A NEW CONCEPT IN FRACTURE IMMOBILIZATION - THE APPLICATION OF A PRESSURIZED BRACE

被引:0
|
作者
DALE, PA [1 ]
BRONK, JT [1 ]
OSULLIVAN, ME [1 ]
CHAO, EYS [1 ]
KELLY, PJ [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT ORTHOPED,200 1ST ST SW,ROCHESTER,MN 55905
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Sixteen dogs and 14 anatomic tibiae were studied to determine the effect of a pressurized brace on a canine tibial fracture model. Bilateral tibial fractures were treated with an external fixator for 48 days. At 48 days, the pressurized brace was applied to one tibia, and a conventional cast was applied to the opposite tibia. The dogs were allowed unrestricted weight bearing until 88 days. Postmortem biomechanical studies indicated that tibiae were stronger on the side treated by the pressurized brace. This was reflected in torque values, energy, and degrees of rotation. The histomorphometry of the periosteal bone of the fracture sites disclosed a more dense periosteal callus on the side treated with a pressurized brace. In vitro mechanical studies in cadaveric tibias at 30-degrees rotation indicated that the pressurized brace provided significantly more stability.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 50 条
  • [31] New concept of witness encryption and application
    Guo, Ren
    Chen, Fuji
    Cheng, Xiaogang
    Chen, Yonghong
    ICIC Express Letters, Part B: Applications, 2016, 7 (10): : 2183 - 2188
  • [32] Thermomechanical fracture on pressurized cylindrical vessels
    Tzou, DY
    Chiu, KS
    Beraun, JE
    Chen, JK
    HIGH-POWER LASER ABLATION, PTS 1-2, 1998, 3343 : 608 - 617
  • [33] ARGOS PHWR-380, A NEW CONCEPT OF A PRESSURIZED HEAVY-WATER REACTOR
    GONZALEZ, AJ
    FRISCHENGRUBER, K
    RECALDE, JA
    SOLANILLA, RB
    VANZULLI, RC
    KERNTECHNIK, 1988, 52 (02) : 91 - 95
  • [34] DYNAMIC FRACTURE LOADING IN A FEMORAL FRACTURE BRACE - A BIOMECHANICAL AND CLINICAL-STUDY
    PRATT, DJ
    BOWKER, P
    SCOTT, JM
    WARDLAW, D
    MCLAUCHLAN, J
    JOURNAL OF BIOMECHANICS, 1982, 15 (10) : 806 - 806
  • [35] MODIFIED FRACTURE BRACE FOR TIBIAL FRACTURE WITH VARUS ANGULATION - A CASE-REPORT
    TANG, SFT
    AU, TLS
    WONG, AMK
    LEE, MY
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1995, 19 (02) : 115 - 119
  • [36] PATIENT IMMOBILIZATION WITH A LOW-TEMPERATURE SPLINT-BRACE MATERIAL
    BARISH, RJ
    LERCH, IA
    RADIOLOGY, 1978, 127 (02) : 548 - 548
  • [37] RIGIDITY OF FRACTURE IMMOBILIZATION WITH PLATES
    LINDAHL, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1967, 38 (01): : 101 - &
  • [38] Immobilization with removable walking brace for treatment of chronic foot and ankle pain
    Crincoli, MG
    Trepman, E
    FOOT & ANKLE INTERNATIONAL, 2001, 22 (09) : 725 - 730
  • [39] Patients reject the concept of fragility fracture—a new understanding based on fracture patients’ communication
    J. E. M. Sale
    M. A. Gignac
    L. Frankel
    G. Hawker
    D. Beaton
    V. Elliot-Gibson
    E. Bogoch
    Osteoporosis International, 2012, 23 : 2829 - 2834
  • [40] Application of statically indeterminate fracture mechanics to evaluating structural integrity (application to axially cracked internally pressurized and spinning cylinders)
    Matsubara, Masaaki
    Soneda, Naoki
    Nippon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 1991, 57 (536): : 782 - 788