RADIOLUCENCY AT THE BONE-CEMENT INTERFACE IN TOTAL KNEE REPLACEMENT - THE EFFECTS OF BONE-SURFACE PREPARATION AND CEMENT TECHNIQUE

被引:100
|
作者
RITTER, MA
HERBST, SA
KEATING, EM
FARIS, PM
机构
[1] Center for Hip and Knee Surgery, Mooresville, IN 46158
来源
关键词
D O I
10.2106/00004623-199401000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three hundred and sixty-three knees (221 patients) that had been treated with total arthroplasty between 1975 and 1985 were divided into three groups on the basis of the preparation of the surface of the bone and the technique of the cement application. Group 1 (155 knees) was treated with irrigation of the bone surfaces with a syringe and manual packing of the bone cement. Group 2 (sixty-one knees) had high-volume, high-pressure lavage of the bone surfaces and manual packing of the cement. Group 3 (147 knees) had high-volume, high-pressure lavage and pressure injection of low-viscosity methylmethacrylate cement. Radiolucency was evaluated at each followup interval, and the findings were subjected to chi-square analysis and Kaplan-Meier survival analysis. Chi-square analysis of the data at one and three years indicated a significantly higher frequency of lines at the bone-cement interface in the femur and tibia in Group-1 knees compared with those in Groups 2 and 3. The survival curves showed increasing rates of radiolucency adjacent to the tibial components of the knees that had been prepared with lavage that was not high-volume and high-pressure and that had been prepared with finger-packing of cement (Group 1). This may partially explain the clinical problem of loosening of tibial components despite acceptable alignment. This study demonstrates that proper preparation of the cancellous bone and pressurization of the cement reduce the initial occurrence of a radiolucent line, which may have a positive effect on the ultimate failure of at least the tibial component.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 50 条
  • [22] Experimental investigation of the effect of bone surface macro-groove preparation on the strength of bone-cement interface
    Kumar, Ajay
    Shitole, Pankaj
    Kumar, Rajeev
    Ghosh, Rajesh
    MATERIALS TODAY COMMUNICATIONS, 2021, 28
  • [23] Histology of the bone-cement interface in retrieved Oxford unicompartmental knee replacements
    Kendrick, B. J. L.
    James, A. R.
    Pandit, H.
    Gill, H. S.
    Price, A. J.
    Blunn, G. W.
    Murray, D. W.
    KNEE, 2012, 19 (06): : 918 - 922
  • [24] Effect of cement modulus on the shear properties of the bone-cement interface
    Orthopaedic BioMaterials Laboratory, S-2035 Davis Center, 480 West Ninth Avenue, Columbus, OH 43210-1128, United States
    Biomaterials, 17 (1561-1567):
  • [25] Effect of cement modulus on the shear properties of the bone-cement interface
    Funk, MJ
    Litsky, AS
    BIOMATERIALS, 1998, 19 (17) : 1561 - 1567
  • [26] CHANGES IN THE BONE-CEMENT INTERFACE AFTER TOTAL HIP-REPLACEMENT - AN INVIVO ANIMAL STUDY
    RADIN, EL
    RUBIN, CT
    THRASHER, EL
    LANYON, LE
    CRUGNOLA, AM
    SCHILLER, AS
    PAUL, IL
    ROSE, RM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (08): : 1188 - 1200
  • [27] The effect of different cement insertion techniques on the bone-cement interface
    Horne, JG
    Bruce, W
    Devane, PA
    Teoh, HH
    JOURNAL OF ARTHROPLASTY, 2002, 17 (05): : 579 - 583
  • [28] INITIAL EXPERIENCES WITH A TOTAL KNEE PROSTHESIS IMPLANTED WITHOUT BONE-CEMENT
    RITTER, H
    DEGE, U
    KUBBA, R
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (1-2) : 89 - 93
  • [29] SURFACE-STRUCTURES OF BONE-CEMENT
    WILLERT, HG
    BUCHHORN, G
    ZICHNER, L
    MULLER, K
    SEMLITSCH, M
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1979, 117 (04): : 674 - 683
  • [30] REPLACEMENT OF HERNIATED CERVICAL DISKS BY BONE-CEMENT
    ROOSEN, K
    FORTSCHRITTE DER MEDIZIN, 1982, 100 (45) : 2120 - &