10 YEARS OF EXPERIENCE WITH LEAK DETECTION BY ACOUSTIC-SIGNAL ANALYSIS

被引:222
|
作者
FUCHS, HV
RIEHLE, R
机构
[1] Fraunhofer-Institut fur Bauphysik (IBP) Director: o. Prof. Dr.-Ing. habil. Dr. h. c. Karl A. Gertis., Stuttgart
[2] Ingenieurgesellschaft für angewandte Sensortechnik (FAST), Langenbrettach
关键词
D O I
10.1016/0003-682X(91)90062-J
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Leaks in pipelines cause unnecessary waste of scarce resources and often endanger the environment. The Fraunhofer-Institut fur Bauphysik (IBP), therefore, together with Technische Werke der Stadt Stuttgart (TWS), have developed and tested an effective acoustical technique of leak detection by correlation analysis (LOKAL). In the meantime several mobile measurement units for systematic checks of water supply systems have been established, and a compact electronic device has been developed and recently put on the market by Ingenieurgesellschaft fur angewandte Sensortechnik (FAST). Ten years of experience with systematic surveys of water supply networks have shown that the specific losses can be reduced, on average, from approximately 1000 to less than 500 m3/km per year. The new technique thus opens new possibilities of conserving precious water resources.