EFFECT OF ABRUPTLY INCREASED INTRATHORACIC PRESSURE ON CORONARY BLOOD-FLOW VELOCITY IN PATIENTS

被引:20
|
作者
KERN, MJ
GUDIPATI, C
TATINENI, S
AGUIRRE, F
SEROTA, H
DELIGONUL, U
机构
关键词
D O I
10.1016/S0002-8703(05)80324-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the effects of abruptly increased intrathoracic pressure on coronary blood flow, arterial pressure, heart rate, and intracoronary Doppler blood flow velocity were measured continuously during cough(s) and again during the four phases of the Valsalva maneuver in 14 patients. Coughing significantly increased the systolic pressure (137±25 to 176±30 mm Hg), diastolic pressure (72±10 to 84±18 mm Hg), and arterial pulse pressure (65±27 to 92±35 mm Hg), with no change in heart rate. The mean coronary flow velocity decreased (17±10 to 14±12 cm/sec, p<0.03). During the Valsalva maneuver, despite marked reduction in the mean arterial pressure during phase III (96±12 to 68±14 mm Hg, p<0.05), the reduction of coronary blood flow velocity did not achieve statistical significance. These data demonstrate that neither type of abrupt physiologic increase in intrathoracic pressure enhances coronary blood flow. Coughing does not improve coronary perfusion pressures or flow velocity, despite marked increases in arterial diastolic pressure. The Valsalva maneuver, for the most part, does not significantly alter coronary blood flow velocity. © 1990 Mosby-Year Book, Inc.
引用
收藏
页码:863 / 870
页数:8
相关论文
共 50 条
  • [21] RELATIONSHIP BETWEEN SYMPTOMS AND CORONARY BLOOD-FLOW VELOCITY IN PATIENTS WITH AORTIC-STENOSIS
    OMRAN, H
    FEHSKE, W
    CIRCULATION, 1994, 90 (04) : 116 - 116
  • [22] MEASUREMENTS OF CORONARY SINUS BLOOD-FLOW VELOCITY BY DOPPLER CATHETERS
    TEBBENJOHANNS, J
    NITSCH, J
    LUDERITZ, B
    ZEITSCHRIFT FUR KARDIOLOGIE, 1992, 81 (03): : 170 - 175
  • [23] SPONTANEOUS ALTERATIONS IN CORONARY BLOOD-FLOW VELOCITY BEFORE AND AFTER CORONARY ANGIOPLASTY IN PATIENTS WITH SEVERE ANGINA
    EICHHORN, EJ
    GRAYBURN, PA
    WILLARD, JE
    ANDERSON, HV
    BEDOTTO, JB
    CARRY, M
    KAHN, JK
    WILLERSON, JT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (01) : 43 - 52
  • [24] INTRAMYOCARDIAL PRESSURE - EFFECT OF PRELOAD ON TRANSMURAL DISTRIBUTION OF SYSTOLIC CORONARY BLOOD-FLOW
    ARCHIE, JP
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 35 (06): : 904 - 911
  • [25] REGIONAL CORONARY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN PATIENTS WITH ANGIOGRAPHICALLY NORMAL CORONARY-ARTERIES
    KERN, MJ
    TATINENI, S
    GUDIPATI, C
    AGUIRRE, F
    RING, ME
    SEROTA, H
    DELIGONUL, U
    CORONARY ARTERY DISEASE, 1990, 1 (05) : 579 - 589
  • [26] NEW MODULAR SYSTEM FOR THE DETERMINATION OF CORONARY BLOOD-FLOW VELOCITY
    BAUMGART, D
    HAUDE, M
    GE, JB
    GORGE, G
    LIU, GQ
    ERBEL, R
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 35 (04): : 378 - 379
  • [27] ACUTE CHANGES IN BLOOD-FLOW VELOCITY WITH SUCCESSFUL CORONARY ANGIOPLASTY
    SIBLEY, D
    BULLE, T
    BAXLEY, W
    DEAN, L
    CHANDLER, J
    WHITLOW, P
    CIRCULATION, 1986, 74 (04) : 193 - 193
  • [28] A METHOD FOR CONTINUOUSLY ASSESSING CORONARY BLOOD-FLOW VELOCITY IN THE RAT
    WANGLER, RD
    PETERS, KG
    LAUGHLIN, DE
    TOMANEK, RJ
    MARCUS, ML
    AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (06): : H816 - H820
  • [29] INCREASED VISCERAL BLOOD-FLOW IN BURN PATIENTS
    AULICK, LH
    WILMORE, DW
    GOODWIN, CW
    BECKER, RA
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 902 - 902
  • [30] ESTIMATION OF INTRAMYOCARDIAL PRESSURE AND CORONARY BLOOD-FLOW DISTRIBUTION
    SUN, Y
    GEWIRTZ, H
    AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (03): : H664 - H672