MEASUREMENT OF FOREARM ROTATION - THE TECHNIQUES, AND ITS REPRODUCIBILITY AND VALIDITY

被引:0
|
作者
VANDERVAART, AJM
机构
[1] Faculty of Industrial Design Engineering, Delft University of Technology, Delft, 2628 BX
来源
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS | 1994年 / 26卷 / 04期
关键词
D O I
10.3758/BF03204657
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Forearm rotation is a point of interest in the study of human movement. For the most part, earlier methods for determining this joint rotation could be applied only in restricted situations. In this paper, a new technique is described, which involves the use of a three-dimensional opto-electronic motion registration system. With only two cameras, the supination angle in almost every position can be determined. A bracelet is attached to the subject's forearm and fixed to the radius. Wrist points are defined in relation to this bracelet (in its local coordinate system). The properties of the bracelet allow the motion-registration system to calculate its position in the global coordinate system. Given the position of the bracelet, the shoulder, and the elbow, the rotation angle can be determined. The reproducibility (error less than 2-degrees) of and validity of the technique are also discussed.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [21] Validity and reproducibility of ultrasonography for the measurement of intra-abdominal adipose tissue
    RP Stolk
    O Wink
    PMJ Zelissen
    R Meijer
    APG van Gils
    DE Grobbee
    International Journal of Obesity, 2001, 25 : 1346 - 1351
  • [22] Forearm rotation + String basics
    Fischer, S
    STRAD, 1997, 108 (1288): : 866 - 867
  • [23] CONSTRUCT VALIDITY AND REPRODUCIBILITY OF HANDHELD ULTRASOUND DEVICES IN CAROTID ARTERY DIAMETER MEASUREMENT
    Willems, Loes
    Vermeulen, Jenske
    Wiegerinck, Anouk
    Fekkes, Stein
    Reijnen, Michel
    Warle, Michiel
    Dekorte, Chris
    Thijssen, Dick
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (03): : 866 - 874
  • [24] A MODIFIED FOREARM ROTATION SPLINT
    MAYNE, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (02): : 483 - 484
  • [25] THE AMPLITUDE OF FOREARM AND OF HUMERAL ROTATION
    SALTER, N
    DARCUS, HD
    JOURNAL OF ANATOMY, 1953, 87 (04) : 407 - 418
  • [26] The functional anatomy of forearm rotation
    Lees, Vivien C.
    JOURNAL OF HAND AND MICROSURGERY, 2009, 1 (02) : 92 - 99
  • [27] MEASUREMENT OF INTRAOCULAR-PRESSURE - STUDY OF ITS REPRODUCIBILITY
    PHELPS, CD
    PHELPS, GK
    ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1976, 198 (01): : 39 - 43
  • [28] Validity and Reliability of a Novel Instrument for the Measurement of Subtalar Joint Axis of Rotation
    Kim, Byong Hun
    Lee, Sae Yong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)
  • [29] EFFECTS OF RECORDING AND MEASUREMENT TECHNIQUES ON P3 LATENCY REPRODUCIBILITY
    ZAMRINI, EY
    MEADOR, KJ
    LORING, DW
    ABNEY, OL
    JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 1991, 13 (01) : 103 - 103
  • [30] Reproducibility of simplified techniques for the measurement of Cr-51-EDTA clearance
    Piepsz, A
    Tondeur, M
    Ham, HR
    NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (12) : 1065 - 1067