SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES

被引:42
|
作者
ECONOMOU, A [1 ]
FIELDEN, PR [1 ]
机构
[1] UMIST,DEPT INSTRUMENTAT & ANALYT SCI,POB 88,MANCHESTER M60 1QD,ENGLAND
关键词
STRIPPING VOLTAMMETRY; MERCURY FILM ELECTRODES;
D O I
10.1016/0003-2670(93)80141-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper the relative advantages of using square wave adsorptive stripping voltammetry in combination with a mercury film electrode as the working electrode were assessed. it was found that the resulting technique is fast, sensitive, offers excellent discrimination against the background current and can be used without deoxygenation of the sample; the analytical applications of the technique are demonstrated for the determination of Ni(II) with a limit of detection of 0.85 nmol l-1 and a linear range of 3 orders of magnitude (for 60 s preconcentration) and for the determination of Cu(II) in the nmol l-1 concentration level in the presence of dissolved oxygen.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [31] Electrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry
    Mariola Brycht
    Agnieszka Nosal-Wiercińska
    Karolina Sipa
    Konrad Rudnicki
    Sławomira Skrzypek
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 463 - 472
  • [32] SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY OF MOLYBDENUM(VI) IN CONTINUOUS-FLOW AT A WALL-JET MERCURY FILM ELECTRODE SENSOR
    NETO, MMPM
    ROCHA, MMGS
    BRETT, CMA
    TALANTA, 1994, 41 (09) : 1597 - 1601
  • [33] SIMULTANEOUS DETERMINATION OF NICKEL(II) AND COBALT(II) BY SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON A ROTATING-DISK MERCURY FILM ELECTRODE
    ECONOMOU, A
    FIELDEN, PR
    ANALYST, 1993, 118 (01) : 47 - 51
  • [34] Electrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry
    Brycht, Mariola
    Nosal-Wiercinska, Agnieszka
    Sipa, Karolina
    Rudnicki, Konrad
    Skrzypek, Slawomira
    MONATSHEFTE FUR CHEMIE, 2017, 148 (03): : 463 - 472
  • [35] Lead determination in canned food by square-wave adsorptive cathodic stripping voltammetry
    Wararattananurak, Puchong
    Chooto, Pipat
    Sherdshoopongse, Panit
    Chuaynukool, Chatjira
    Innuphat, Chalermpol
    SCIENCEASIA, 2014, 40 (05): : 355 - 361
  • [36] STUDY OF THE ADSORPTIVE STRIPPING SQUARE-WAVE VOLTAMMETRY OF BOVINE SERUM-ALBUMIN
    FLORES, JR
    MARIN, C
    GONZALEZ, E
    PARIENTE, F
    LORENZO, E
    ELECTROANALYSIS, 1991, 3 (4-5) : 405 - 408
  • [37] Electro-oxidation and determination of benomyl by square-wave adsorptive stripping voltammetry
    Inam, R. (rinam@gazi.edu.tr), 1600, AOAC International (97):
  • [38] SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY OF MENADIONE (VITAMIN-K3)
    VIRE, JC
    ELMAALI, NA
    PATRIARCHE, GJ
    CHRISTIAN, GD
    TALANTA, 1988, 35 (12) : 997 - 1000
  • [39] Behavior and quantification studies of amiloride drug using cyclic and square-wave adsorptive stripping voltammetry at a mercury electrode
    Hammam, E
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) : 1109 - 1116
  • [40] LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes
    Economou, A
    Voulgaropoulos, A
    JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2003, 25 (06): : 133 - 140