Role of Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation - from Pre-procedural Planning to Detection of Post-procedural Complications

被引:0
|
作者
Vecsey-Nagy, Milan [1 ,3 ]
Simon, Judit [1 ,3 ]
Szilveszter, Balint [1 ,3 ]
Karady, Julia [1 ,2 ,4 ]
Jermendy, Adam [1 ,3 ]
Merkely, Bela [1 ,3 ]
Maurovich-Horvat, Pal [1 ,3 ]
机构
[1] Semmelweis Univ, Cardiovasc Imaging Res Grp, Heart & Vasc Ctr, Budapest, Hungary
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Cardiac MR PET CT Program, Boston, MA USA
[3] Varosmajor U 68, H-1122 Budapest, Hungary
[4] Massachusetts Gen Hosp, 55 Fruit St, Boston, MA 02114 USA
来源
关键词
transcatheter aortic valve implantation; multidetector computed tomography; pre- and post-procedural assessment; major cardiac emergencies;
D O I
10.2478/jce-2018-0022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) is an effective treatment option for patients suffering from symptomatic, severe aortic valve stenosis. Previously, only patients with prohibitive or high surgical risk were TAVI candidates; however, current guidelines already recommend TAVI as a treatment alternative for patients with intermediate surgical risk. Multidetector computed tomography (MDCT) has gained great importance in the periprocedural assessment of patients who undergo TAVI. Due to the three-dimensional image visualization, MDCT allows the evaluation of anatomical structures in a more comprehensive manner compared to echocardiography, the traditional tool used in TAVI patient work-up. By providing accurate measurements of the aortic root, MDCT helps to avoid potential patient-prosthesis mismatch throughout transcatheter valve sizing. Moreover, MDCT is also a feasible tool for access route evaluation and to determine the optimal projection angles for the TAVI procedure. Although the routine MDCT follow-up of patients is currently not recommended in clinical practice, if performed, it could provide invaluable information about valve integrity and asymptomatic leaflet thrombosis. Post-procedural MDCT can provide details about the position of the prosthesis and complications such as leaflet-thrombosis, aortic regurgitation, coronary occlusion, and other vascular complications that can represent major cardiac emergencies. The aim of the current review is to overview the role of MDCT in the pre- and post-procedural assessment of TAVI patients. In the first part, the article presents the role of pre-TAVI imaging in the complex anatomical assessment of the aortic valve and the selection of the most appropriate device. The second part of the review describes the role of MDCT in patients who underwent TAVI to assess potential complications, some of them leading to a major cardiovascular emergency.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 50 条
  • [41] Post-procedural fever after transcatheter aortic valve implantation: a retrospective single-centre study
    Scheggi, V.
    Del Pace, S.
    Fumagalli, C.
    Meucci, F.
    Nardi, G.
    Di Muro, F. M.
    Menale, S.
    Pisani, E.
    Vitiello, V. S.
    Setti, V.
    Valenti, R.
    Cerillo, A.
    Stefano, P. L.
    Di Mario, C.
    Marchionni, N.
    JOURNAL OF HOSPITAL INFECTION, 2024, 144 : 151 - 153
  • [42] Incidence and Management of Procedural Complications Associated with Transcatheter Aortic Valve Implantation
    Masson, Jean-Bernard
    Altwegg, Lukas A.
    Al Ali, Abdullah
    Al Bugami, Saad
    Boone, Robert H.
    Carere, Ronald G.
    Lichtenstein, Sam V.
    Cheung, Anson
    Moss, Robert
    Munt, Brad
    Thompson, Christopher R.
    Ye, Jian
    Webb, John G.
    CIRCULATION, 2008, 118 (18) : S808 - S808
  • [43] Predictive Role of Aortic Valve Calcium score on post-procedural outcomes and mortality after Transcatheter aortic valve replacement
    Taskesen, T.
    Ahsan, M.
    Putz, J.
    Park, A.
    De Santis, T.
    Latif, A.
    Ugwu, J.
    Ellerman, M.
    Shivapour, D.
    Chawla, A.
    McAllister, D.
    Sigurdsson, G.
    Martin, E.
    EUROPEAN HEART JOURNAL, 2022, 43 : 1577 - 1577
  • [44] The role of cardiovascular magnetic resonance in the assessment of severe aortic stenosis and in post-procedural evaluation following transcatheter aortic valve implantation and surgical aortic valve replacement
    Al Musa, Tarique
    Plein, Sven
    Greenwood, John P.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2016, 6 (03) : 259 - 273
  • [45] CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients
    Marwan, Mohamed
    Achenbach, Stephan
    Ensminger, Stefan M.
    Pflederer, Tobias
    Ropers, Dieter
    Ludwig, Josef
    Weyand, Michael
    Daniel, Werner G.
    Arnold, Martin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1191 - 1198
  • [46] CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients
    Mohamed Marwan
    Stephan Achenbach
    Stefan M. Ensminger
    Tobias Pflederer
    Dieter Ropers
    Josef Ludwig
    Michael Weyand
    Werner G. Daniel
    Martin Arnold
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1191 - 1198
  • [47] THE ROLE OF ADEQUATE PRE-PROCEDURAL PLANNING AND CORONARY PROTECTION IN THE PRESENCE OF HIGH RISK OF ACUTE CORONARY OCCLUSION AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION.
    Montonati, C.
    Fabris, T.
    Fraccaro, C.
    Pavei, A.
    Masiero, G.
    Tarantini, G.
    Napodano, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0G) : G10 - G11
  • [48] The impact of post-procedural complications on reimbursement, length of stay and mechanical ventilation among patients undergoing transcatheter aortic valve implantation in Germany
    Klaus Kaier
    Holger Reinecke
    Huseyin Naci
    Lutz Frankenstein
    Martin Bode
    Werner Vach
    Philip Hehn
    Andreas Zirlik
    Manfred Zehender
    Jochen Reinöhl
    The European Journal of Health Economics, 2018, 19 : 223 - 228
  • [49] Prognostic value of pre-procedural left ventricular strain for clinical events after transcatheter aortic valve implantation
    Suzuki-Eguchi, Noriko
    Murata, Mitsushige
    Itabashi, Yuji
    Shirakawa, Kousuke
    Fukuda, Memori
    Endo, Jin
    Tsuruta, Hikaru
    Arai, Takahide
    Hayashida, Kentaro
    Shimizu, Hideyuki
    Fukuda, Keiichi
    PLOS ONE, 2018, 13 (10):
  • [50] Multidetector computed tomography evaluation of candidates for transcatheter aortic valve implantation
    Guillen Subiran, M. E.
    Ros Mendoza, L. H.
    Angulo Hervias, E.
    Yaguee Romeo, D.
    Nunez Motilva, M. E.
    RADIOLOGIA, 2018, 60 (01): : 24 - 38