HPLC DETERMINATION OF A METOCLOPRAMIDE AND ONDANSETRON MIXTURE IN 0.9-PERCENT SODIUM-CHLORIDE INJECTION

被引:24
|
作者
VENKATESHWARAN, TG
KING, DT
STEWART, JT
机构
[1] Department of Medicinal Chemistry, College of Pharmacy, The University of Georgia, Athens, Georgia
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1995年 / 18卷 / 01期
关键词
D O I
10.1080/10826079508009225
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high performance liquid chromatography procedure has been developed for the assay of a metoclopramide and ondansetron mixture in 0.9% sodium chloride injection. The separation and quantitation are achieved on a base deactivated octylsilane column at ambient temperature using a mobile phase of 77:23 v/v 0.01 M phosphate buffer, pH 4 - acetonitrile at a flow rate of 1.0 mL/min with detection of analytes at 273 nm. The separation is achieved within 15-20 min with sensitivity in the ng/mL range for each analyte. The method showed linearity for metoclopramide and ondansetron in the 12.5 - 50 and 5-20 mu g/mL ranges, respectively. Accuracy and precision were in the 1 - 2% and 0.3 - 1.3% ranges, respectively, for both drugs. The limits of detection for metoclopramide and ondansetron were 49 and 20 ng/mL, respectively, based on a signal to noise ratio of 3 and a 20 mu L injection.