CONVENTIONAL VS CO2 DEMAND-CONTROLLED VENTILATION SYSTEMS

被引:10
|
作者
HAGHIGHAT, F
DONNINI, G
机构
[1] Centre for Building Studies, Concordia University, Montreal, Que. H3G 1M8
关键词
CO2; DEMAND-CONTROLLED VENTILATION SYSTEMS; IAQ;
D O I
10.1016/0306-4565(93)90085-8
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
1. The feasibility of controlling the ventilation system using the occupant-generated carbon dioxide as an indicator of ventilation rate and indoor air quality has been investigated in an eleven storey office building. 2. The study compares the indoor environment created by two different types of ventilation control systems. 3. The two ventilation systems tested consisted of a conventional system controlled by outdoor temperatures, and a demand-controlled system regulated by indoor carbon dioxide concentration. 4. The results show that the CO2-based demand-controlled ventilation system does not worsen indoor. air quality and thermal comfort. It was also noticed that an energy saving of 12% was achieved using the CO2 control system. 5. The occupants perceived that their productivity is proportional to their perception of the indoor environment; indicating that higher productivity rates can be achieved by better controlling the working environment above satisfactory levels.
引用
收藏
页码:519 / 522
页数:4
相关论文
共 50 条
  • [31] Carbon dioxide (CO2) demand-controlled ventilation in university computer classrooms and possible effects on headache, fatigue and perceived indoor environment: an intervention study
    Dan Norbäck
    Klas Nordström
    Zhuohui Zhao
    [J]. International Archives of Occupational and Environmental Health, 2013, 86 : 199 - 209
  • [32] Model-Based Potential Analysis of Demand-Controlled Ventilation in Buildings
    Ben Jemaa, K.
    Kotman, P.
    Graichen, K.
    [J]. IFAC PAPERSONLINE, 2018, 51 (02): : 85 - 90
  • [33] Evaluation of demand-controlled ventilation and enthalpy exchangers in small commercial buildings
    Mercer, KB
    Braun, JE
    [J]. ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 873 - 889
  • [34] Minimum sensor grid density and configuration to enable CO2-based demand-controlled ventilation in an office building
    Hobson, Brodie W.
    Markus, Andre A.
    Gunay, H. Burak
    Rizvi, Farzeen
    [J]. ENERGY AND BUILDINGS, 2023, 298
  • [35] Intermittent demand-controlled ventilation for energy flexibility and indoor air quality
    Niu, Dun
    Li, Yuxin
    Zhang, Sheng
    Lin, Zhang
    [J]. BUILDING AND ENVIRONMENT, 2024, 263
  • [36] Carbon dioxide (CO2) demand-controlled ventilation in university computer classrooms and possible effects on headache, fatigue and perceived indoor environment: an intervention study
    Norback, Dan
    Nordstrom, Klas
    Zhao, Zhuohui
    [J]. INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2013, 86 (02) : 199 - 209
  • [37] Acceptable air velocities using demand-controlled ventilation for individual cooling
    Thunshelle, Kari
    Nordby, Henrik S.
    Solberg, Hakon Rikoll
    Holos, Sverre
    Schild, Peter G.
    [J]. 12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [38] Occupancy density and benefits of demand-controlled ventilation in Norwegian primary schools
    Mysen, M
    Berntsen, S
    Nafstad, P
    Schild, PG
    [J]. ENERGY AND BUILDINGS, 2005, 37 (12) : 1234 - 1240
  • [39] Composability Modeling for the Use Case of Demand-controlled Ventilation and Heating System
    Behravan, Ali
    Tabassam, Nadra
    Al -Najjar, Osama
    Obermaisser, Roman
    [J]. 2019 6TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT 2019), 2019, : 1998 - 2003