Fetal Arrhythmias and Related Fetal and Neonatal Outcomes

被引:0
|
作者
Abbasalizadeh, Fatemeh [1 ]
Abbasalizadeh, Shamsi [1 ]
Ghaffari, Shamsi [2 ]
Hesami, Rabee [3 ]
Hesmai, Leyla [1 ]
机构
[1] Tabriz Univ Med Sci, Womens Reprod Hlth Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Cardiovasc Res Ctr, Tabriz, Iran
[3] Urmia Univ Med Sci, Orumiyeh, Iran
关键词
Arrhythmia; Echocardiography; Fetal monitoring; Hydrops fetalis; Perinatal mortality;
D O I
10.15296/ijwhr.2016.30
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: Fetal cardiac arrhythmia has good prognosis. However, some can lead to hydrops fetalis and perinatal mortality. There are not sufficient studies on the prevalence and complications of fetal arrhythmias in Iran, thus, making parents anxious. Therefore, we performed this study to determine its proper management and to prevent its complications during pregnancy. Then we can help parents by giving them sufficient information about their fetal problem. Materials and Methods: This descriptive-analytic study included 81 pregnant women with fetal arrhythmia detected in routine monitoring. For cases, we performed fetal echocardiography. Data was analyzed by SPSS 20 (P < 0.05). Results: This study assessed the fetal period until 28 days after labor. Fetal arrhythmia was confirmed in 37 cases through echocardiography. The most prevalent arrhythmia was extrasystole with 27 cases (72.97%). Two cases with congenital heart disease experienced heart failure and hydrops fetalis and died in neonatal period and 25 cases survived. Eight cases had bradycardia including 5 with sinus bradycardia and 3 with atrioventricular block. Seven cases had congenital heart problems and 4 of them led to heart failure. Perinatal mortality was seen in six cases. Tachycardia was seen in two cases (5.4%) with no heart failure or hydrops fetalis. One case died of preterm delivery. Conclusion: Congenital heart disease is considered as an important risk, affecting fetal and neonatal outcome in fetuses with arrhythmias. As pregnancy advances, the frequency of arrhythmias decreased and converted to sinus rhythm.
引用
收藏
页码:130 / 133
页数:4
相关论文
共 50 条
  • [31] FETAL AND NEONATAL DISORDERS RELATED TO MATERNAL SMOKING
    NAEYE, R
    PEDIATRIC RESEARCH, 1978, 12 (04) : 517 - 517
  • [32] FETAL AND NEONATAL PATHOLOGY RELATED TO CHORIOANGIOMA OF PLACENTA
    MESSER, J
    VORS, J
    KRUG, JP
    PHILIPPE, E
    WILLARD, D
    SEMAINE DES HOPITAUX, 1974, 50 (49): : 891 - 897
  • [33] Fetal and neonatal complications related to prolonged pregnancy
    Chantry, A. A.
    Lopez, E.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2011, 40 (08): : 717 - 725
  • [34] FETAL AND NEONATAL RISKS RELATED TO CESAREAN SECTION
    STUDDIFORD, WE
    DECKER, WH
    BULLETIN OF THE NEW YORK ACADEMY OF MEDICINE, 1952, 28 (10) : 640 - 654
  • [35] FETAL AND NEONATAL CONDITION RELATED TO EPIDURAL ANALGESIA
    SPENCER, JAD
    KOUTSOUKIS, M
    LEE, A
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (12): : 1306 - 1307
  • [36] EVALUATION OF FETAL CARDIAC-ARRHYTHMIAS - ULTRASOUND FINDINGS AND NEONATAL OUTCOME
    CALVIN, SE
    GAZIANO, EP
    BENDEL, RP
    KNOX, GE
    BRANDT, DG
    MINNESOTA MEDICINE, 1992, 75 (12) : 29 - 31
  • [37] Adverse fetal/neonatal and obstetric outcomes in pregnancies with both maternal and fetal heart disease
    Fernandez-Campos, Beatriz A.
    Grewal, Jasmine
    Kiess, Marla
    Siu, Samuel C.
    Pfaller, Birgit
    Sermer, Mathew
    Mason, Jennifer
    Silversides, Candice K.
    Haberer, Kim
    JOURNAL OF PERINATOLOGY, 2024, 44 (10) : 1424 - 1431
  • [38] FETAL ARRHYTHMIAS - EVALUATION BY FETAL ECHOCARDIOGRAPHY AND TRANSPLACENTAL TREATMENT
    RIKITAKE, N
    TOYODA, O
    YOKOCHI, K
    KATO, H
    MATSUNAGA, T
    IDE, N
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (08): : 705 - 705
  • [39] Electronic fetal heart rate monitoring: Early neonatal outcomes associated with normal rate, fetal stress, and fetal distress
    Dellinger, EH
    Boehm, FH
    Crane, MM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 182 (01) : 214 - 220
  • [40] US evaluation of fetal growth: Prediction of neonatal outcomes
    Smith-Bindman, R
    Chu, PW
    Ecker, JL
    Feldstein, VA
    Filly, RA
    Bacchetti, P
    RADIOLOGY, 2002, 223 (01) : 153 - 161