SAMPLE INTRODUCTION IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY USING SEQUENTIAL DENSITY GRADIENT FOCUSING AND SOLVENT VENTING

被引:7
|
作者
LIU, ZY [1 ]
FARNSWORTH, PB [1 ]
LEE, ML [1 ]
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
关键词
SOLVENT VENT; DENSITY GRADIENT FOCUSING; CAPILLARY COLUMNS; SUPERCRITICAL FLUID CHROMATOGRAPHY; SAMPLE INTRODUCTION;
D O I
10.1002/mcs.1220030508
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A technique was developed for large volume sample introduction in capillary supercritical fluid chromatography. A 20-cm length of 200-mu-m i.d. capillary tubing was used as precolumn. The precolumn temperature could be easily controlled by passing an electrical current through an electrically conductive paint coated on its outer surface. During injection, the sample solvent was vented from the precolumn with CO2 (gas) at 32 atm, while the precolumn was kept at room temperature. Solutes were transferred onto the head of the analytical column as a narrow band by density gradient focussing, which was established with (a) a temperature gradient along the precolumn, (b) a rapid expansion of CO2 from supercritical fluid to gas, and (c) a temperature difference between the precolumn and the analytical column. This injection approach minimized solute mass discrimination and could be easily performed.
引用
收藏
页码:435 / 442
页数:8
相关论文
共 50 条
  • [41] SUPERCRITICAL FLUID CHROMATOGRAPHY USING ULTRA-SMALL DIAMETER CAPILLARY COLUMNS
    MARKIDES, KE
    SUMPTER, SR
    WOOLLEY, CL
    HUANG, EC
    LEE, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 104 - ANYL
  • [42] DETERMINATION OF TOLUENE DIISOCYANATES IN POLYURETHANE PREPOLYMERS USING CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    RIDGEWAY, RG
    BANDY, AR
    QUAY, JR
    MAROULIS, PJ
    MICROCHEMICAL JOURNAL, 1990, 42 (01) : 138 - 145
  • [43] ANALYSIS OF CHEMICAL ADDITIVES IN POLYPROPYLENE FILMS USING CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    MOULDER, R
    KITHINJI, JP
    RAYNOR, MW
    BARTLE, KD
    CLIFFORD, AA
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1989, 12 (10): : 688 - 690
  • [44] Separation of perfluorinated polyethers using packed capillary column supercritical fluid chromatography
    Wu, NJ
    Shen, YF
    Lopez-Avila, V
    Lee, ML
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (04) : 287 - 297
  • [45] Gradient supercritical fluid chromatography coupled to mass spectrometry with a gradient flow of make-up solvent for enantioseparation of cathinones
    Kolderova, Natalie
    Jurasek, Bronislav
    Kuchar, Martin
    Lindner, Wolfgang
    Kohout, Michal
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1625 (1625)
  • [46] SPLITTING CONTROL AND SOLVENT EFFECTS IN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH FUSED-SILICA CAPILLARY COLUMNS
    BOHM, M
    UMLAND, F
    WENCLAWIAK, B
    JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01): : 17 - 21
  • [47] DETERMINATION OF THE HOLD-UP TIME AND COLUMN OUTLET DENSITY FOR CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    RIESTER, RL
    YAN, C
    MARTIRE, DE
    JOURNAL OF CHROMATOGRAPHY, 1991, 588 (1-2): : 289 - 294
  • [48] Finding the ideal solvent for the analysis of polar analytes using supercritical fluid chromatography
    Legelli, Mo
    Froning, Matti
    Wirtz, Michaela
    Lamotte, Stefan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (02) : 323 - 333
  • [49] DIRECT COUPLING OF CAPILLARY SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH SUPERCRITICAL-FLUID EXTRACTION USING MODIFIED CARBON-DIOXIDE
    DAIMON, H
    HIRATA, Y
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1994, 17 (12): : 809 - 813
  • [50] ANALYSIS OF PYRETHRINS USING CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY WITH FOURIER-TRANSFORM INFRARED DETECTION
    WIEBOLDT, RC
    KEMPFERT, KD
    LATER, DW
    CAMPBELL, ER
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1989, 12 (02): : 106 - 111