INTERLABORATORY COMPARISON OF ACTINIDES IN HUMAN TISSUE PU-239 AND PU-240

被引:5
|
作者
INN, KGW
LIGGETT, WS
VOLCHOK, HL
FEINER, MS
MCINROY, JF
POPPLEWELL, DS
PERCIVAL, DR
WESSMAN, RA
BOWEN, VT
LIVINGSTON, HD
KATHREN, RL
KAWAMURA, H
机构
[1] ENVIRONM MEASUREMENTS LAB,NEW YORK,NY
[2] UNIV CALIF LOS ALAMOS SCI LAB,LOS ALAMOS,NM 87544
[3] NATL RADIOL PROTECT BOARD,DIDCOT OX11 0RQ,OXON,ENGLAND
[4] RADIOL & ENVIRONM SCI LAB,IDAHO FALLS,ID
[5] TMA,NORCAL,RICHMOND,CA
[6] WOODS HOLE OCEANOG INST,WOODS HOLE,MA 02543
[7] US TRANSURANIUM REGISTRY,RICHLAND,WA
[8] NATL INST RADIOL SCI,NAKAMINATO,IBARAKI 31112,JAPAN
关键词
D O I
10.1007/BF02039847
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An international laboratory intercomparison of actinides in human tissues was organized by the United States Transuranium Registry and the National Institute of Standards and Technology. Five laboratories from the United States, United Kingdom, and Japan participated in the intercomparison. The laboratories were requested to analyze Standard Reference Materials 4351 (Human Lung) and 4352 (Human Liver) for239Pu and240Pu concentration. Approximately equivalent measurement capabilities were generally found among the participants. The results of this intercomparison were statistically comparable to those used for the original certification of the SRM's and were combined for a re-evaluation of the certified values. The combined data sets provide a better characterization of the inhomogeneity of these reference materials and result in a better basis for certification. © 1990 Akadémiai Kiadó.
引用
收藏
页码:219 / 229
页数:11
相关论文
共 50 条
  • [41] FALLOUT DOSE ESTIMATES BASED UPON MEASUREMENTS OF PU-239, PU-240 IN AUTOPSY SAMPLES
    SINGH, NP
    LEWIS, LL
    WRENN, ME
    HEALTH PHYSICS, 1987, 52 : S77 - S77
  • [42] CONCENTRATIONS OF PU-239, PU-240, SR-90 AND CS-137 IN THE ENVIRONMENT
    YAMATO, A
    NARITA, O
    AKUTSU, K
    MIYAGAWA, N
    GOTA, T
    HIRAYAMA, A
    HEALTH PHYSICS, 1979, 36 (04): : 560 - 560
  • [43] PRECISE HALF-LIFE MEASUREMENTS OF PU-238, PU-239, PU-240 AND CM-242
    JAFFEY, AH
    DIAMOND, H
    BENTLEY, WC
    FLYNN, KF
    ROKOP, DJ
    ESSLING, AM
    WILLIAMS, J
    GRACZYK, DG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 174 (SEP): : 96 - 96
  • [44] Optimization of counting conditions and simultaneous determination of Pu-238, Pu-239 and Pu-240 by liquid scintillation counting
    Toribio, M
    Garcia, JF
    IzquierdoRidorsa, A
    Rauret, G
    LIQUID SCINTILLATION SPECTROMETRY 1994, 1996, : 157 - 165
  • [45] THE MEASUREMENT OF PB-210 AND PU-239,PU-240 IN THE LUNGS OF SMOKERS AND NON-SMOKERS
    COHEN, BS
    HARLEY, NH
    FISENNE, IM
    HEALTH PHYSICS, 1980, 39 (06): : 1045 - 1046
  • [46] A COMPARISON OF THE DISTRIBUTION OF INDUSTRIALLY RELEASED PU-238 AND FALLOUT PU-239,PU-240 IN TEMPERATE, NORTHERN UNITED-STATES SOILS
    ALBERTS, JJ
    BOBULA, CM
    FARRAR, DT
    JOURNAL OF ENVIRONMENTAL QUALITY, 1980, 9 (04) : 592 - 596
  • [47] NEUTRON FISSION CROSS-SECTIONS OF PU-239 AND PU-240 RELATIVE TO U-235
    WESTON, LW
    TODD, JH
    NUCLEAR SCIENCE AND ENGINEERING, 1983, 84 (03) : 248 - 259
  • [48] SIMULTANEOUS DETERMINATION OF PU-241,PU-238 AND PU-239,PU-240 IN LOW ACTIVITY ENVIRONMENTAL-SAMPLES
    HAKANEN, M
    JAAKKOLA, T
    KORPELA, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (2-3): : 382 - 385
  • [49] DETERMINATION OF THE PU-239 PU-240 ISOTOPIC RATIO BY HIGH-RESOLUTION ALPHA-SPECTROMETRY
    AMOUDRY, F
    BURGER, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 223 (2-3): : 360 - 367
  • [50] LABORATORY STUDIES OF THE DIAGENESIS AND MOBILITY OF PU-239,PU-240 AND CS-137 IN NEARSHORE SEDIMENTS
    SHOLKOVITZ, ER
    COCHRAN, JK
    CAREY, AE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1983, 47 (08) : 1369 - 1379