Design, testing and evaluation of a fullscale post-tensioned steelfibre reinforced flat slab

被引:0
|
作者
Kanstad, Terje [1 ]
Trygstad, Steinar [2 ]
机构
[1] NTNU, Dept Struct Engn, N-7491 Trondheim, Norway
[2] THiLT Engn AS, N-6002 Alesund, Norway
来源
NORDIC CONCRETE RESEARCH | 2014年 / 50卷 / 02期
关键词
Fibres; Modelling; Structural Design; Testing;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A full-scale failure test of a post-tensioned and fibre reinforced flat-slab has been carried out. The structural system consisted of 2 by 2 spans (2 x 8,5m and 2 x 6,5m), and the slab was reinforced with tendons and 0,38 volume % steel fibres (30kg/m(3)). The load was uniform waterpressure, and strains and deflections were measured. The test is related to ongoing standardization work, and the major result is that the experimental capacities are considerably on the safe side if characteristic strength values and elastic theory for calculation of moment distribution are used. This holds both for the German design rules for fibre reinforced concrete (DIN-EN), for fib Model Code and the Norwegian guideline-proposal.
引用
收藏
页码:211 / 214
页数:4
相关论文
共 50 条
  • [21] New Methods in Efficient Post-Tensioned Slab Design Using Topology Optimization
    Sarkisian, M.
    Long, E.
    Beghini, A.
    Garai, R.
    Shook, D.
    Diaz, A.
    Henoch, R.
    STRUCTURES CONGRESS 2017: BUILDINGS AND SPECIAL STRUCTURES, 2017, : 213 - 224
  • [22] Frictionless plain bearing for post-tensioned slab on ground
    Schweighofer, Anton
    Kollegger, Johann
    BETON- UND STAHLBETONBAU, 2013, 108 (05) : 335 - 345
  • [23] Post-Tensioned Slab-Colum n Connections
    University of California, Los Angeles, United States
    不详
    不详
    Concr. Int., 2007, 4 (70-77):
  • [24] Post-tensioned slab bridge with banded transverse tendons
    Roschke, PN
    Pruski, KR
    ACI STRUCTURAL JOURNAL, 2000, 97 (01) : 3 - 10
  • [25] POST-TENSIONED REINFORCED-CONCRETE AS APPLIED TO SHIP DESIGN AND CONSTRUCTION
    ERTNER, JD
    NAVAL ENGINEERS JOURNAL, 1977, 89 (02) : 171 - 181
  • [26] Punching shear resistance of post-tensioned steel fiber reinforced concrete flat plates
    Long Nguyen-Minh
    Rovnak, Marian
    Thanh Tran-Ngoc
    Them Le-Phuoc
    ENGINEERING STRUCTURES, 2012, 45 : 324 - 337
  • [27] POST-TENSIONED REINFORCED-CONCRETE AS APPLIED TO SHIP DESIGN AND CONSTRUCTION
    EVANS, JH
    GERWICK, BC
    NAVAL ENGINEERS JOURNAL, 1977, 89 (03) : 76 - 78
  • [28] ULTIMATE STRENGTH TESTS OF POST-TENSIONED FLAT PLATES
    GERBER, LL
    BURNS, NH
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1971, 16 (06): : 40 - &
  • [29] THE PUNCHING BEHAVIOR OF UNBONDED POST-TENSIONED FLAT PLATES
    FRANKLIN, SO
    LONG, AE
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1982, 73 (SEP): : 609 - 631
  • [30] POST-TENSIONED FLAT PLATE TO COLUMN CONNECTION BEHAVIOR
    SMITH, SW
    BURNS, NH
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1974, 19 (03): : 74 - 91