The paper describes a nanosecond current transducer which is a hybrid between a shunt and a Rogowski loop. Its readings are independent of the distribution of the current to be measured, and it does not distort the electromagnetic field where it is located. The transducer was designed to measure large currents (tens of kiloamperes) with rise times of tens of nanoseconds and fall times of tens of microseconds.
引用
收藏
页码:422 / 424
页数:3
相关论文
共 50 条
  • [41] Delay loop current control methods of Shunt Active Power Filter
    Liu, Gui-ying
    Su, Shi-ping
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 105 - 108
  • [42] Current Loop Control Strategy Research for Shunt Active Power Filter
    Chen Yuqing
    Zhang Kehu
    Ji Zhaojun
    Zhen Hongfen
    Kong Feng
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2009, : 698 - +
  • [43] High performance Rogowski current transducers
    Ray, WF
    Hewson, CR
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3083 - 3090
  • [44] The Use of Rogowski Coils in Current Measurement
    Barber, John P.
    2014 17TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC LAUNCH TECHNOLOGY (EML), 2014,
  • [45] Effect of Shielding on Rogowski Coil Transducer Performance and the Equivalent Circuit Model
    Ibrahim, Mohamed E.
    Mohamed, Nourhan A.
    El-Morshedy, Ahdab
    El-Shahat, Mohammed
    IEEE SENSORS JOURNAL, 2022, 22 (24) : 24036 - 24043
  • [46] Control to reduce leading current in a Shunt Hybrid Power Filter
    Lamich, Manuel
    Balcells, Josep
    Gonzalez, David
    Gago, Xavier
    Jaen, Carles
    Castillo, Jose Luis
    CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 73 - 78
  • [47] DISCHARGE CURRENT MEASUREMENT BY ROGOWSKI LOOPS
    OKUN, IZ
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (06): : 1406 - &
  • [48] SHORT-PULSE ROGOWSKI LOOP WITH METAL CORE
    GERASIMOV, AI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (01) : 151 - 153
  • [49] Analysis and Compensation of Phase Shift Errors of an Open-Loop Current Transducer Considering Eddy Current
    Kim, Kiseok
    Kim, Yoonjae
    Han, Ji-Hoon
    Hong, Sun-Ki
    IEEE ACCESS, 2024, 12 : 62730 - 62737
  • [50] CHARGE-DIGITAL NANOSECOND PULSE TRANSDUCER
    BUSHNIN, YB
    DENISENKO, AA
    DUNAITSEV, AF
    SOLDATOV, MM
    SYTIN, AN
    YAKIMCHUK, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1980, 23 (03) : 625 - 629