COMPARISON OF DIFCO ESP AND ORGANON-TEKNIKA BACT/ALERT CONTINUOUS-MONITORING BLOOD CULTURE SYSTEMS

被引:25
|
作者
ZWADYK, P
PIERSON, CL
YOUNG, C
机构
[1] DUKE UNIV,DEPT PATHOL,DURHAM,NC 27710
[2] UNIV MICHIGAN,DEPT PATHOL,ANN ARBOR,MI 48109
关键词
D O I
10.1128/JCM.32.5.1273-1279.1994
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Difco ESP and Organon Teknika BacT/Alert (BTA) systems were evaluated in a clinical study of 5,421 aerobic and 5,035 anaerobic blood cultures. Of 405 clinically significant positive cultures evaluated, 272 grew in both systems, 86 grew in ESP only, and 47 grew in BTA only (P < 0.005). Of 320 organisms detected in aerobic bottles, 208 grew in both systems, 68 grew in ESP only and 45 grew in BTA only (P < 0.05), with Staphylococcus aureus the only organism showing a statistically significant difference. The ESP anaerobic bottle also detected more anaerobes (16 of 17 versus 4 of 17, P < 0.005) and more organisms overall (57 versus 34, P < 0.05). How ever, with the exception of patients with anaerobic bacteremia (12 of 13 for ESP and 4 of 13 for BTA, P < 0.05), there was no statistical difference in the detection of patient episodes. Average detection time of matched aerobic bottles was 18.3 h for ESP and 22.0 h for BTA (P < 0.001). For matched pairs of anaerobic bottles, the average detection time was faster in the BTA bottles (P < 0.001), because of the growth of facultative organisms. To explore the differences in anaerobic detection more fully, 20 sets of anaerobic bottles were seeded with 12 anaerobic species mixed with human blood. ESP grew more organisms (17 of 20 versus 10 of 20, P < 0.025), and the average time to detection for the 10 paired positive cultures was 21.6 h for ESP and 50.8 h for BTA (P < 0.05). Times for loading and unloading bottles were similar for both systems.
引用
收藏
页码:1273 / 1279
页数:7
相关论文
共 50 条
  • [21] Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates
    Riedel, Stefan
    Siwek, Gregory
    Beekmann, Susan E.
    Richter, Sandra S.
    Raife, Thomas
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2262 - 2264
  • [22] Comparison of BACTEC 9240 and BacT/Alert Blood Culture Systems for Detection of Microbiological Contamination in Platelet Concentrates
    Givisiez, F. N.
    Cioffi, J. M.
    Basques, F. V.
    Santos, V. A.
    Rezende, G. C.
    Silva, R. M.
    Ferreira, A. M.
    Paiva, L. F.
    Oliveira, L. T.
    Tardelli, A. C.
    TRANSFUSION, 2014, 54 : 206A - 206A
  • [23] Use of simulated blood cultures for time to detection comparison between BacT/ALERT™ and BACTEC™ 9240 blood culture systems
    FrancescoViganò, E
    Vasconi, E
    Agrappi, C
    Clerici, P
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 44 (03) : 235 - 240
  • [24] Clinical comparison of the Bactec Mycosis IC/F, BacT/Alert FA, and BacT/Alert FN blood culture vials for the detection of candidemia
    Ericson, Eva-Lena
    Klingspor, Lena
    Ullberg, Mans
    Ozenci, Volkan
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 73 (02) : 153 - 156
  • [25] Comparison of BacT/Alert blood culture bottles with lytic media for culture of peritoneal dialysis fluid
    Wust, J
    vonGraevenitz, A
    INFECTION, 1995, 23 (06) : 378 - 379
  • [26] Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples
    Congestri, Francesco
    Pedna, Maria Federica
    Fantini, Michela
    Samuelli, Michela
    Schiavone, Pasqua
    Torri, Arianna
    Bertini, Stefania
    Sambri, Vittorio
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2017, 62 : 1 - 5
  • [27] Quality indicators for blood culture: 1 year of monitoring with BacT/Alert Virtuo at a French hospital
    Emeraud, Cecile
    Yilmaz, Seher
    Fortineau, Nicolas
    Cuzon, Gablle
    Dortet, Laurent
    JOURNAL OF MEDICAL MICROBIOLOGY, 2021, 70 (03)
  • [28] MICROBIOLOGICAL DIAGNOSIS IN CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS (CAPD) - COMPARISON OF BACTEC AND BACT/ALERT BLOOD CULTURING SYSTEMS
    UTIEL, FJB
    BANASCO, VP
    LENDINEZ, IC
    CARAZO, CC
    PERALES, CS
    CORTES, MJG
    DELBARRIO, PP
    CANADA, AL
    KIDNEY INTERNATIONAL, 1995, 48 (01) : 292 - 292
  • [29] Continuous-monitoring blood culture screening system improves the detection of bacteremia in neutropenic patients
    Kinnunen, U
    Syrjala, H
    Koskela, M
    Kujala, P
    Koistinen, P
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 1996, 28 (03) : 287 - 292
  • [30] Comparative evaluation of BACTEC FX, BacT/ALERT 3D, and BacT/ALERT VIRTUO-automated blood culture systems using simulated blood cultures
    Li, Zhengkang
    Liu, Suling
    Chen, Huimin
    Zhang, Xinqiang
    Ling, Yong
    Zhang, Ni
    Hou, Tieying
    ACTA CLINICA BELGICA, 2022, 77 (01) : 71 - 78