DETERMINATION OF BENTAZEPAM BY DIFFERENTIAL PULSE POLAROGRAPHY AND ADSORPTIVE STRIPPING VOLTAMMETRY

被引:5
|
作者
HERNANDEZ, L
HERNANDEZ, P
LORENZO, E
GONZALEZ, C
GONZALEZ, I
机构
[1] UNIV AUTONOMA MADRID,DEPT CHEM,E-28049 MADRID,SPAIN
[2] UNIV SALAMANCA,DEPT ANALYT CHEM,SALAMANCA,SPAIN
来源
关键词
D O I
10.1007/BF00332257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the determination of Bentazepam using DPP and ADSV with DP. Bentazepam is determined in buffer Britton-Robinson 0.04 mol l-1 at pH 9 with detection limits of 3.1×10-9 mol/l and a relative standard deviation of 0.8 DPP was used to determine Bentazepam in Tiadipona, the commercial product. ADSV was used to determine Bentazepam in urine with a detection limit of 2.7 ng ml-1 (accumulation time 5 min) and a relative standard deviation of 1.5%. © 1990 Springer-Verlag.
引用
收藏
页码:222 / 225
页数:4
相关论文
共 50 条
  • [41] DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR MERCURY DETERMINATION
    Verestiuc, Paul C.
    Tucaliuc, Oana-Maria
    Breaban, Iuliana G.
    Cretescu, Igor
    Nemtoi, Gheorghe
    [J]. ACTA CHEMICA IASI, 2015, 23 (01) : 13 - 24
  • [42] Determination of palladium by adsorptive stripping voltammetry
    Georgieva, M
    Pihlar, B
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (07): : 874 - 880
  • [43] DETERMINATION OF TRICHLOROBIPHENYL BY ADSORPTIVE STRIPPING VOLTAMMETRY
    LAM, NK
    KOPANICA, M
    [J]. ANALYTICA CHIMICA ACTA, 1984, 161 (JUL) : 315 - 324
  • [44] Determination of trace titanium(IV) by differential pulse catalytic adsorptive stripping voltammetry at a bismuth film electrode
    Cui, Hong
    Sun, Wenhua
    Li, Xiangjun
    Zou, Hong
    Yuan, Zhuobin
    [J]. ANALYTICAL METHODS, 2013, 5 (07) : 1784 - 1789
  • [45] DETERMINATION OF BILIRUBIN BY ADSORPTIVE STRIPPING VOLTAMMETRY
    WANG, J
    LUO, DB
    FARIAS, PAM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 185 (01): : 61 - 71
  • [46] Determination of palladium by adsorptive stripping voltammetry
    Marija Georgieva
    B. Pihlar
    [J]. Fresenius' Journal of Analytical Chemistry, 1997, 357 : 874 - 880
  • [47] Determination of gallium by adsorptive stripping voltammetry
    González, MJG
    Renedo, OD
    Lomillo, MAA
    Martínez, MJA
    [J]. TALANTA, 2004, 62 (03) : 457 - 462
  • [48] DETERMINATION OF CEFTRIAXONE IN AQUEOUS-HUMOR AND SERUM SAMPLES BY DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRY
    ALTINOZ, S
    OZER, D
    TEMIZER, A
    YUKSEL, N
    [J]. ANALYST, 1994, 119 (07) : 1575 - 1577
  • [49] Differential Pulse Adsorptive Cathodic Stripping Voltammetry for the Simultaneous Determination of Pb and Zn in Seawater Using Calcon
    Pardi, H.
    Deswati
    Edelwis, T. W.
    Willian, N.
    Fitriyah, D.
    [J]. PORTUGALIAE ELECTROCHIMICA ACTA, 2021, 39 (01) : 45 - 57
  • [50] Determination of apo-metallothionein using adsorptive transfer stripping technique in connection with differential pulse voltammetry
    Adam, Vojtech
    Krizkova, Sona
    Zitka, Ondrej
    Trnkova, Libuse
    Petrlova, Jitka
    Beklova, Miroslava
    Kizek, Rene
    [J]. ELECTROANALYSIS, 2007, 19 (2-3) : 339 - 347