FLUORESCENCE ASSAY OF GLUCOSYLCERAMIDE GLUCOSIDASE USING NBD-CEREBROSIDE

被引:3
|
作者
ABE, A
SHAYMAN, JA
RADIN, NS
机构
[1] UNIV MICHIGAN,MED CTR,DEPT OBSTET & GYNECOL,DIV NEPHROL,1150 W MED CTR DR,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,MENTAL HLTH RES INST,ANN ARBOR,MI 48109
关键词
D O I
10.1007/BF02535587
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive fluorometric assay for glucocerebroside beta-glucosidase [Dinur, T., Grabowski, G.A., Desnick, R.J., and Gatt, S. (1984) AnaL Biochem. 136,223-2341 has been reexamined. It was found that the lipids containing the NBD moiety (12-[N-methyl-N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)] used for standardization of the assay are light-sensitive and that the yield of fluorescent light is very sensitive to the composition of the solvent used in the fluorometric measurement. Some protection against fading could be obtained by adding a free-radical trapping agent, SlowFade. The fading of the free NBD-acid, when used for standardization, could be prevented by adding ethanol to the solvent, but this reduced the fluorescence yield. It is recommended that some of the fluorescent substrate be enzymatically hydrolyzed completely to NBD-ceramide, which can be utilized as the standard without the need to add ethanol. A warning about enzyme reaction rate stability with time is given, with a suggestion for ensuring constancy of activity.
引用
收藏
页码:1052 / 1054
页数:3
相关论文
共 50 条
  • [31] A high-throughput biliverdin assay using infrared fluorescence
    Berlec, Ales
    Strukelj, Borut
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (04) : 521 - 526
  • [32] Fluorescence Assay for Phospholipase C Activity Using Liposome Probes
    Gu Qiao-Rong
    Ai Jun-Jie
    Zhang Qian-Yun
    Dong Ya-Nan
    Gao Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (09) : 1278 - 1283
  • [33] Assay of flurbiprofen in rat plasma using HPLC with fluorescence detection
    Park, KM
    Gao, ZG
    Kim, CK
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (12) : 1849 - 1855
  • [34] ASSAY OF NEUROACTIVE PREGNANE STEROIDS USING HPLC WITH FLUORESCENCE DETECTION
    HOGENKAMP, DJ
    BOLGER, MB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 113 - MEDI
  • [35] A NOVEL CYTOTOXICITY SCREENING ASSAY USING A MULTIWELL FLUORESCENCE SCANNER
    NIEMINEN, AL
    GORES, GJ
    BOND, JM
    IMBERTI, R
    HERMAN, B
    LEMASTERS, JJ
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 1992, 115 (02) : 147 - 155
  • [36] Novel fluorescence enhancement IgE assay using a DNA aptamer
    He, Jing-Lin
    Wu, Zai-Sheng
    Zhang, Song-Bai
    Shen, Guo-Li
    Yu, Ru-Qin
    ANALYST, 2009, 134 (05) : 1003 - 1007
  • [37] New fragile X repeat assay using fluorescence ratios
    Adler, Karl
    Moore, Kent
    Filippov, Galina
    Schermer, Mack
    CHROMOSOME RESEARCH, 2011, 19 : S89 - S89
  • [38] Sterol binding assay using surface plasmon fluorescence spectroscopy
    Wiltschi, B
    Schober, M
    Kohlwein, SD
    Oesterhelt, D
    Sinner, EK
    ANALYTICAL CHEMISTRY, 2006, 78 (02) : 547 - 555
  • [39] A novel method for the assay of α-glucosidase inhibitory activity using a multi-channel oxygen sensor
    Matsumoto, K
    Takemata, K
    Takayama, K
    Abesundara, KJM
    Matsui, T
    Katayama, H
    ANALYTICAL SCIENCES, 2002, 18 (12) : 1315 - 1319
  • [40] A Novel Method for the Assay of α-Glucosidase Inhibitory Activity Using a Multi-channel Oxygen Sensor
    Kiyoshi Matsumoto
    Kayoko Takemata
    Kiyofumi Takayama
    Kanthi J. M. Abesundara
    Toshiro Matsui
    Hideo Katayama
    Analytical Sciences, 2002, 18 : 1315 - 1319