NOISE REMOVAL IN MONITORING SENSORS OF CIVIL STRUCTURES USING BLIND SOURCE SEPARATION

被引:0
|
作者
Santos, Daniel Moraes [1 ]
Paschoarelli Veiga, Antonio Claudio [1 ]
机构
[1] Univ Fed Uberlandia, Dept Elect Engn, Av Joao Naves Avila 2121, Uberlandia, MG, Brazil
关键词
Blind source separation; Statistical analysis; Sensors; Independent component analysis; Noise; Temporal predictability; Maximum signal noise ratio;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Blind source separation (BSS) is known to be an efficient and powerful process to separate and estimate individual mutually independent signals acquired by various types of monitoring sensors. This paper proposes an algorithm to identify and reduce noise in monitoring sensor signals using blind source separation. This algorithm can be applied in any area of monitoring. It can identify noise without any kind of previous information of the signal analyzed. Initially, the algorithm makes the separation of the signals that were acquired by the sensors. These signals may have suffered influence from several noise sources. Different from the standard BSS, which requires at least two sources, this algorithm removes the noise from each signal separately applying the maximum signal-to-noise ratio and temporal predictability algorithms. The proposed algorithm also produces two outputs for each signal, the estimated original signal and the estimated noise. The results satisfy all the proposed objectives of this work. The proposed algorithm is a great solution for other types of applications, such as thermal profiling of wells.
引用
收藏
页码:1989 / 2009
页数:21
相关论文
共 50 条
  • [31] Multiple Damage Detection using Sparse Blind Source Separation in Composite Structures
    Dong, Shaopeng
    Yuan, Mei
    Shang, Fukai
    Liang, Yuxuan
    Jiao, Zongxia
    PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON FLUID POWER AND MECHATRONICS - FPM 2015, 2015, : 1285 - 1290
  • [32] Fiber optic health monitoring of civil structures using long gage and acoustic sensors
    Ansari, F
    SMART MATERIALS & STRUCTURES, 2005, 14 (03): : S1 - S7
  • [33] Condition monitoring of the strength and stability of civil structures using thick film ceramic sensors
    Jabir, Saad A. A.
    Gupta, Naren K.
    MEASUREMENT, 2013, 46 (07) : 2223 - 2231
  • [34] Underdetermined Blind Source Separation Based Condition Monitoring
    Vinaya, Anindita Adikaputri
    Arifianto, Dhany
    2015 INTERNATIONAL CONFERENCE ON SCIENCE IN INFORMATION TECHNOLOGY (ICSITECH), 2015, : 47 - 52
  • [35] New efficient subband structures for blind source separation
    Batalheiro, Paulo B.
    Petraglia, Mariane R.
    Haddad, Diego B.
    SIGNAL PROCESSING, 2021, 182
  • [36] Distributed Optical Fiber Sensors for Monitoring of Civil Engineering Structures
    Kishida, Kinzo
    Imai, Michio
    Kawabata, Junichi
    Guzik, Artur
    SENSORS, 2022, 22 (12)
  • [37] Development of the distributed brillouin sensors for health monitoring of civil structures
    Bao, Xiaoyi
    Chen, Liang
    OPTICAL WAVEGUIDE SENSING AND IMAGING, 2008, : 101 - 125
  • [38] A robust algorithm for convolutive blind source separation in presence of noise
    El Rhabi, M.
    Fenniri, H.
    Keziou, A.
    Moreau, E.
    SIGNAL PROCESSING, 2013, 93 (04) : 818 - 827
  • [39] A novel underdetermined blind source separation method with noise and unknown source number
    Lu, Jiantao
    Cheng, Wei
    He, Dong
    Zi, Yanyang
    JOURNAL OF SOUND AND VIBRATION, 2019, 457 : 67 - 91
  • [40] Analysis of Blind Source Separation Techniques for Eye Artifact Removal
    Aspiras, Theus H.
    Asari, Vijayan K.
    WIRELESS NETWORKS AND COMPUTATIONAL INTELLIGENCE, ICIP 2012, 2012, 292 : 340 - 349