FOCAL COMPENSATORY ENLARGEMENT OF HUMAN ARTERIES IN RESPONSE TO PROGRESSIVE ATHEROSCLEROSIS - IN-VIVO DOCUMENTATION USING INTRAVASCULAR ULTRASOUND

被引:178
|
作者
LOSORDO, DW [1 ]
ROSENFIELD, K [1 ]
KAUFMAN, J [1 ]
PIECZEK, A [1 ]
ISNER, JM [1 ]
机构
[1] TUFTS UNIV,ST ELIZABETHS HOSP,SCH MED,DEPT BIOMED RES,BOSTON,MA 02111
关键词
ATHEROSCLEROSIS; ULTRASOUND; ARTERIES;
D O I
10.1161/01.CIR.89.6.2570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous postmortem studies have demonstrated compensatory enlargement of atherosclerotic arteries in animal models and patients. Conclusions regarding these changes were drawn based on a comparison of the dimensions of diseased arteries in one group of subjects with the dimensions of normal arteries in another group. This method admits potential confounding variables, such as demographics and other disease states, which might also have an impact on arterial size. Methods and Results Using intravascular ultrasound, we studied a total of 62 paired, adjacent normal and diseased sites in the superficial femoral arteries of 20 patients undergoing peripheral vascular interventions. Morphological assessment was performed using a computer-based image analysis system. Measurements were made of the cross-sectional area of the arterial lumen, the atherosclerotic plaque, and the outer border of the artery. These dimensions were then compared to determine the effects of progressive atherosclerosis on arterial morphology. Luminal cross-sectional area decreased from 21.1+/-2.2 mm(2) in normal segments to 16.7+/-0.8 mm(2) (P=.0001) in adjacent atherosclerotic segments. Similarly, minimal luminal diameter decreased from 5.7+/-0.2 to 5.0+/-0.1 mm(2), and maximal luminal diameter decreased from 6.2+/-0.2 to 5.7+/-0.2 mm(2). At these same sites, total arterial area was 32.9+/-1.6 and 37.9+/-1.9 mm(2) (P=.0001) in normal and diseased segments, respectively. Minimal and maximal arterial diameters demonstrated similar increases (7.3+/-0.2 to 7.7+/-0.2 mm(2) [P=.0015] and 7.6+/-0.2 to 8.3+/-0.2 mm(2) [P=.0001], respectively). Regression analysis disclosed correlation of the cross-sectional area of plaque to the total arterial area (R=.70, P=.0001). Conclusions Human arteries enlarge in response to progressive atherosclerosis. This compensatory mechanism results in an increase in arterial size that is proportionate to the cross-sectional area of plaque that has accumulated in the vessel. Intravascular ultrasound demonstrates that this process is focal compensatory enlargement at discrete sites of atherosclerotic narrowing immediately adjacent to more normal areas in which arterial size is smaller.
引用
收藏
页码:2570 / 2577
页数:8
相关论文
共 50 条
  • [1] DEVELOPMENT OF CORONARY COMPENSATORY ENLARGEMENT IN-VIVO - SEQUENTIAL ASSESSMENTS WITH INTRAVASCULAR ULTRASOUND
    WEISSMAN, NJ
    MENDELSOHN, FO
    PALACIOS, IF
    WEYMAN, AE
    AMERICAN HEART JOURNAL, 1995, 130 (06) : 1283 - 1285
  • [2] Compensatory enlargement of angiographically normal coronary segments in patients with coronary artery disease - In vivo documentation using intravascular ultrasound
    Nakamura, Y
    Takemori, H
    Shiraishi, K
    Inoki, I
    Sakagami, M
    Shimakura, A
    Usuda, K
    Kubota, K
    Takata, S
    Kobayashi, KI
    ANGIOLOGY, 1996, 47 (08) : 775 - 781
  • [3] LACK OF COMPENSATORY ENLARGEMENT IN CORONARY ATHEROSCLEROSIS IS RESPONSIBLE FOR SEVERE STENOSES - AN IN-VIVO INTRACORONARY ULTRASOUND STUDY
    GAYLE, DD
    BRADEN, GA
    CLINICAL RESEARCH, 1993, 41 (04): : A720 - A720
  • [4] Compensatory enlargement of human coronary arteries during progression of atherosclerosis is unrelated to atheroma burden: serial intravascular ultrasound observations from the REVERSAL trial
    Sipahi, Ilke
    Tuzcu, E. Murat
    Schoenhagen, Paul
    Nicholls, Stephen J.
    Ozduran, Volkan
    Kapadia, Samir
    Nissen, Steven E.
    EUROPEAN HEART JOURNAL, 2006, 27 (14) : 1664 - 1670
  • [5] IN-VIVO DIAGNOSIS OF PULMONARY ATHEROSCLEROSIS - ROLE OF INTRAVASCULAR ULTRASOUND
    KRAVITZ, KD
    SCHARF, GR
    CHANDRASEKARAN, K
    CHEST, 1994, 106 (02) : 632 - 634
  • [6] In vivo validation of compensatory enlargement of coronary artery: Serial intravascular ultrasound assessment
    Takagi, T
    Yoshida, K
    Akasaka, T
    Kaji, S
    CIRCULATION, 1997, 96 (08) : 3289 - 3289
  • [7] Contribution of inadequate compensatory enlargement to development of human coronary artery stenosis: An in vivo intravascular ultrasound study
    Nishioka, T
    Luo, H
    Eigler, NL
    Berglund, H
    Kim, CJ
    Siegel, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) : 1571 - 1576
  • [8] Absence of focal compensatory enlargement or constriction in diseased human coronary saphenous vein bypass grafts - An intravascular ultrasound study
    Nishioka, T
    Berglund, H
    Eigler, NL
    Kim, CJ
    Tabak, SW
    Siegel, RJ
    CIRCULATION, 1996, 93 (04) : 683 - 690
  • [9] IN-VIVO ASSESSMENT BY INTRAVASCULAR ULTRASOUND AT ENLARGEMENT IN SAPHENOUS-VEIN BYPASS GRAFTS
    MENDELSOHN, FO
    FOSTER, GP
    PALACIOS, IF
    WEYMAN, AE
    WEISSMAN, NJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (14): : 1066 - +
  • [10] Impaired compensatory coronary artery enlargement in atherosclerosis contributes to the development of coronary artery stenosis in diabetic patients - An in vivo intravascular ultrasound study
    Vavuranakis, M
    Stefanadis, C
    Toutouzas, K
    Pitsavos, C
    Spanos, V
    Toutouzas, P
    EUROPEAN HEART JOURNAL, 1997, 18 (07) : 1090 - 1094