FOCAL COMPENSATORY ENLARGEMENT OF HUMAN ARTERIES IN RESPONSE TO PROGRESSIVE ATHEROSCLEROSIS - IN-VIVO DOCUMENTATION USING INTRAVASCULAR ULTRASOUND

被引:178
|
作者
LOSORDO, DW [1 ]
ROSENFIELD, K [1 ]
KAUFMAN, J [1 ]
PIECZEK, A [1 ]
ISNER, JM [1 ]
机构
[1] TUFTS UNIV,ST ELIZABETHS HOSP,SCH MED,DEPT BIOMED RES,BOSTON,MA 02111
关键词
ATHEROSCLEROSIS; ULTRASOUND; ARTERIES;
D O I
10.1161/01.CIR.89.6.2570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous postmortem studies have demonstrated compensatory enlargement of atherosclerotic arteries in animal models and patients. Conclusions regarding these changes were drawn based on a comparison of the dimensions of diseased arteries in one group of subjects with the dimensions of normal arteries in another group. This method admits potential confounding variables, such as demographics and other disease states, which might also have an impact on arterial size. Methods and Results Using intravascular ultrasound, we studied a total of 62 paired, adjacent normal and diseased sites in the superficial femoral arteries of 20 patients undergoing peripheral vascular interventions. Morphological assessment was performed using a computer-based image analysis system. Measurements were made of the cross-sectional area of the arterial lumen, the atherosclerotic plaque, and the outer border of the artery. These dimensions were then compared to determine the effects of progressive atherosclerosis on arterial morphology. Luminal cross-sectional area decreased from 21.1+/-2.2 mm(2) in normal segments to 16.7+/-0.8 mm(2) (P=.0001) in adjacent atherosclerotic segments. Similarly, minimal luminal diameter decreased from 5.7+/-0.2 to 5.0+/-0.1 mm(2), and maximal luminal diameter decreased from 6.2+/-0.2 to 5.7+/-0.2 mm(2). At these same sites, total arterial area was 32.9+/-1.6 and 37.9+/-1.9 mm(2) (P=.0001) in normal and diseased segments, respectively. Minimal and maximal arterial diameters demonstrated similar increases (7.3+/-0.2 to 7.7+/-0.2 mm(2) [P=.0015] and 7.6+/-0.2 to 8.3+/-0.2 mm(2) [P=.0001], respectively). Regression analysis disclosed correlation of the cross-sectional area of plaque to the total arterial area (R=.70, P=.0001). Conclusions Human arteries enlarge in response to progressive atherosclerosis. This compensatory mechanism results in an increase in arterial size that is proportionate to the cross-sectional area of plaque that has accumulated in the vessel. Intravascular ultrasound demonstrates that this process is focal compensatory enlargement at discrete sites of atherosclerotic narrowing immediately adjacent to more normal areas in which arterial size is smaller.
引用
收藏
页码:2570 / 2577
页数:8
相关论文
共 50 条
  • [41] In vivo characterization of atherosclerotic plaque of human carotid arteries with histopathological correlation using ARFI ultrasound
    Czemuszcwiez, Tomasz J.
    IIomcistcr, Jonathon W.
    Caughey, Melissa C.
    Farber, Mark A.
    Fulton, Joseph J.
    Ford, Peter F.
    Marston, William A.
    Vallabhaneni, Raghuveer
    Nichols, Timothy C.
    Gallippi, Caterina M.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1794 - 1797
  • [42] CORRELATION OF VASA VASORUM AND PLAQUE PROGRESSION AND RESPONSE TO ATORVASTATIN THERAPY AN A RABBIT MODEL OF ATHEROSCLEROSIS: IN VIVO INTRAVASCULAR ULTRASOUND AND CONTRAST-ENHANCED ULTRASOUND IMAGING STUDY
    Tian, JinWei
    Hu, Sining
    Jia, Haibo
    Hou, Jingbo
    Zhang, Shaosong
    Yu, Bo
    Jang, Ik-Kyung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1072 - E1072
  • [43] Commentary: Plaque burden estimated from optical coherence tomography with Deep Learning: In-vivo validation using coregistered intravascular ultrasound
    Alasnag, Mirvat
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 101 (02) : 297 - 298
  • [44] Fluorescence Lifetime Imaging Combined with Conventional Intravascular Ultrasound for Enhanced Assessment of Atherosclerotic Plaques: an Ex Vivo Study in Human Coronary Arteries
    Fatakdawala, Hussain
    Gorpas, Dimitris
    Bishop, John W.
    Bec, Julien
    Ma, Dinglong
    Southard, Jeffrey A.
    Margulies, Kenneth B.
    Marcu, Laura
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2015, 8 (04) : 253 - 263
  • [45] Fluorescence Lifetime Imaging Combined with Conventional Intravascular Ultrasound for Enhanced Assessment of Atherosclerotic Plaques: an Ex Vivo Study in Human Coronary Arteries
    Hussain Fatakdawala
    Dimitris Gorpas
    John W. Bishop
    Julien Bec
    Dinglong Ma
    Jeffrey A. Southard
    Kenneth B. Margulies
    Laura Marcu
    Journal of Cardiovascular Translational Research, 2015, 8 : 253 - 263
  • [46] Is intravascular ultrasound better than quantitative coronary angiography for assessment of late in-stent restenosis? In-vivo human correlation and methodological implications
    Prati, F
    Pawlowski, T
    Gziut, A
    Manzoli, A
    Pappalardo, A
    Caradonna, E
    Kwiatkowski, P
    Boccanelli, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 638 - 638
  • [47] In-vivo Assessment of Wall Stiffness and Wall Shear Stress in Human Coronary Arteries using Computed Tomography Angiography
    Katranas, Sotirios
    Kelekis, Anastasios
    Theodoridis, Teodoros
    Tzanis, Alexandros
    Chatzizisis, Yiannis
    Giannoglou, George
    CIRCULATION, 2010, 122 (21)
  • [48] In-vivo thrombolysis using a high-frequency intravascular transducer-tipped ultrasound catheter and local drug delivery in a canine model
    Atar, S
    Luo, H
    Nagai, T
    Sahm, RA
    McCreery, T
    Siegel, R
    CIRCULATION, 1998, 98 (17) : 398 - 399
  • [49] Performance assessment of pulse wave imaging using conventional ultrasound in canine aortas ex vivo and normal human arteries in vivo
    Ronny X. Li
    William Qaqish
    Elisa E. Konofagou
    Artery Research, 2015, 11 : 19 - 28
  • [50] Performance assessment of pulse wave imaging using conventional ultrasound in canine aortas ex vivo and normal human arteries in vivo
    Li, Ronny X.
    Qaqish, William
    Konofagou, Elisa E.
    ARTERY RESEARCH, 2015, 11 : 19 - 28