THE INFLUENCE OF EXPOSURE DURATION IN TRANSSCLERAL ND-YAG LASER CYCLOPHOTOCOAGULATION

被引:19
|
作者
PRUM, BE [1 ]
SHIELDS, SR [1 ]
SIMMONS, RB [1 ]
ECHELMAN, DA [1 ]
SHIELDS, MB [1 ]
机构
[1] DUKE UNIV,CTR EYE,DEPT OPHTHALMOL,POB 3802,DURHAM,NC 27710
关键词
D O I
10.1016/S0002-9394(14)74483-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Transscleral cyclophotocoagulation was performed in human autopsy eyes by using three Nd:YAG lasers with different durations of exposure: a pulsed, contact laser with a duration of 0.75 millisecond and a range of one to ten pulses per burst (GLase 106, Sunrise Technologies, Fremont, California); a pulsed, noncontact laser with a duration of 20 milliseconds (Microruptor 2, Lasag Medical Lasers, Thun Switzerland); and a continuous-wave, contact laser with durations of 700 and 2,000 milliseconds (Microruptor 3, Lasag Medical Lasers, Thun, Switzerland). Tissue responses were observed with a high-magnification videographic recording technique to analyze the immediate, real-time laser effects, and by light microscopy to characterize the laser-induced lesions further. Videographically, both pulsed lasers were noted to cause mild whitening of the pigment epithelium with frequent vaporization and explosive tissue disintegration. Histologically, the 0.75-millisecond pulse typically produced the most marked epithelial disruption, referred to as an explosive-like lesion, whereas the 20-millisecond pulse more often caused moderate tissue disruption with elevation of the epithelial layers in a blister-like lesion. In contrast, the continuous-wave laser was observed videographically to produce prominent tissue whitening and puckering, seen histologically as convolution of the epithelium and coagulation of stroma, which was called a shrinkage-like lesion. Our study suggests that exposure duration influences in vitro tissue response to transscleral Nd:YAG cyclophotocoagulation, although in vivo studies and clinical trials are needed to determine which tissue response is optimum for clinical use.
引用
收藏
页码:560 / 567
页数:8
相关论文
共 50 条
  • [21] TRANSSCLERAL RETINOPEXY WITH A CW ND-YAG LASER
    MESSMER, E
    FANKHAUSER, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S849 - S849
  • [22] HISTOPATHOLOGICAL TIME COURSE AFTER CONTACT TRANSSCLERAL ND-YAG LASER CYCLOPHOTOCOAGULATION (CYC) IN PIGMENTED RABBITS
    FRIEDMAN, AH
    SCHMIDT, KG
    CAMRAS, CB
    PODOS, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1197 - 1197
  • [23] TREATMENT OF REFRACTORY GLAUCOMA WITH ND-YAG LASER CYCLOPHOTOCOAGULATION
    KOPEL, J
    VALTOT, F
    POIRIER, C
    MOULIN, F
    MOREL, C
    HAUT, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1995, 18 (01): : 13 - 21
  • [24] PROBE ORIENTATION IN CONTACT ND-YAG LASER CYCLOPHOTOCOAGULATION
    BLOOM, M
    WEBER, PA
    OPHTHALMIC SURGERY AND LASERS, 1992, 23 (05): : 364 - 366
  • [25] PULSED VERSUS CONTINUOUS-WAVE TRANSSCLERAL ND-YAG CYCLOPHOTOCOAGULATION - A HISTOPATHOLOGIC STUDY
    SIMMONS, RB
    SHIELDS, MB
    ECHELMAN, DA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 747 - 747
  • [26] CAT MODEL FOR INTRAOCULAR-PRESSURE REDUCTION AFTER TRANSSCLERAL ND-YAG CYCLOPHOTOCOAGULATION
    ROSENBERG, LF
    BURCHFIELD, JC
    KRUPIN, T
    BOCK, CJ
    GOLDENFELD, M
    OGRADY, RB
    CURRENT EYE RESEARCH, 1995, 14 (04) : 255 - 261
  • [27] A TECHNIQUE FOR PRECISE PLACEMENT OF LASER APPLICATIONS IN TRANSSCLERAL ND - YAG CYCLOPHOTOCOAGULATION
    FIORE, PM
    LATINA, MA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (03) : 292 - 293
  • [28] THE EFFECT OF FLURBIPROFEN (FL) ON THE HISTOPATHOLOGY OF PIGMENTED RABBIT EYES AFTER CONTACT TRANSSCLERAL ND-YAG LASER CYCLOPHOTOCOAGULATION (CYC)
    FRIEDMAN, AH
    SCHMIDT, KG
    CAMRAS, CB
    PODOS, SM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 958 - 958
  • [29] INADVERTENT SCLEROSTOMY DURING TRANSSCLERAL ND-YAG CYCLOPHOTOCOAGULATION (VOL 118, PG 669, 1994)
    BEADLES, KA
    SMITH, MF
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (04) : 526 - 526
  • [30] Long term results of transscleral contact Nd:YAG laser cyclophotocoagulation.
    Collur, S
    Glavas, IP
    Heltzer, JM
    Schuman, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S279 - S279