INFERIOR VENA-CAVA OCCLUSION WITH PULMONARY-EMBOLISM BECAUSE OF COMPLICATIONS DUE TO RUPTURED ABDOMINAL ANEURYSM DEMONSTRATED BY RADIONUCLIDE VENOGRAPHY

被引:3
|
作者
OHNO, A
HAYASHIDA, K
MATSUI, H
NISHIMURA, T
机构
[1] OSAKA UNIV,SCH MED,BIOMED RES CTR,OSAKA 553,JAPAN
[2] NATL CARDIOVASC CTR,DEPT RADIOL,OSAKA,JAPAN
[3] NATL CARDIOVASC CTR,DEPT CARDIOL,OSAKA,JAPAN
关键词
D O I
10.1097/00003072-199505000-00013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 66-year-old man with an abdominal aortic aneurysm confirmed by CT had bilateral swelling of the lower extremities with pain radiating to the back, Radionuclide venography and pulmonary scintigraphy demonstrated occlusion of the inferior vena cava and multiple pulmonary emboli, with a hot spot in the liver, Surgery revealed a ruptured abdominal aortic aneurysm that occluded the inferior vena cava, fistula formation, and extensive thrombosis of the inferior vena cava proximal to the occlusion site. Radionuclide venography was useful in detecting venous obstruction and the collateral formation represented by the hot spot in the liver as complications of the ruptured abdominal aortic aneurysm, and in assessing the improvement of pulmonary embolism by medical therapy.
引用
收藏
页码:436 / 439
页数:4
相关论文
共 50 条
  • [31] USE OF INFERIOR VENA-CAVA FILTERS FOR PULMONARY-EMBOLISM PROPHYLAXIS IN PEDIATRIC-PATIENTS
    REED, RA
    TEITELBAUM, GP
    STANLEY, P
    MAZER, MJ
    TONKIN, IL
    ROLLINS, NK
    [J]. RADIOLOGY, 1992, 185 : 231 - 231
  • [32] USE OF THE INFERIOR VENA-CAVA CLIP IN PATIENTS AT HIGH-RISK FOR PULMONARY-EMBOLISM
    HEAPS, JM
    LAGASSE, LD
    [J]. GYNECOLOGIC ONCOLOGY, 1990, 39 (03) : 277 - 283
  • [33] PARADOXICAL PULMONARY-EMBOLISM - MIGRATION OF AN INFERIOR VENA-CAVA FILTER - REPORT OF 2 CASES
    GLOCK, Y
    ROUX, D
    [J]. ANNALES DE CHIRURGIE, 1993, 47 (02): : 157 - 160
  • [34] RECURRENT, FATAL PULMONARY-EMBOLISM DESPITE INFERIOR VENA-CAVA INTERRUPTION WITH THE GREENFIELD FILTER
    BOUNAMEAUX, H
    VELEBIT, V
    BATTIKHA, J
    SCHNEIDER, PA
    BISETTI, A
    KRAHENBUHL, B
    [J]. VASA-JOURNAL OF VASCULAR DISEASES, 1987, 16 (01): : 84 - 85
  • [35] Ruptured Abdominal Aortic Aneurysm with a Duplicated Inferior Vena Cava
    Nishimura, Kengo
    Hamasaki, Takafumi
    Ota, Rikako
    Matsuoka, Yuki
    Kodama, Wataru
    Fukino, Syunsuke
    [J]. ANNALS OF VASCULAR DISEASES, 2019, 12 (03) : 401 - 403
  • [36] INFERIOR VENA-CAVA OCCLUSION SECONDARY TO AORTIC-ANEURYSM
    PALMER, MA
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1990, 31 (03): : 372 - 374
  • [37] DOUBLE INFERIOR VENA-CAVA AND ABDOMINAL AORTIC-ANEURYSM
    HANS, SS
    GORDON, M
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1985, 26 (01): : 76 - 78
  • [39] PERCUTANEOUS TRANSCATHETER FILTER FOR THE INFERIOR VENA-CAVA - A NEW DEVICE FOR TREATMENT OF PATIENTS WITH PULMONARY-EMBOLISM
    ROEHM, JOF
    GIANTURCO, C
    BARTH, MH
    WRIGHT, KC
    [J]. RADIOLOGY, 1984, 150 (01) : 255 - 257
  • [40] COMPARISON BETWEEN PARTIAL AND COMPLETE LIGATION OF INFERIOR VENA-CAVA FOR PREVENTION OF RECURRENT PULMONARY-EMBOLISM
    ANTEBI, E
    SHOCHAT, I
    SARELI, P
    GELTNER, D
    DEUTSCH, V
    MOZES, M
    [J]. ISRAEL JOURNAL OF MEDICAL SCIENCES, 1975, 11 (2-3): : 294 - 298