COMPARISON OF CONTINUOUS SINGLE-LAYER POLYPROPYLENE ANASTOMOSIS WITH DOUBLE-LAYER AND STAPLED ANASTOMOSES IN ELECTIVE COLON RESECTIONS

被引:2
|
作者
CERALDI, CM
RYPINS, EB
MONAHAN, M
CHANG, B
SARFEH, IJ
机构
[1] UNIV CALIF IRVINE,DEPT SURG,IRVINE,CA 92717
[2] VET ADM MED CTR,DEPT SURG,LONG BEACH,CA 90822
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The documented leak rate of the continuous single layer polypropylene (CSLP) anastomosis in elective colon resection is 0-6 per cent. It is more cost effective than stapling (S), and should be faster and easier to perform than the double-layer (DL) technique. However, there have been no reported series comparing the outcome of the CSLP anastomosis with the DL and S techniques. We reviewed the charts of 100 patients with elective colon resections. Eighty-four had data sufficient for analysis. There were 44 CSLP, 21 DL, and 19 S. The groups were comparable with respect to 12 preoperative variables. Proportionately more large-small bowel anastomoses were performed in the S group, and no patient in the S group was actively taking steroids. Clinical outcome was assessed. All leaks were clinically apparent and documented with contrast enema or laparotomy. The leak rate for the CSLP was 6.8 per cent (3/44). Two of the three patients with leaks were taking steroids. There were two leaks in the DL group (9.5%), one of which was taking steroids, and no leaks in the S group. The difference in leak rate between the three groups was not statistically significant. The average cost for CSLP at our institution is $4.00 compared with $8.00 and $35.00 for the DL and S, respectively. We conclude that the CSLP is a reasonable and safe alternative to DL and S anastomoses.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [41] Thermocapillary flow in double-layer fluid structures: An effective single-layer model
    Gupta, NR
    Haj-Hariri, H
    Borhan, A
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2006, 293 (01) : 158 - 171
  • [42] CLOSURE OF THE ABDOMINAL WOUND WITH SINGLE-LAYER AND DOUBLE-LAYER TECHNIQUE - ANIMAL STUDIES
    NILSSON, T
    ACTA CHIRURGICA SCANDINAVICA, 1981, 147 (06): : 399 - 403
  • [43] Single-layer continuous anastomosis in gastrointestinal surgery: A prospective audit
    AhChong, AK
    Chiu, KM
    Law, IC
    Chu, MK
    Yip, AWC
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (01): : 34 - 36
  • [44] Continuous single-layer anastomoses with monofilament poliglecaprone sutures in abdominal surgery
    Samel, ST
    Heinrich, A
    Becker, H
    Post, S
    EUROPEAN JOURNAL OF SURGERY, 1999, 165 (07) : 710 - 711
  • [45] PROSPECTIVE EVALUATION OF SUTURED, CONTINUOUS, AND INTERRUPTED SINGLE-LAYER COLONIC ANASTOMOSES
    DEEN, KI
    SMART, PJG
    EUROPEAN JOURNAL OF SURGERY, 1995, 161 (10) : 751 - 753
  • [46] COMPARISON OF SINGLE WITH DOUBLE LAYER INTESTINAL ANASTOMOSIS
    Mahmood, Saira
    Ali, Sana
    Atta, Sidra
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (12): : 15614 - 15620
  • [47] K-SPACE PROPERTIES OF CLASSICAL SINGLE-LAYER AND DOUBLE-LAYER POTENTIALS AND THEIR DERIVATIVES
    DESANTO, JA
    WAVE MOTION, 1993, 17 (02) : 143 - 159
  • [48] Optoelectronic properties of single-layer, double-layer, and bulk tin sulfide: A theoretical study
    Tritsaris, Georgios A.
    Malone, Brad D.
    Kaxiras, Efthimios
    JOURNAL OF APPLIED PHYSICS, 2013, 113 (23)
  • [49] Equivalent Single-layer Power Cable Sheath for Transient Modeling of Double-layer Sheaths
    de Bruyn, B. J. H.
    Wu, L.
    Wouters, P. A. A. F.
    Steennis, E. F.
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [50] Nitinol double-layer stent versus closed single-layer stent: a systematic review
    Silvinato, Antonio
    Floriano, Idevaldo
    Bernardo, Wanderley
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2022, 68 (11): : 1490 - 1495