RADIATION-DAMAGE BY NEUTRONS AND PHOTONS TO SILICON DETECTORS

被引:61
|
作者
GILL, K [1 ]
HALL, G [1 ]
ROE, S [1 ]
SOTTHIBANDHU, S [1 ]
WHEADON, R [1 ]
GIUBELLINO, P [1 ]
RAMELLO, L [1 ]
机构
[1] IST NAZL FIS NUCL,TURIN,ITALY
关键词
D O I
10.1016/0168-9002(92)90027-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Observations have been made of the behaviour of silicon diodes and microstrip detectors after exposures of up to 2 X 10(14) neutrons cm-2 and 4 Mrad Co-60 photons. Results are presented on leakage currents and doping concentration of the substrate material of neutron damaged devices. Important changes in the effective doping of the substrate have been observed to take place during the room temperature annealing of the material, particularly after high neutron fluences. Over times of more than one year further doping changes occur which increase the depletion voltage of type inverted material and may set an ultimate lifetime limit for silicon detectors in future hadron colliders. Measurements have been made of the performance of double sided microstrip detectors constructed using a field plate isolation technique on the n-type surface. After high doses of both neutrons and photons good interstrip isolation is maintained, demonstrating one potential technique for radiation tolerant microstrip fabrication.
引用
收藏
页码:177 / 188
页数:12
相关论文
共 50 条
  • [31] RADIATION-DAMAGE BY HIGH-ENERGY NEUTRONS
    PRIMAK, W
    NUCLEAR SCIENCE AND ENGINEERING, 1980, 73 (01) : 29 - 34
  • [32] RADIATION-DAMAGE ANNEALING MODELS IN GLASS DETECTORS
    SINGH, G
    VIRK, HS
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1990, 114 (1-2): : 51 - 62
  • [33] RADIATION-DAMAGE EFFECTS FROM 2 MEV PROTONS IN SILICON SURFACE BARRIER DETECTORS
    GRUBE, R
    LINDSTRO.G
    FRETWURS.E
    NUCLEAR INSTRUMENTS & METHODS, 1972, 101 (01): : 97 - &
  • [34] Radiation damage to silicon detectors
    Hall, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 368 (01): : 199 - 204
  • [35] Radiation damage in silicon detectors
    Lindström, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (1-2): : 30 - 43
  • [36] STABILIZATION OF RADIATION-DAMAGE IN A SILICON DIODE RADIATION DETECTOR
    JONES, D
    SCHUMACHER, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (01): : 109 - 110
  • [37] PROTON-INDUCED RADIATION-DAMAGE IN GERMANIUM DETECTORS
    BRUCKNER, J
    KORFER, M
    WANKE, H
    SCHROEDER, ANF
    FILGES, D
    DRAGOVITSCH, P
    ENGLERT, PAJ
    STARR, R
    TROMBKA, JI
    TAYLOR, I
    DRAKE, DM
    SHUNK, ER
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 209 - 217
  • [38] RADIATION-DAMAGE FACTOR FOR ION-IMPLANTED SILICON DETECTORS IRRADIATED WITH HEAVY-IONS
    KUROKAWA, M
    MOTOBAYASHI, T
    IEKI, K
    SHIMOURA, S
    MURAKAMI, H
    IKEDA, Y
    MORIYA, S
    YANAGISAWA, Y
    NOMURA, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (03) : 163 - 166
  • [39] FAST-NEUTRON RADIATION-DAMAGE EFFECTS ON HIGH-RESISTIVITY SILICON JUNCTION DETECTORS
    LI, Z
    KRANER, HW
    JOURNAL OF ELECTRONIC MATERIALS, 1992, 21 (07) : 701 - 705
  • [40] RADIATION-DAMAGE STUDIES ON SINGLE-SIDED AND DOUBLE-SIDED SILICON MICROSTRIP DETECTORS
    WHEADON, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 449 - 453