AN AUTOMATIC 4-CIRCLE DIFFRACTOMETER DESIGNED FOR PRECISE LATTICE-PARAMETER DETERMINATION

被引:10
|
作者
KUCHARCZYK, D
PIETRASZKO, A
LUKASZEWICZ, K
机构
[1] Polish Acad of Sciences, Wroclaw
关键词
D O I
10.1107/S0021889892013086
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The method introduced by Bond (1960) appears to be the most convenient for high-precision lattice-parameter determination in a broad temperature range for a large number of single-crystalline materials. The Bond diffractometers built up to now require very accurate and time-consuming setting of specimens. The setting must be checked and corrected after each temperature change, which makes the experiment rather tedious. The authors have reconstructed the KUMA KM4 automatic four-circle diffractometer to fit the requirements of the Bond method. The collimator with exchangeable slits is much longer (240mm), which improves the collimation and allows measurement of the intensities of X-ray reflections with 20<168 at both sides of the primary beam. The measurements are automatic and can be performed with or without a graphite monochromator.
引用
收藏
页码:467 / 467
页数:1
相关论文
共 50 条
  • [31] NEW SINGLE-CRYSTAL HEATER FOR PRECESSION CAMERA AND 4-CIRCLE DIFFRACTOMETER
    BROWN, GE
    SUENO, S
    PREWITT, CT
    AMERICAN MINERALOGIST, 1973, 58 (7-8) : 698 - 704
  • [32] MOUNTING A CLOSED CYCLE 2 STAGE COOLING DEVICE ON A 4-CIRCLE DIFFRACTOMETER
    LARSEN, FK
    HENRIKSEN, K
    RASMUSSEN, SE
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C415 - C415
  • [33] DOING DOUBLE-CRYSTAL DIFFRACTION EXPERIMENTS WITH A CONVENTIONAL 4-CIRCLE DIFFRACTOMETER
    CHAO, WK
    GAO, EZ
    WONG, HK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (09): : 2558 - 2560
  • [34] ORIENTATION MATRIX REFINEMENT DURING 4-CIRCLE DIFFRACTOMETER DATA-COLLECTION
    CLEGG, W
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 (NOV): : 703 - 704
  • [35] NEW ABSOLUTE METHOD FOR LATTICE-PARAMETER DETERMINATION
    VAVRDA, J
    KOVOVE MATERIALY-METALLIC MATERIALS, 1979, 17 (05): : 620 - 624
  • [36] DETERMINATION OF LATTICE-PARAMETER FOR GDCO2
    CREAGH, DC
    AYLING, SH
    JOURNAL OF MATERIALS SCIENCE, 1978, 13 (12) : 2723 - 2725
  • [37] UPGRADE OF TRIPLE-AXIS 4-CIRCLE DIFFRACTOMETER AT PF-BL3A
    TAKAGI, Y
    KIKUCHI, T
    MIZUTANI, T
    IMAFUKU, M
    SASAKI, S
    MORI, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1802 - 1805
  • [38] VARIABLE-TEMPERATURE ACCESSORY FOR USE WITH A 4-CIRCLE X-RAY DIFFRACTOMETER
    STROUSE, CE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (07): : 871 - 876
  • [39] NEW MEASURING PROCEDURE FOR THE USE OF A GASKETED DIAMOND ANVIL CELL ON A 4-CIRCLE DIFFRACTOMETER
    SCHULZ, H
    DENNER, W
    DAMOUR, H
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S345 - S345
  • [40] A METHOD OF ALIGNMENT OF A 4-CIRCLE DIFFRACTOMETER USING A SMALL COLLIMATOR IN THE CENTER OF THE EULERIAN CRADLE
    GEREMIA, S
    BURZLAFF, H
    ROTHAMMEL, W
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1994, 27 : 1061 - 1063