ELECTROSPRAY TANDEM MASS-SPECTROMETRY FOR ANALYSIS OF NATIVE MURAMIC ACID IN WHOLE BACTERIAL-CELL HYDROLYSATES

被引:30
|
作者
BLACK, GE
FOX, A
FOX, K
SNYDER, AP
SMITH, PBW
机构
[1] UNIV S CAROLINA,SCH MED,COLUMBIA,SC 29208
[2] USA CHEM RES,CTR DEV & ENGN,ABERDEEN PROVING GROUND,MD 21010
[3] GEOCENTERS INC,GUNPOWDER BRANCH,ABERDEEN PROVING GROUND,MD 21010
关键词
D O I
10.1021/ac00095a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Muramic acid is an amino sugar found in eubacterial cell walls and not elsewhere in nature. This study explored the use of electrospray tandem mass spectrometry (ESI MS/MS) in analysis of underivatized muramic acid in bacterial hydrolysates. Fungal hydrolysates were used as negative controls. The only processing used was hydrolysis in sulfuric acid followed by extraction with an organic base (N,N-dioctylmethylamine) to remove the acid prior to ESI MS/MS analysis. Compared with pure muramic acid, bacterial hydrolysates produced more complex ESI mass spectra, such that the protonated molecular ion at m/z 252 was barely detectable. In contrast, product ion spectra of m/z 252 were identical among pure muramic acid, Gram positive bacteria, and Gram negative bacteria. However, no characteristic product ion spectrum was manifested from m/z 252 in fungal samples. This allowed ready, visual differentiation of bacteria and fungi. Multiple reaction monitoring (MRM) following muramic acid fragmentations (m/z 252 --> 144 and m/z 252 --> 126) increased sensitivity and allowed quantitative differentiation when compared with the MRM of the internal standard N-methyl-D-glucamine (m/z 196 --> 44). ESI MS/MS required minimal sample preparation and allowed rapid sample throughput for analysis of muramic acid in whole bacterial cell hydrolysates.
引用
收藏
页码:4171 / 4176
页数:6
相关论文
共 50 条
  • [31] HYBRID TANDEM MASS-SPECTROMETRY OF ELECTROSPRAY-PRODUCED PEPTIDE IONS
    TOMER, KB
    MCGOWN, SR
    DETERDING, LJ
    ORGANIC MASS SPECTROMETRY, 1993, 28 (05): : 534 - 541
  • [32] ELECTROSPRAY TANDEM MASS-SPECTROMETRY OF OXO COMPLEXES OF CHROMIUM, MANGANESE AND RUTHENIUM
    LAU, TC
    WANG, JY
    SIU, KWM
    GUEVREMONT, R
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (12) : 1487 - 1488
  • [33] CONFIRMATION AND QUANTITATION OF HYDROXYMETHANESULFONATE IN PRECIPITATION BY ELECTROSPRAY IONIZATION TANDEM MASS-SPECTROMETRY
    CHAPMAN, EG
    BARINAGA, CJ
    UDSETH, HR
    SMITH, RD
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1990, 24 (12): : 2951 - 2957
  • [34] CHARACTERIZATION OF N-LINKED OLIGOSACCHARIDES BY ELECTROSPRAY AND TANDEM MASS-SPECTROMETRY
    DUFFIN, KL
    WELPLY, JK
    HUANG, E
    HENION, JD
    ANALYTICAL CHEMISTRY, 1992, 64 (13) : 1440 - 1448
  • [35] Selective detection of lactolated peptides in hydrolysates by liquid chromatography electrospray tandem mass spectrometry
    Mollé, D
    Morgan, F
    Bouhallab, S
    Léonil, J
    ANALYTICAL BIOCHEMISTRY, 1998, 259 (01) : 152 - 161
  • [36] PEPTIDE SEQUENCE-ANALYSIS BY ELECTROSPRAY QUADRUPOLE ION-TRAP TANDEM MASS-SPECTROMETRY
    YATES, NA
    SHABANOWITZ, J
    HUNT, DF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 132 - ANYL
  • [37] PEPTIDE AND PROTEIN-ANALYSIS BY ELECTROSPRAY IONIZATION MASS-SPECTROMETRY AND CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY
    LOO, JA
    UDSETH, HR
    SMITH, RD
    ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) : 404 - 412
  • [38] DIRECT ANALYSIS OF LICHENS BY TANDEM MASS-SPECTROMETRY
    TABACCHI, R
    ALLEMAND, P
    TSOUPRAS, G
    SYMBIOSIS, 1991, 11 (2-3) : 193 - 206
  • [39] PHARMACEUTICAL AND CLINICAL ANALYSIS BY TANDEM MASS-SPECTROMETRY
    YOST, RA
    PERCHALSKI, RJ
    BROTHERTON, HO
    JOHNSON, JV
    BUDD, MB
    TALANTA, 1984, 31 (10) : 929 - 935
  • [40] ANALYSIS OF CYCLODEXTRINS USING FAST ATOM BOMBARDMENT MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY
    VOYKSNER, RD
    WILLIAMS, FP
    SMITH, CS
    KOBLE, DL
    SELTZMAN, HH
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (12): : 1071 - 1078