CORRECTION FACTORS FOR FRICKE DOSIMETRY IN HIGH-ENERGY ELECTRON-BEAMS

被引:6
|
作者
MA, CM
NAHUM, AE
机构
[1] Inst. of Cancer Res., R. Marsden Hospital, Sutton
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1993年 / 38卷 / 03期
关键词
D O I
10.1088/0031-9155/38/3/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents Fricke-to-water dose conversion and wall correction factors for Fricke ferrous sulphate dosimetry in high-energy electron beams. The dose conversion factor has been calculated as the ratio of the mean dose in water to the mean dose in the Fricke solution with a water-walled vessel and the wall correction factor accounts for the change in the Fricke dose due to the presence of the non-water wall material. The EGS4 (Electron Gamma Shower version 4) Monte Carlo code system has been employed in this work together with the application of a correlated sampling variance reduction technique. The results show that for a Fricke dosimeter of 1.354 cm diameter and 5.5 cm length the dose conversion factor is nearly constant at 1.004 (within 0.1%) for electron energies of 11-25 MeV if the dosimeter is placed at the depth of maximum dose but can vary by a few per cent if the dosimeter is placed on the descending portion of the depth-dose curve. The wall corrections are smaller than 0.3% for 0.1 cm thick polystyrene vessels. For 0.1 cm thick Pyrex glass vessels the wall correction factor varies from 0.989 for 11 MeV at 2.75 cm depth to 0.997 for 25 MeV at 7 cm depth. This confirms recent experimental findings that Fricke doses obtained with glass-walled vessels were up to 1% higher than those with polystyrene-walled vessels.
引用
收藏
页码:423 / 438
页数:16
相关论文
共 50 条
  • [1] COMPARISON OF FERROUS SULFATE (FRICKE) AND IONIZATION DOSIMETRY FOR HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    KWA, W
    KORNELSEN, RO
    MEDICAL PHYSICS, 1990, 17 (04) : 602 - 606
  • [2] SWISS RECOMMENDATIONS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON BEAMS AND ELECTRON-BEAMS
    ANDRE, L
    VONARX, A
    CORD, I
    GARAVAGLIA, G
    JONESCU, F
    VALLEY, JF
    HELVETICA PHYSICA ACTA, 1987, 60 (02): : 262 - 262
  • [3] SWISS RECOMMENDATIONS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    GARAVAGLIA, G
    ANDRE, L
    ARX, AV
    CORDT, I
    IONESCU, F
    VALLEY, JF
    MEDICAL PHYSICS, 1986, 13 (04) : 575 - 575
  • [4] NEW PROTOCOLS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    DUTREIX, A
    MIJNHEER, B
    SVENSSON, H
    RADIOTHERAPY AND ONCOLOGY, 1985, 4 (04) : 289 - 290
  • [6] DOSIMETRY OF HIGH-ENERGY ELECTRON-BEAMS FROM A LINEAR-ACCELERATOR
    BRIOT, E
    DUTREIX, A
    JOURNAL DE RADIOLOGIE D ELECTROLOGIE ET DE MEDECINE NUCLEAIRE, 1976, 57 (05): : 447 - 454
  • [7] COLLIMATION OF HIGH-ENERGY ELECTRON-BEAMS
    LAX, I
    BRAHME, A
    ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (03): : 199 - 207
  • [8] SPECTROMETRY OF HIGH-ENERGY ELECTRON-BEAMS
    DOUGLAS, GW
    MACDONALD, JCF
    PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (02): : 312 - 312
  • [9] MONITORING OF HIGH-ENERGY ELECTRON-BEAMS
    STRATIENKO, VA
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1972, (06): : 28 - 30
  • [10] EVALUATION OF FILM AND THERMOLUMINESCENT DOSIMETRY OF HIGH-ENERGY ELECTRON-BEAMS IN HETEROGENEOUS PHANTOMS
    ELKHATIB, E
    ANTOLAK, J
    SCRIMGER, J
    MEDICAL PHYSICS, 1992, 19 (02) : 317 - 323