MONITORING REJECTION AFTER HEART-TRANSPLANTATION - CYTOIMMUNOLOGICAL MONITORING ON BLOOD-CELLS AND QUANTITATIVE BIREFRINGENCE MEASUREMENTS ON ENDOMYOCARDIAL BIOPSY SPECIMENS

被引:6
|
作者
WIJNGAARD, PLJ
GIMPEL, JA
SCHUURMAN, HJ
VANDERMEULEN, A
MEYLING, FHJG
JAMBROES, G
机构
[1] HEART TRANSPLANTAT CTR,GRONINGEN,NETHERLANDS
[2] HEART TRANSPLANTAT CTR,UTRECHT,NETHERLANDS
[3] UNIV HOSP UTRECHT,DEPT INTERNAL MED,DIV IMMUNOPATHOL,DIAGNOST LAB CLIN CHEM,3584 CX UTRECHT,NETHERLANDS
[4] UNIV HOSP UTRECHT,DEPT PATHOL,3584 CX UTRECHT,NETHERLANDS
[5] UNIV HOSP UTRECHT,INST HEART LUNG,3584 CX UTRECHT,NETHERLANDS
关键词
D O I
10.1136/jcp.43.2.137
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Cytoimmunological monitoring and quantitative birefringence measurements were used as potential aids in diagnosing acute rejection after heart transplantation instead of histopathological assessment of the endomyocardial biopsy specimen alone. Cytoimmunological monitoring was based on morphological inspection and quantitation of mononuclear cells, particularly activated lymphoid cells. Quantitative birefringence measurements comprise a variable for myocyte contractile function. Its read out is the ratio of the degree of birefringence before contraction to that after. Cytoimmunological monitoring indicated significantly higher concentrations of activated lymphocytes in moderate or severe acute rejection, and quantitative birefringence measurements indicated decreased myocyte function during severe and resolved or resolving rejection. Cytoimmunological monitoring and quantitative birefringence measurements were diagnostically most useful in terms of sensitivity, specificity, and predictive value, when only data gathered before the first episode of acute rejection were considered. For cytoimmunological monitoring, diagnostic relevance was optimal when the data were expressed as relative proportions of activated lymphocytes. The quantitative birefringence measurements correlated best with analysis of the endomyocardial biopsy specimen when a cut off value of 1.25 was used. When both methods for diagnosing acute rejection were analysed together, no improvement in sensitivity (value 0.44) was found, but the specificity increased to 0.98 and the predictive value to about 0.80. It is concluded that cytoimmunological monitoring is a useful, non-invasive additional method for diagnosing the first period of acute rejection after heart transplantation and that quantitative birefringence measurements give valuable information on the extent of myocyte damage.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [31] VALUE OF ENDOMYOCARDIAL BIOPSY IN THE DIAGNOSIS OF LYMPHOMA AFTER HEART-TRANSPLANTATION - A CASE-REPORT
    LOZANO, MD
    MINDAN, FJP
    MEJUTO, FC
    FLOREZ, I
    HERREROS, J
    CLINICAL TRANSPLANTATION, 1991, 5 (01) : 33 - 35
  • [32] IS THERE A RELATION BETWEEN CYCLOPORINE TROUGH LEVELS AND ENDOMYOCARDIAL BIOPSY SCORE AFTER HEART-TRANSPLANTATION
    CANTAROVICH, M
    LATTER, D
    FITCHETT, D
    TRANSPLANTATION PROCEEDINGS, 1994, 26 (05) : 2725 - 2726
  • [33] Routine surveillance endomyocardial biopsy: Late rejection after heart transplantation - Discussion
    Curtis, JJ
    Heimansohn, DA
    Kirklin, JK
    ANNALS OF THORACIC SURGERY, 1997, 64 (05): : 1236 - 1236
  • [34] CYCLOSPORINE BLOOD MONITORING AFTER HEART-TRANSPLANTATION - A PROSPECTIVE COMPARISON OF MONOCLONAL AND POLYCLONAL RADIOIMMUNOASSAYS
    BOURGE, RC
    KIRKLIN, JK
    KETCHUM, C
    NAFTEL, DC
    MASON, DA
    SIEGEL, AL
    SCOTT, JW
    WHITEWILLIAMS, C
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1992, 11 (03): : 522 - 529
  • [35] FROZEN-SECTION EVALUATION OF ENDOMYOCARDIAL BIOPSIES FOR CLINICALLY SUSPECTED REJECTION AFTER HEART-TRANSPLANTATION
    WINTERS, GL
    HAUPTMAN, PJ
    JARCHO, JA
    SCHOEN, FJ
    LABORATORY INVESTIGATION, 1994, 70 (01) : A32 - A32
  • [36] The measurement of the bioelectrical myocardial impedance as a non-invasive method for rejection monitoring after heart-transplantation
    Pfitzmann, R
    Muller, J
    Grauhan, O
    Cohnert, T
    Hetzer, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (04): : 258 - 266
  • [37] INTRAMYOCARDIAL ELECTROGRAMS FOR THE MONITORING OF ALLOGRAFT-REJECTION AFTER HEART-TRANSPLANTATION USING SPONTANEOUS AND PACED BEATS
    AUER, T
    SCHREIER, G
    HUTTEN, H
    TSCHELIESSNIGG, KH
    ALLMAYR, T
    GRASSER, B
    IBERER, F
    WASLER, A
    PETUTSCHNIGG, B
    MULLER, H
    SCHALLDACH, M
    TRANSPLANTATION PROCEEDINGS, 1995, 27 (05) : 2621 - 2624
  • [38] Clinical relevance and outcome of routine endomyocardial biopsy to detect rejection after heart transplantation
    Kieviet, L. C.
    Szymanski, M. K.
    Van der Meer, M. G.
    Van der Kaaij, N. P.
    De Jonge, N.
    Van Laake, L. W.
    Oerlemans, M. I. F.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 224 - 225
  • [39] Clinical Relevance and Outcome of Routine Endomyocardial Biopsy to Detect Rejection after Heart Transplantation
    Kieviet, L. C.
    Szymanski, M. K.
    van der Meer, M. G.
    van der Kaaij, N. P.
    de Jonge, N.
    van Laake, L. W.
    Oerlemans, M. I.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S434 - S434
  • [40] Clinical relevance and outcome of routine endomyocardial biopsy to detect rejection after heart transplantation
    Kieviet, L.
    Szymanski, M. K.
    Van der Meer, M. G.
    Van der Kaaij, N. P.
    De Jonge, N.
    Van Laake, L. W.
    Oerlemans, M. I. F.
    EUROPEAN HEART JOURNAL, 2023, 44