Due to heavy proliferation of power electronic and non-linear loads on a present day utility system, the DC current accumulated at the distribution transformer is significant. DC current shifts the operating point of the magnetization characteristic and hence causes the magnetizing current to exhibit severe asymmetry between positive and negative half cycles in magnitude and shape, owing to magnetic saturation. It affects the shape of input current and recreates a DC current at the input with magnitude even greater. This paper describes the work on influence of DC current on input current in a loaded transformer, and a system to divert DC current completely away from the transformer. Implementation was done with a specially designed current sensor and a fast responsive controlled current source. The later was implemented in power electronic with dosed loop control. The work was challenging because measuring of small DC current superimposed with a large AC current was not straightforward, and also injecting a small DC current accurately against a large AC voltage was not straightforward. Both these challenges were successfully overcome and an extremely good DC current diversion system was developed. Details of the design and results of investigations are presented.
引用
收藏
页码:15 / 26
页数:12
相关论文
共 50 条
  • [21] Broadband Transfer Characteristics of DC Electronic Current Transformers
    Yang, Songyu
    Le, Jian
    Wang, Jing
    Wang, Weihao
    IEEE ACCESS, 2024, 12 : 130334 - 130346
  • [22] Elimination of inrush current in parallel transformers by sequential phase energization
    Basu, K. P.
    Asghar, Ali
    Morris, Stella
    IEICE ELECTRONICS EXPRESS, 2007, 4 (05): : 147 - 152
  • [23] Determination of Capitalization Values for No Load Loss and Load Loss in Distribution Transformers
    Wijayapala, W. D. A. S.
    Gamage, S. R. K.
    Bandara, H. M. S. L. G.
    ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA, 2016, 49 (03): : 11 - 20
  • [24] Detection Method of the DC Bias in Distribution Power Transformers
    Buticchi, Giampaolo
    Lorenzani, Emilio
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (08) : 3539 - 3549
  • [25] TRANSIENT OPERATING CONDITIONS OF CURRENT TRANSFORMERS WITH RL LOAD
    ILINICHN.VV
    ELECTRICAL TECHNOLOGY, 1970, 3 : 46 - &
  • [26] DISTRIBUTION AND ELIMINATION OF INTRAVENOUSLY INJECTED URINARY TRYPSIN-INHIBITOR
    JONSSONBERLING, BM
    OHLSSON, K
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (06): : 549 - 557
  • [27] A thermal loading guide for residential distribution transformers based on time-variant current load models
    Heunis, SW
    Herman, R
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (03) : 1294 - 1298
  • [28] Nonsinusoidal Load Current Effect on the Electrical and Thermal Operating Parameters of Oil Filled Power Distribution Transformers
    Cazacu, Emil
    Petrescu, Maria-Catalina
    Ionita, Valentin
    Petrescu, Lucian
    2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,
  • [29] The study on DC bias distribution considering AC-DC hybrid transformers
    Song, Y. D.
    Ge, W. C.
    He, W. T.
    ADVANCES IN ENGINEERING MATERIALS AND APPLIED MECHANICS, 2016, : 721 - 725
  • [30] EFFECTS OF COLD LOAD PICKUP ON DISTRIBUTION TRANSFORMERS.
    Wilde, R.L.
    Engineering News-Record, 1981,