FLOW-INJECTION AMPEROMETRIC DETERMINATION OF CYANIDE ON A MODIFIED SILVER ELECTRODE

被引:14
|
作者
NIKOLIC, SD
MILOSAVLJEVIC, EB
HENDRIX, JL
NELSON, JH
机构
[1] UNIV NEVADA, MACKAY SCH MINES, DEPT CHEM, RENO, NV 89557 USA
[2] UNIV NEVADA, MACKAY SCH MINES, DEPT CHEM & MET ENGN, RENO, NV 89557 USA
关键词
FLOW INJECTION; AMPEROMETRIC DETECTION; MODIFIED SILVER ELECTRODE; CYANIDE DETERMINATION;
D O I
10.1039/an9921700047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A composite coating based on a mixture of phosphatidylcholine, cholesterol and stearic acid was used for fabricating a silver-based amperometric sensor. The sensor was used in a flow injection (Fl) configuration for the selective and sensitive determination of cyanide. The method is based on the permselectivity of the lipid membrane, which rejects from the surface of the working silver electrode the undesired, potentially interfering species, while allowing the transport of the analyte as hydrogen cyanide. Logarithmic calibration graphs were linear up to the maximum concentration of CN- investigated (0.100 mmol dm-3). The precision of the technique was better than a relative standard deviation of 3.5% at the 0.5-mu-mol dm-3 leve land better than 2% at the 0.1 mmol dm-3 level, with a throughput of 30 samples h-1. Under optimum conditions, the detection limit was 0.1-mu-mol dm-3 (0.26 ng CN-). The effects of working potential, type of electrode coating, acidity of the reagent stream and interferents on the Fl signals were studied.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 50 条
  • [31] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    [J]. ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [32] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF DIFFUSION-COEFFICIENTS
    YANG, JN
    YAO, ZH
    GAO, ZP
    [J]. ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 341 - 346
  • [33] AMPEROMETRIC ENZYME ELECTRODE SYSTEM FOR THE FLOW-INJECTION ANALYSIS OF GLUCOSE
    MOODY, GJ
    SANGHERA, GS
    THOMAS, JDR
    [J]. ANALYST, 1986, 111 (06) : 605 - 609
  • [34] THE VIBRATING WIRE ELECTRODE AS AN AMPEROMETRIC DETECTOR FOR FLOW-INJECTION SYSTEMS
    PRATT, KW
    JOHNSON, DC
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 87 - 101
  • [35] COBALT(II, III)-OXIDE CHEMICALLY MODIFIED ELECTRODE AS AMPEROMETRIC DETECTOR IN FLOW-INJECTION SYSTEMS
    MANNINO, S
    COSIO, MS
    RATI, S
    [J]. ELECTROANALYSIS, 1993, 5 (02) : 145 - 148
  • [37] Determination of cyanide using flow-injection multisensor system
    Ipatov, A
    Ivanov, M
    Makarychev-Mikhailov, S
    Kolodnikov, V
    Legin, A
    Vlasov, Y
    [J]. TALANTA, 2002, 58 (06) : 1071 - 1076
  • [38] Fluorimetric determination of free cyanide by flow-injection analysis
    Beck, HP
    Zhang, B
    Bordeanu, A
    [J]. ANALYTICAL LETTERS, 2003, 36 (10) : 2211 - 2228
  • [39] SPECTROFLUOROMETRIC DETERMINATION OF CYANIDE AND THIOCYANATE BASED ON A MODIFIED KONIG REACTION IN A FLOW-INJECTION SYSTEM
    TANAKA, A
    DEGUCHI, K
    DEGUCHI, T
    [J]. ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 281 - 286
  • [40] ADualScreen-Printed Electrode with Palladium Nanoparticles for the Flow-Injection Amperometric Determination of Dopamine and Adrenaline
    Shaidarova, L. G.
    Chelnokova, I. A.
    Leksina, Yu. A.
    Gedmina, A. V.
    Budnikov, H. C.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (08) : 1059 - 1065