A METHOD TO DETERMINE THE ADEQUACY OF RESUSCITATION USING TISSUE OXYGEN MONITORING

被引:43
|
作者
WAXMAN, K
ANNAS, C
DAUGHTERS, K
TOMINAGA, GT
SCANNELL, G
机构
[1] Department of Surgery, University of California Irvine Medical Center, Orange
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 1994年 / 36卷 / 06期
关键词
D O I
10.1097/00005373-199406000-00016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The change in tissue PO2 in response to an increased inspired O2 challenge may be related to the state of cellular oxygenation, and hence the adequacy of resuscitation. To test this hypothesis, we measured tissue PO2 during inspired O2 challenges in 29 injured patients during acute resuscitation or intensive care unit monitoring. The O2 challenge test had 100% sensitivity and specificity in detecting flow-dependent O2 consumption in invasively monitored patients in the intensive care unit. During acute resuscitation, 60% of patients had negative initial O2 challenge test results, indicating that flow-dependent O2 consumption might have been present. Of nine such patients, five had subsequent positive O2 challenge test results after fluid resuscitation, indicating successful resuscitation. Four patients (27% of acute resuscitations), however, had repeatedly negative findings, possibly indicating persistent inadequate cellular oxygenation despite fluid resuscitation. Other commonly measured variables did not differentiate these patients. Monitoring of tissue PO2 during an inspired O2 challenge may be a useful test for determining the adequacy of resuscitation from hypovolemic shock.
引用
收藏
页码:852 / 856
页数:5
相关论文
共 50 条
  • [31] Noninvasive temperature monitoring using ultrasound tissue characterization method
    Pousek, Lubomir
    Jelinek, Matin
    Storkova, Blanka
    Novak, Petr
    ITI 2006: PROCEEDINGS OF THE 28TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY INTERFACES, 2006, : 219 - +
  • [32] Initial resuscitation bundle and monitoring tissue perfusion in severe sepsis
    Romero P, Carlos
    Hernandez P, Glenn
    REVISTA MEDICA DE CHILE, 2013, 141 (09) : 1173 - 1181
  • [33] TISSUE OXYGENATION AND OXYGEN CONSUMPTION FOLLOWING HEMORRHAGE AND RESUSCITATION USING A HEMOGLOBIN-BASED OXYGEN CARRIER AND HUMAN SERUM ALBUMIN
    Song, Bjorn K.
    Connery, Michael D.
    Moon-Massat, P.
    Pittman, Roland N.
    FASEB JOURNAL, 2009, 23
  • [34] A noninvasive photoplethysmographic method for assessing the adequacy of surface tissue circulation
    Mylrea, K.C.
    McVeigh, L.J.
    Bean, B.A.
    Malone, J.M.
    Journal of clinical engineering, 1986, 11 (02) : 135 - 143
  • [35] Animal studies using an oxygen-tension sensor for tissue viability monitoring
    Tanase, Dafina
    Komen, Niels
    Draaijer, Arle
    Lange, Johan F.
    Kleinrensink, Gert-Jan
    Jeekel, Johannes
    French, Paddy J.
    BIODEVICES 2008: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, VOL 1, 2008, : 50 - +
  • [36] Continuous monitoring of interstitial tissue oxygen using subcutaneous oxygen microsensors: In vivo characterization in healthy volunteers
    Kanick, Stephen C.
    Schneider, Peter A.
    Klitzman, Bruce
    Wisniewski, Natalie A.
    Rebrin, Kerstin
    MICROVASCULAR RESEARCH, 2019, 124 : 6 - 18
  • [37] Usefulness of near-infrared spectroscopy for monitoring a cerebral tissue oxygen saturation during cardio-pulmonary resuscitation (CPR)
    M Homma
    H Henmi
    Y Otomo
    J Inoue
    K Mashiko
    Y Yamamoto
    T Otsuka
    Critical Care, 1 (Suppl 1):
  • [38] Feasibility of Oxygen Saturation Monitoring During Neonatal Resuscitation in Indian Scenario
    Reddy, K. Sudarshan
    Venkataravanappa, Sainath T.
    Gururaja, Girish
    INDIAN PEDIATRICS, 2018, 55 (11) : 999 - 999
  • [39] Feasibility of Oxygen Saturation Monitoring During Neonatal Resuscitation in Indian Scenario
    K Sudarshan Reddy
    Sainath T Venkataravanappa
    Girish Gururaja
    Indian Pediatrics, 2018, 55 : 999 - 999
  • [40] TRANS-CUTANEOUS OXYGEN SENSORS FOR CONTINUOUS MONITORING IN SHOCK AND RESUSCITATION
    TREMPER, KK
    WAXMAN, K
    SHOEMAKER, WC
    CRITICAL CARE MEDICINE, 1979, 7 (03) : 136 - 136