EFFECT OF A VOLUMATIC SPACER AND MOUTH RINSING ON SYSTEMIC ABSORPTION OF INHALED CORTICOSTEROIDS FROM A METERED DOSE INHALER AND DRY POWDER INHALER

被引:109
|
作者
SELROOS, O [1 ]
HALME, M [1 ]
机构
[1] MJOLBOLSTA HOSP,SF-10350 MJOLBOLSTA,FINLAND
关键词
D O I
10.1136/thx.46.12.891
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. Methods Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without mouth rinsing and beclomethasone dipropionate given by metered dose inhaler with or without a spacing device (Volumatic) on serum cortisol concentrations and urinary cortisol excretion in patients with asthma taking an inhaled corticosteroid. Each treatment period was two weeks with a two week washout period. Serum cortisol concentrations at 0800 hours on day 14 and the 24 hour urinary excretion of cortisol were measured. In study 1 24 patients taking beclomethasone dipropionate 500-mu-g twice a day inhaled with (n = 10) or without (n = 14) a Volumatic spacing device were switched to a budesonide dry powder inhaler, 600-mu-g to be taken twice a day without mouth rinsing. In study 2 10 patients took budesonide 800-mu-g twice a day with and without mouth rinsing and without swallowing the rinsing water. In study 3 17 patients took budesonide 800-mu-g twice daily with mouth rinsing and beclomethasone dipropionate 500-mu-g twice daily with the spacing device and mouth rinsing. Results In study 1 no difference was seen between budesonide without mouth rinsing and beclomethasone dipropionate without a spacer: beclomethasone with spacer caused less suppression of cortisol (mean (SD) serum cortisol concentration: beclomethasone and spacer 487(148), budesonide 368(145) nmol/l). In study 2 mouth rinsing caused less suppression of morning serum cortisol concentrations (rinsing 440(63), no rinsing 375(56) nmol/1). In study 3 there was no difference in serum or urinary cortisol concentrations between twice daily beclomethasone dipropionate 500-mu-g inhaled by Volumatic spacer or budesonide by Turbuhaler 800-mu-g twice daily, both with mouth rinsing. Individual serum cortisol values were within the normal range in all patients except one in study 1. Conclusion Systemic absorption of a corticosteroid inhaled from a metered dose inhaler is reduced by using a spacing device and that from a dry powder inhaler by mouth rinsing.
引用
收藏
页码:891 / 894
页数:4
相关论文
共 50 条
  • [1] Comparison of the lung absorption of FK224 inhaled from a pressurized metered dose inhaler and a dry powder inhaler by healthy volunteers
    Nakate, T
    Yoshida, H
    Ohike, A
    Tokunaga, Y
    Ibuki, R
    Kawashima, Y
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2003, 56 (03) : 319 - 325
  • [2] Pharmacokinetics of Salbutamol Delivered from the Unit Dose Dry Powder Inhaler: Comparison with the Metered Dose Inhaler and Diskus Dry Powder Inhaler
    Moore, Alison
    Riddell, Kylie
    Joshi, Shashidhar
    Chan, Robert
    Mehta, Rashmi
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 164 - +
  • [3] The bronchoprotective efficacy of salbutamol inhaled from a new metered-dose powder inhaler compared with a conventional pressurized metered-dose inhaler connected to a spacer
    Seppala, OP
    Herrala, J
    Hedman, J
    Alanko, K
    Liipo, K
    Terho, E
    Pietinalho, A
    Nyholm, JE
    Nieminen, MM
    RESPIRATORY MEDICINE, 1998, 92 (03) : 578 - 583
  • [4] COMPARISON OF INHALED TERBUTALINE ADMINISTERED BY EITHER THE TURBUHALER DRY POWDER INHALER OR A METERED-DOSE INHALER WITH SPACER IN PRESCHOOL-CHILDREN WITH ASTHMA
    LABERGE, S
    SPIER, S
    DRBLIK, SP
    TURGEON, JP
    JOURNAL OF PEDIATRICS, 1994, 124 (05): : 815 - 817
  • [5] Comparison of Easyhaler® Metered-Dose, Dry Powder Inhaler and a Pressurised Metered-Dose Inhaler plus Spacer in the Treatment of Asthma in Children
    K. Juntunen-Backman
    M. Kajosaari
    K. Laurikainen
    A. Malinen
    M. Kaila
    L. Mustala
    U. Kaski
    O. Linna
    M. Marenk
    P. Toivanen
    Clinical Drug Investigation, 2002, 22 : 827 - 835
  • [6] Comparison of Easyhaler® metered-dose, dry powder inhaler and a pressurised metered-dose inhaler plus spacer in the treatment of asthma in children
    Juntunen-Backman, K
    Kajosaari, M
    Laurikainen, K
    Malinen, A
    Kaila, M
    Mustala, L
    Kaski, U
    Linna, O
    Marenk, M
    Toivanen, P
    CLINICAL DRUG INVESTIGATION, 2002, 22 (12) : 827 - 835
  • [7] Clinical equivalence of budesonide dry powder inhaler and pressurized metered dose inhaler
    Srichana, Teerapol
    Juthong, Siwasak
    Thawithong, Ekawat
    Supaiboonpipat, Supot
    Soorapan, Suchada
    CLINICAL RESPIRATORY JOURNAL, 2016, 10 (01): : 74 - 82
  • [8] Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler
    Kemp, JP
    Hill, MR
    Vaughan, LM
    Meltzer, EO
    Welch, MJ
    Ostrom, NK
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1997, 79 (04) : 322 - 326
  • [9] Effect of flow rate on coarse particle mass (CPM) from a dry powder inhaler (DPI) and a metered dose inhaler (MDI) / spacer delivering salbutamol
    Suggett, Jason
    Costa, Rob
    Nagel, Mark
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [10] Study of ageing of dry powder inhaler and metered dose inhaler by atomic force microscopy
    Harder, Christophe
    Lesniewska, Eric
    Laroche, Christophe
    POWDER TECHNOLOGY, 2011, 208 (02) : 252 - 259