAC OUTPUT; ECHOCARDIOGRAPHY; DOPPLER; PULMONARY ARTERY CATHETER; THERMODILUTION; VASOSPASM; ALBUMIN; MONITORING; PHYSIOLOGICAL; CRITICAL ILLNESS;
D O I
10.1097/00003246-199509000-00005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess the validity and potential clinical utility of cardiac output monitoring using Doppler echocardiography in patients treated with volume expansion after subarachnoid hemorrhage, Design: Observational study of patients in a randomized, clinical trial, Setting: Neurologic intensive care unit, Patients: Simultaneous, blinded measurements of cardiac output by thermodilution and Doppler echocardiography were performed in 48 patients 1 or 2 days after aneurysmal clipping, Follow-up Doppler echocardiography was performed an average of 3.9 days later (range 3 to 6) in 15 patients assigned to normovolemia and 24 patients assigned to hypervolemia, Intervention: Patients received supplemental 5% albumin in order to maintain increased (hypervolemia) or normal (normovolemia) cardiac filling pressures, Measurements and Main Results: The overall degree of correlation between the two measures was moderate (r = .67, r(2) = .45, p < .0001), Bias and precision calculations (-0.75 +/- 1.34 L/min) showed a tendency for Doppler echocardiography to underestimate thermodilution, particularly when cardiac output was very high, Although hypervolemia patients received more 5% albumin than normovolemia patients, mean percent change in Doppler echocardiography cardiac output did not differ between the two groups, Multiple regression analysis showed that the percent change in Doppler echocardiography cardiac output correlated strongly with changes in heart rate (p < .0001), but not with daily net fluid balance or 5% albumin administration, Conclusions: Agreement was poor between Doppler echocardiography and thermodilution measurements of cardiac output, and trends reflected variations in heart rate rather than fluid status, Monitoring of cardiac output by this technique cannot be recommended in patients treated with volume expansion after subarachnoid hemorrhage.
引用
收藏
页码:1470 / 1474
页数:5
相关论文
共 50 条
  • [31] NONINVASIVE MONITORING OF CARDIAC-OUTPUT CHANGES DURING AORTIC CROSS-CLAMPING FOR INFRARENAL RECONSTRUCTION - A NEW TECHNIQUE USING SUPRASTERNAL DOPPLER-DERIVED CARDIAC-OUTPUT
    DAVIES, JN
    RANABOLDO, CJ
    NEVIN, M
    NORMAN, J
    CROSSE, MM
    WEBSTER, JHH
    CHANT, ADB
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (05): : 467 - 470
  • [32] CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE
    BERNSTEIN, DP
    CRITICAL CARE MEDICINE, 1986, 14 (10) : 898 - 901
  • [33] Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output
    van der Spoel, Anna G. E.
    Voogel, Albertus J.
    Folkers, Anja
    Boer, Christa
    Bouwman, R. Arthur
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (04) : 304 - 309
  • [35] Comparison of noninvasive continuous arterial waveform analysis (Nexfin HD) with transthoracic doppler echocardiography for monitoring of cardiac output
    Bouwman, R. A.
    van der Spoel, A. G. E.
    Folkers, A.
    Voogel, B. J.
    Boer, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 67 - 67
  • [36] Estimation of Stroke Volume and Aortic Valve Area in Patients With Aortic Stenosis: A Comparison of Doppler-Echocardiography and Cardiac Magnetic Resonance
    Capoulade, Romain
    Le Ven, Florent
    Garcia, Julio
    Tastet, Lionel
    Dahou, Abdellaziz
    Dumesnil, Jean G.
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Pibarot, Philippe
    CIRCULATION, 2014, 130
  • [37] The Relationships Between BNP and Neurocardiac Injury Severity, Noninvasive Cardiac Output, and Outcomes After Aneurysmal Subarachnoid Hemorrhage
    McAteer, Amber
    Hravnak, Marilyn
    Chang, Yuefang
    Crago, Elizabeth A.
    Gallek, Matthew J.
    Yousef, Khalil M.
    BIOLOGICAL RESEARCH FOR NURSING, 2017, 19 (05) : 531 - 537
  • [38] EVALUATION OF CARDIAC-OUTPUT BY DOPPLER-ECHOCARDIOGRAPHY - CORRELATION OF AORTIC, PULMONARY AND MITRAL RING FLOW-RATES - STUDY OF 103 SUBJECTS FREE OF VALVE LEAK
    DENIS, B
    PETIT, L
    VANZETTO, G
    BERTRAND, B
    HADJIAN, O
    CONTARD, M
    DEFAYE, P
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1992, 41 (05): : 253 - 257
  • [39] CONTINUOUS VS INJECTATE CARDIAC-OUTPUT MONITORING BEFORE AND AFTER EXTUBATION OF CARDIAC SURGICAL PATIENTS
    BOTTIGER, BW
    SODER, M
    RAUCH, H
    BOHRER, H
    MOTSCH, J
    MARTIN, E
    ANESTHESIOLOGY, 1994, 81 (3A) : A513 - A513
  • [40] THE EFFECTS OF DOBUTAMINE, NITRO-PRUSSIDE, OR VOLUME EXPANSION ON CARDIAC-OUTPUT AND LUNG WATER AFTER CPPV
    NOBLE, WH
    KAY, JC
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (01) : 48 - 56