Reproducibility assessment of an instrument for measuring the axial force of the tongue

被引:4
|
作者
de Araujo, Taynara Gomes [1 ,2 ]
Rodrigues, Thalyla Magalhaes [1 ,2 ]
Moreira Moraes Furlan, Renata Maria [1 ,2 ]
de Las Casas, Estevam Barbosa [1 ,2 ]
Motta, Andrea Rodrigues [1 ,2 ]
机构
[1] Univ Fed Minas Gerais, Dept Fonoaudiol, Belo Horizonte, MG, Brazil
[2] Univ Fed Minas Gerais, Belo Horizonte, MG, Brazil
来源
CODAS | 2018年 / 30卷 / 03期
关键词
Tongue; Muscle Strength; Evaluation; Equipment and Supplies; Speech; Language and Hearing; Sciences;
D O I
10.1590/2317-1782/20182017191
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Evaluate the reproducibility of Folding, a portable instrument for measuring axial tongue force. Methods: Axial force or the tongue was measured in 49 individuals (30 women and 19 men) aged 18-25 years using the Forting portable instrument. Measurements were performed in three days at intervals of 7 +/- 2 days. On each day, three 7-second measurements were performed with one-minute intervals between them. The coefficient of variation, Wilcoxon paired test, and intraclass correlation coefficient were used in the statistical analysis of the data. Maximum and mean tongue force values were analyzed, and comparison between them was performed using three approaches: the mean of the three values; the mean of the two highest values; the highest value of each measurement. Results: In the analysis of mean tongue force, the coefficient of variation was considered desirable and the intraclass correlation coefficient was acceptable. Significant differences were observed regarding the maximum value between the second and third days. mean of the two highest values and mean of the three values between the first and second days and the second and third days. In the analysis of maximum tongue force, the coefficient or variation and the intraclass correlation coefficient were acceptable. Significant difference was found only in the comparison between the second and third days. Conclusion: Good reproducibility orate data obtained with the use of the Forling portable instrument was observed.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Measuring instrument on line of steel-dragline, force based on active vibration
    Yao, SF
    Zhao, JB
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2466 - 2467
  • [32] Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength
    Douma K.W.
    Regterschot G.R.H.
    Krijnen W.P.
    Slager G.E.C.
    Van Der Schans C.P.
    Zijlstra W.
    BMC Sports Science, Medicine and Rehabilitation, 8 (1)
  • [33] A method to estimate the axial force applied to a surgical instrument tip considering the effect of the gravity
    Kim, Suyong
    Kim, Cheongjun
    Lee, Doo Yong
    2017 11TH ASIAN CONTROL CONFERENCE (ASCC), 2017, : 1246 - 1251
  • [34] System for measuring finger force profiles for dexterity assessment
    Badza, Milica M.
    Novicic, Marija M.
    Duric-Jovicic, Milica
    Jankovic, Milica M.
    Popovic, Mirjana B.
    2018 26TH TELECOMMUNICATIONS FORUM (TELFOR), 2018, : 771 - 774
  • [35] AXIAL FORCE ESTIMATION OF ELASTICALLY CLAMPED BEAM BY MEASURING NATURAL FREQUENCIES.
    Sato, Hidenori
    Taniguti, Tadasi
    Iwata, Yosio
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 1987, 53 (492): : 1629 - 1635
  • [36] Improvement of accuracy of method for measuring axial force of rail based on natural frequency
    Urakawa F.
    Abe K.
    Takahashi H.
    2016, Ken-yusha Inc. (57) : 125 - 132
  • [37] Indirect approach of measuring the axial force on turbo-jet engine rotor
    Kolarevic, Nenad
    Crnojevic, Stevan
    Stankovic, Milos
    Milos, Marko
    MATERIALS TODAY-PROCEEDINGS, 2019, 12 : 335 - 339
  • [38] A STUDY ON TOOTH MARKS - ON THE REPRODUCIBILITY AND IDENTIFICATION OF TOOTH MARKS BY MEANS OF A 3-DIMENSIONAL MEASURING INSTRUMENT
    FURUKAWA, A
    TAKEI, T
    JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1984, 24 (04): : 381 - 381
  • [39] FUNCTIONAL ASSESSMENT OF THE HAND - REPRODUCIBILITY, ACCEPTABILITY, AND UTILITY OF A NEW SYSTEM FOR MEASURING STRENGTH
    HELLIWELL, P
    HOWE, A
    WRIGHT, V
    ANNALS OF THE RHEUMATIC DISEASES, 1987, 46 (03) : 203 - 208
  • [40] REPRODUCIBILITY TESTING OF THE HP CE INSTRUMENT
    JEGLE, U
    HEWLETT-PACKARD JOURNAL, 1995, 46 (03): : 50 - 56