AUTOMATIC LEFT-VENTRICULAR VOLUME MEASUREMENTS ON CONTRAST-ENHANCED ULTRAFAST CINE MAGNETIC-RESONANCE-IMAGING

被引:3
|
作者
MATSUMURA, K
NAKASE, E
HAIYAMA, T
UTSUNOMIYA, S
机构
[1] Department of Internal Medicine, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaninakano-cho, Nishishichijyo
[2] Department of Radiology, Kyoto Minami Hospital, Shimogyo-ku, Kyoto, 600, 8 Minaminakano-cho, Nishishichijyo
[3] Central Research Institute, Shimadzu Corporation, Nakagyo-ku, Kyoto, 604
关键词
MAGNETIC RESONANCE (MR) IMAGING; HEART; MAGNETIC RESONANCE (MR); TECHNIQUE; MRI;
D O I
10.1016/0720-048X(95)00641-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the accuracy of automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine magnetic resonance (MR) images, we compared the values obtained by this method with those obtained using intravenous digital subtraction left ventriculography. High-quality single breath-hold contrast-enhanced ultrafast cine MR images were obtained in all cardiac phases on horizontal and vertical long axis sections of the left ventricle. For ultrafast cine MR imaging, a phase-rewind gradient-echo (rewind-SMASH) sequence was used. Automatic extraction of the left ventricular inner contour on contrast-enhanced ultrafast cine MR images was performed in all cardiac phases. High-quality left ventricular images of the horizontal long axis section were obtained in 127 of 160 patients (79%). The automatic extraction of the left ventricular contour was easily performed on high-quality images with very short processing time (4 s/frame). The values for left ventricular volumes obtained with the automatic extraction method on contrast-enhanced ultrafast cine MR imaging were correlated well with those obtained with the manual extraction method and IV-DSA in high quality cardiac images. The biplane modified Simpson's method using automatic extraction is an accurate and highly reproducible method for evaluating left ventricular volumes.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 50 条
  • [41] Semiautomatic detection of left ventricular contours in contrast-enhanced echocardiographic images: Comparison with magnetic resonance imaging
    Morales, MA
    Positano, V
    Lombardi, M
    Rodriguez, O
    Passera, M
    Rovai, D
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (08) : 876 - 882
  • [42] INTERSTUDY REPRODUCIBILITY OF BIPLANE CINE NUCLEAR-MAGNETIC-RESONANCE MEASUREMENTS OF LEFT-VENTRICULAR FUNCTION
    BENJELLOUN, H
    CRANNEY, GB
    KIRK, KA
    BLACKWELL, GG
    LOTAN, CS
    POHOST, GM
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (16): : 1413 - 1420
  • [43] Left-ventricular reduction surgery: Pre- and postoperative evaluation by cine magnetic resonance imaging
    Kivelitz, DE
    Hotz, H
    Borges, AC
    Enzweiler, CNH
    Wiese, TH
    Lembcke, A
    Konertz, W
    Baumann, G
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 336 - 340
  • [44] QUANTITATIVE-ANALYSIS OF REGIONAL LEFT-VENTRICULAR FUNCTION AFTER MYOCARDIAL-INFARCTION IN THE PIG ASSESSED WITH CINE MAGNETIC-RESONANCE-IMAGING
    HOLMAN, ER
    VLIEGEN, HW
    VANDERGEEST, RJ
    REIBER, JHC
    VANDIJKMAN, PRM
    VANDERLAARSE, A
    DEROOS, A
    VANDERWALL, EE
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) : 161 - 169
  • [45] Contrast-enhanced magnetic resonance imaging of the breast
    Helbich, TH
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (03) : 208 - 219
  • [46] Contrast-Enhanced Cardiac Magnetic Resonance Imaging
    Restrepo, Carlos S.
    Tavakoli, Sina
    Marmol-Velez, Alejandro
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 739 - +
  • [47] LEFT-VENTRICULAR DIMENSIONS AND MASS USING MAGNETIC-RESONANCE-IMAGING IN FEMALE ENDURANCE ATHLETES
    RILEYHAGAN, M
    PESHOCK, RM
    STRAYGUNDERSEN, J
    KATZ, J
    RYSCHON, TW
    MITCHELL, JH
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (12): : 1067 - 1074
  • [48] QUANTITATION OF GLOBAL AND REGIONAL LEFT-VENTRICULAR FUNCTION BY CINE MAGNETIC-RESONANCE-IMAGING DURING DOBUTAMINE STRESS IN NORMAL HUMAN-SUBJECTS
    VANRUGGE, FP
    HOLMAN, ER
    VANDERWALL, EE
    DEROOS, A
    VANDERLAARSE, A
    BRUSCHKE, AVG
    EUROPEAN HEART JOURNAL, 1993, 14 (04) : 456 - 463
  • [49] MAGNETIC-RESONANCE-IMAGING OF LEFT-VENTRICULAR MASS, GEOMETRY AND FUNCTION IN ELITE CYCLISTS AND WEIGHTLIFTERS
    VANDERWALL, EE
    PLUIM, BM
    DEROOS, A
    SIEBELINK, HMJ
    CHIN, JC
    VANDERLAARSE, A
    BRUSCHKE, AVG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A89 - A89
  • [50] DIFFERENTIATION OF HYPERTROPHIC CARDIOMYOPATHY FROM HYPERTENSIVE LEFT-VENTRICULAR HYPERTROPHY BY MAGNETIC-RESONANCE-IMAGING
    DOYOSHITA, H
    MURAKAMI, E
    TAKEKOSHI, N
    MATSUI, S
    NAKATOH, H
    ENYAMA, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (08): : 972 - 973