CORRECTION FACTORS FOR FRICKE DOSIMETRY IN HIGH-ENERGY ELECTRON-BEAMS

被引:6
|
作者
MA, CM
NAHUM, AE
机构
[1] Inst. of Cancer Res., R. Marsden Hospital, Sutton
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1993年 / 38卷 / 03期
关键词
D O I
10.1088/0031-9155/38/3/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents Fricke-to-water dose conversion and wall correction factors for Fricke ferrous sulphate dosimetry in high-energy electron beams. The dose conversion factor has been calculated as the ratio of the mean dose in water to the mean dose in the Fricke solution with a water-walled vessel and the wall correction factor accounts for the change in the Fricke dose due to the presence of the non-water wall material. The EGS4 (Electron Gamma Shower version 4) Monte Carlo code system has been employed in this work together with the application of a correlated sampling variance reduction technique. The results show that for a Fricke dosimeter of 1.354 cm diameter and 5.5 cm length the dose conversion factor is nearly constant at 1.004 (within 0.1%) for electron energies of 11-25 MeV if the dosimeter is placed at the depth of maximum dose but can vary by a few per cent if the dosimeter is placed on the descending portion of the depth-dose curve. The wall corrections are smaller than 0.3% for 0.1 cm thick polystyrene vessels. For 0.1 cm thick Pyrex glass vessels the wall correction factor varies from 0.989 for 11 MeV at 2.75 cm depth to 0.997 for 25 MeV at 7 cm depth. This confirms recent experimental findings that Fricke doses obtained with glass-walled vessels were up to 1% higher than those with polystyrene-walled vessels.
引用
收藏
页码:423 / 438
页数:16
相关论文
共 50 条
  • [21] METHOD OF OBTAINING HIGH-ENERGY ELECTRON-BEAMS IN PROTON SYNCHROTRONS
    BESSONOV, EG
    VAZDIK, YA
    SOVIET JOURNAL OF NUCLEAR PHYSICS-USSR, 1979, 29 (03): : 333 - 335
  • [22] THE PHYSICS OF INTRAOPERATIVE RADIOTHERAPY USING HIGH-ENERGY ELECTRON-BEAMS
    BIGGS, PJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 10-1 (MAY): : 1102 - 1106
  • [23] TRANSFORMATION HARDENING OF STEEL USING HIGH-ENERGY ELECTRON-BEAMS
    ELMER, JW
    NEWTON, MA
    SMITH, AC
    WELDING JOURNAL, 1994, 73 (12) : S291 - S299
  • [24] PRELIMINARY INVESTIGATIONS IN WATER TREATMENT WITH HIGH-ENERGY ELECTRON-BEAMS
    GALLIEN, C
    ICRE, P
    LEVAILLANT, C
    MONTIEL, A
    RADIATION PHYSICS AND CHEMISTRY, 1977, 9 (4-6): : 775 - 787
  • [25] NEW STANFORD FACILITY SQUEEZES HIGH-ENERGY ELECTRON-BEAMS
    SCHWARZSCHILD, B
    PHYSICS TODAY, 1994, 47 (07) : 22 - 22
  • [26] HEATING OF DENSE TARGET PLASMAS WITH HIGH-ENERGY ELECTRON-BEAMS
    THOMPSON, JR
    DROBOT, AT
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (10): : 1350 - 1350
  • [27] CORONA-PLASMA CATHODE FOR HIGH-ENERGY ELECTRON-BEAMS
    SHIELDS, H
    SANDSTROM, RL
    LEVATTER, JI
    APPLIED PHYSICS LETTERS, 1985, 47 (07) : 680 - 682
  • [28] CALIBRATION OF HIGH-ENERGY ELECTRON-BEAMS BY USE OF GRAPHITE CALORIMETERS
    HUMPHREYS, JC
    WALKER, ML
    PUHL, JM
    DICK, CE
    MCLAUGHLIN, WL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 83 (04): : 563 - 569
  • [29] ON THE POSSIBILITY OF USING HIGH-ENERGY ELECTRON-BEAMS FOR THE ALLOYING OF MATERIALS
    VLADIMIRSKII, RA
    LIVSHITS, VB
    PAYUK, VA
    PLOTNIKOV, VS
    KUZMINYKH, VA
    RUSSIAN METALLURGY, 1988, (05): : 128 - 134
  • [30] MERCURIC IODIDE DOSIMETER RESPONSE TO HIGH-ENERGY ELECTRON-BEAMS
    LOEWINGER, E
    NISSENBAUM, J
    SCHIEBER, MM
    APPLIED RADIATION AND ISOTOPES, 1988, 39 (07) : 667 - 669