INVESTIGATION OF THE RELATIVE SURFACE DOSE FROM LIPOWITZ-METAL TISSUE COMPENSATORS FOR 24-MV AND 6-MV PHOTON BEAMS

被引:11
|
作者
CARDARELLI, GA [1 ]
RAO, SN [1 ]
CAIL, D [1 ]
机构
[1] UNIV HOSP BOSTON, DEPT RADIAT PHYS, BOSTON, MA 02118 USA
关键词
D O I
10.1118/1.596671
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our radiation therapy department has acquired a tissue compensator system for construction of patient-specific Lipowitz-metal tissue compensators. Since the arrival of this apparatus its use has been limited due to the observance of marked skin reactions located directly beneath the area of the compensator. Although there has been extensive literature on the dose distribution of these metal compensators, there is little data on the effects to the skin for energies greater than 10 MV. Determination of the relative surface dose from Lipowitz-metal tissue compensators is herein investigated for 24- and 6-MV x-ray beams. Effects of field size, source-to-skin distance and thickness of compensator are evaluated as well as the effect of the Lexan tray which supports the compensator during treatment.
引用
收藏
页码:282 / 287
页数:6
相关论文
共 29 条
  • [21] Equivalent square formula for determining the surface dose of rectangular field from 6 MV therapeutic photon beam
    Apipunyasopon, Lukkana
    Srisatit, Somyot
    Phaisangittisakul, Nakorn
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (05): : 196 - 204
  • [22] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Chung Il Lee
    Sei-Chul Yoon
    Jae Won Shin
    Seung-Woo Hong
    Tae Suk Suh
    Kyung Joo Min
    Sang Deok Lee
    Su Mi Chung
    Jae-Yong Jung
    Journal of the Korean Physical Society, 2015, 66 : 1308 - 1316
  • [23] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Lee, Chung Il
    Yoon, Sei-Chul
    Shin, Jae Won
    Hong, Seung-Woo
    Suh, Tae Suk
    Min, Kyung Joo
    Lee, Sang Deok
    Chung, Su Mi
    Jung, Jae-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (08) : 1308 - 1316
  • [24] Influence of standard RF coil materials on surface and buildup dose from a 6 MV photon beam in magnetic field
    Ghila, A.
    Fallone, B. G.
    Rathee, S.
    MEDICAL PHYSICS, 2016, 43 (11) : 5808 - 5816
  • [25] Verification of Acurose XB Dose Calculation Algorithm at Air Cavity-Tissue Interface Using Film Measurement for Small Fields of 6-MV Flattening Filter-Free Beams
    Kang, S.
    Chung, J.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3521 - 3521
  • [26] Surface dose for five telecobalt machines, 6MV photon beam from four linear accelerators and a Hi-Art TomoTherapy
    Kinhikar, Rajesh A.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (05) : 381 - 384
  • [27] INVESTIGATION OF EBT3 RADIOCHROMIC FILM RESPONSE IN A HIGH-DOSE RANGE OF 6 MV PHOTON AND 6 MEV ELECTRON BEAMS USING A THREE-COLOR FLATBED SCANNER
    Duruer, Kerem
    Etiz, Durmus
    Yucel, Haluk
    EAST EUROPEAN JOURNAL OF PHYSICS, 2020, (03): : 11 - 18
  • [28] Investigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber
    Kesen, Nazmiye Donmez
    Akbas, Ugur
    Koksal, Canan
    Bilge, Hatice
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (02) : 361 - 369
  • [29] The Investigation of The Anisotropic Analytical Algorithm (AAA) and the Acuros XB (AXB) Dose Calculation Algorithms Accuracy in Surface and Buildup Region for 6 MV Photon Beam Using Gafchromic EBT3 Film
    Donmez Kesen, Nazmiye
    Koksal Akbas, Canan
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (03): : 365 - 372