COMPARISON OF THE EVAPORATIVE LIGHT-SCATTERING DETECTOR (ELSD) AND REFRACTIVE-INDEX DETECTOR (RID) IN LIPID ANALYSIS

被引:63
|
作者
HOPIA, AI
OLLILAINEN, VM
机构
[1] University of Helsinki, Department of Applied Chemistry and Microbiology, Food Chemistry Division, SF-00710, Helsinki
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 12期
关键词
D O I
10.1080/10826079308019586
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The properties of an evaporative light scattering detector (ELSD) and a refractive index detector (RID) in isocratic HPLC analysis of lipids are compared. The effect of molecular structure, especially the unsaturation level, on the detector response is studied using eight different lipid standards. Linearity and sensitivity are compared. Quantitation of an unknown sample is also performed. The sensitivity of the ELSD was slightly better than that of the RID, the detector limits of triolein being 30 ng/injection and 50 ng/injection, respectively. The linearity of the ELSD was considered only approximate compared with that of the RID the response factors of the calibration curves being 0.9554 and 0.9999, respectively. The effect of the molecular structure on the detector response was higher with the RID than with the ELSD. The relative standard deviation (SD%) of responses was 23% for the RID and 12% for the ELSD. The unsaturation level had a greater effect on the detector response of the RID than on that of the ELSD. This study indicates that a standard deviation (SD) of at least 13% is to be expected with the ELSD and an even higher SD with the RI detector when quantitating heterogeneous mixtures or unknown compounds.
引用
收藏
页码:2469 / 2482
页数:14
相关论文
共 50 条
  • [21] Comparison of refractive index detection (RID) to evaporate ligh scattering detection (ELSD) for analysis of sugars in presweetened cereals
    Steinike, SM
    LC GC NORTH AMERICA, 2003, : 39 - 39
  • [22] REFRACTIVE-INDEX DETECTOR USING ZEEMAN INTERFEROMETRY
    JOHNSTON, RG
    GRACE, WK
    APPLIED OPTICS, 1990, 29 (31): : 4720 - 4724
  • [23] Enantioseparation and Thermodynamic Properties of Aleuritic Acid by High Performance Liquid Chromatography with Evaporative Light-Scattering Detector (HPLC-ELSD)
    Li, Kun
    Zhang, Wenwen
    Liu, Lanxiang
    Zheng, Hua
    Li, Kai
    Xu, Juan
    Zhang, Hong
    Shipin Kexue/Food Science, 2019, 40 (02): : 200 - 207
  • [24] LIGHT-SCATTERING FROM OPTICAL FIBERS WITH ARBITRARY REFRACTIVE-INDEX DISTRIBUTIONS
    MARCUSE, D
    PRESBY, HM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1975, 65 (04) : 367 - 375
  • [25] STATIC MEASUREMENTS OF REFRACTIVE-INDEX INCREMENTS AT 633 NM WITH A MODIFIED REFRACTIVE-INDEX DETECTOR
    SORIA, V
    LLOPIS, A
    CELDA, B
    CAMPOS, A
    FIGUERUELO, JE
    POLYMER BULLETIN, 1985, 13 (01) : 83 - 88
  • [26] MEASUREMENT OF THE REFRACTIVE-INDEX OF ATOMIZED LIQUID-DROPS BY LIGHT-SCATTERING
    CARD, JBA
    JONES, AR
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 1991, 8 (04) : 267 - 273
  • [27] USE OF AN EVAPORATIVE LIGHT-SCATTERING MASS DETECTOR IN SEDIMENTATION FIELD FLOW FRACTIONATION
    OPPENHEIMER, LE
    MOUREY, TH
    JOURNAL OF CHROMATOGRAPHY, 1984, 298 (02): : 217 - 224
  • [28] EFFECT OF THE WAVELENGTH OF THE LASER-BEAM ON THE RESPONSE OF AN EVAPORATIVE LIGHT-SCATTERING DETECTOR
    RIGHEZZA, M
    GUIOCHON, G
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (13): : 2709 - 2729
  • [29] An investigation into detector limitations using evaporative light-scattering detectors for pharmaceutical applications
    Webster, GK
    Jensen, JS
    Diaz, AR
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (09) : 484 - 490
  • [30] The evaporative light scattering detector: some applications in pharmaceutical analysis
    Kohler, M
    Haerdi, W
    Christen, P
    Veuthey, JL
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (08) : 475 - 484