MEASUREMENT OF FOREARM ROTATION - THE TECHNIQUES, AND ITS REPRODUCIBILITY AND VALIDITY

被引:0
|
作者
VANDERVAART, AJM
机构
[1] Faculty of Industrial Design Engineering, Delft University of Technology, Delft, 2628 BX
来源
关键词
D O I
10.3758/BF03204657
中图分类号
B841 [心理学研究方法];
学科分类号
040201 ;
摘要
Forearm rotation is a point of interest in the study of human movement. For the most part, earlier methods for determining this joint rotation could be applied only in restricted situations. In this paper, a new technique is described, which involves the use of a three-dimensional opto-electronic motion registration system. With only two cameras, the supination angle in almost every position can be determined. A bracelet is attached to the subject's forearm and fixed to the radius. Wrist points are defined in relation to this bracelet (in its local coordinate system). The properties of the bracelet allow the motion-registration system to calculate its position in the global coordinate system. Given the position of the bracelet, the shoulder, and the elbow, the rotation angle can be determined. The reproducibility (error less than 2-degrees) of and validity of the technique are also discussed.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [1] MEASUREMENT OF FOREARM ROTATION - AN EVALUATION OF 2 TECHNIQUES
    MCGARRY, G
    GARDNER, E
    MUIRHEAD, A
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1988, 13B (03): : 288 - 290
  • [2] Evaluating the reproducibility and validity of maximal mouth opening measurement techniques
    Smeets, Maximiliaan
    Croonenborghs, Tomas-Marijn
    Van Dessel, Jeroen
    Jacobs, Reinhilde
    Willaert, Robin
    Bila, Michel
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2025, 126 (04)
  • [3] EFFECTS OF FOREARM POSITION ON MEASUREMENT OF GLENOHUMERAL ROTATION
    WHITE, DJ
    BREEN, JC
    PHYSICAL THERAPY, 1984, 64 (05): : 739 - 739
  • [4] VALIDITY OF BLOOD PRESSURE MEASUREMENT WITH CUFF IN ARM AND FOREARM
    FORSBERG, SA
    DEGUZMAN, M
    BERLIND, S
    ACTA MEDICA SCANDINAVICA, 1970, 188 (05): : 389 - +
  • [5] Validity, reliability and responsiveness of a goniometer watch to measure pure forearm rotation
    Harte, Daniel
    Nevill, Alan
    Ramsey, Lucia
    Martin, Suzanne
    HAND THERAPY, 2024, 29 (01) : 30 - 40
  • [6] The Effect of Rotation Angle on the Measurement of Bone Mineral Density in the Forearm
    Han, M.
    Kwon, S.
    Juhng, S.
    Yang, S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [7] Repeatability and Reproducibility techniques for the analysis of measurement systems
    Zanobini, Andrea
    Sereni, Bianca
    Catelani, Marcantonio
    Ciani, Lorenzo
    MEASUREMENT, 2016, 86 : 125 - 132
  • [8] ULTRASOUND MEASUREMENT OF MUSCLE THICKNESS AT THE PROXIMAL FOREARM: VALIDITY ISSUES
    Castell, Sonia
    Smerilli, Gianluca
    Cipolletta, Edoardo
    Salaffi, Fausto
    Filippucci, Emilio
    Grassi, Walter
    ANNALS OF THE RHEUMATIC DISEASES, 2019, 78 : 2027 - 2028
  • [9] Reproducibility and validity of ultrasound for the measurement of visceral and subcutaneous adipose tissues
    Schlecht, Inga
    Wiggermann, Philipp
    Behrens, Gundula
    Fischer, Beate
    Koch, Manja
    Freese, Johanna
    Rubin, Diana
    Noethlings, Ute
    Stroszczynski, Christian
    Leitzmann, Michael F.
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2014, 63 (12): : 1512 - 1519
  • [10] Validity and Reproducibility of Various Measurement Methods for Craniocervical Sagittal Balance
    Tamai, Koji
    Suzuki, Akinobu
    Takahashi, Shinji
    Hoshino, Masatoshi
    Toyoda, Hiromitsu
    Hayashi, Kazunori
    Ohyama, Shoichiro
    Kishimura, Yuichi
    Onode, Ema
    Umano, Masayuki
    Terai, Hidetomi
    Nakamura, Hiroaki
    CLINICAL SPINE SURGERY, 2018, 31 (02): : 80 - 85