Tracheal Rupture due to Diffusion of Nitrous Oxide to Cuff of High-Volume, Low-Pressure Intubation Tube

被引:0
|
作者
Atalay, Canan [1 ]
Aykan, Seyda [1 ]
Can, Abdullah [1 ]
Dogan, Nazim [1 ]
机构
[1] Ataturk Univ, Fac Med, Dept Anesthesiol & Reanimat, TR-25070 Erzurum, Turkey
来源
EURASIAN JOURNAL OF MEDICINE | 2009年 / 41卷 / 02期
关键词
Tracheal rupture; High-volume; low-pressure endotracheal tube; Nitrous oxide;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tracheal rupture is a rare complication of endotracheal intubation. Risk factors include short neck, repeated attempts due to failed intubation, inappropriate stylus, over-inflation of the cuff, poor positioning of the tube, inappropriate tube size, weakened membrane structure due to steroid use, chronic obstructive pulmonary disease, tracheomalacia, kyphosis, and use of nitric oxide during the operation. In this article, we suggest that high-volume, low-pressure tubes may not always provide a low-pressure effect and could rupture due to reduced tracheal perfusion pressure and ischemic damage upon over-inflation.
引用
收藏
页码:136 / 139
页数:4
相关论文
共 50 条
  • [31] THE EFFECT OF NITROUS-OXIDE CONCENTRATION ON TRACHEAL TUBE CUFF PRESSURE INCREASES DURING GENERAL-ANESTHESIA
    SOSIS, WB
    BLAZEK, W
    ANESTHESIOLOGY, 1994, 81 (3A) : A497 - A497
  • [32] Profile Soft-Seal Cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide
    Karasawa, F
    Mori, T
    Okuda, T
    Satoh, T
    ANESTHESIA AND ANALGESIA, 2001, 92 (01): : 140 - 144
  • [33] NITROUS-OXIDE AND PRESSURES AND VOLUMES OF HIGH-PRESSURE AND LOW-PRESSURE ENDOTRACHEAL-TUBE CUFFS IN INTUBATED PATIENTS
    STANLEY, TH
    ANESTHESIOLOGY, 1975, 42 (05) : 637 - 640
  • [34] TRACHEAL TUBE CUFF PRESSURE - CHANGES DURING NITROUS-OXIDE ANESTHESIA FOLLOWING INFLATION OF CUFFS WITH AIR AND SALINE
    PATEL, RI
    OH, TH
    CHANDRA, R
    EPSTEIN, BS
    ANAESTHESIA, 1984, 39 (09) : 862 - 864
  • [35] Evaluation of pressure changes in a new design tracheal tube cuff, the Porter Soft Seal, during nitrous oxide anaesthesia
    Al-Shaikh, B
    Jones, M
    Baldwin, F
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 83 (05) : 805 - 806
  • [36] A HIGH-VOLUME SPRAY AEROSOL GENERATOR PRODUCING SMALL DROPLETS FOR LOW-PRESSURE APPLICATIONS
    KANG, YC
    PARK, SB
    JOURNAL OF AEROSOL SCIENCE, 1995, 26 (07) : 1131 - 1138
  • [37] Tracheal ulcer development from high volume, low-pressure cuffed endotracheal tubes
    Malkoc, Aldin
    Wong, Stephanie
    Gnanadev, Raja
    Phan, Alexander
    Farrokhi, Haley
    Nguyen, Danny T.
    Wong, David T.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2024, 45 (01)
  • [38] CLINICAL EXPERIENCE WITH NEW LOW-PRESSURE HIGH-VOLUME TRACHEOSTOMY CUFFS - IMPORTANCE OF LIMITING INTRACUFF PRESSURE
    CHING, NPH
    NEALON, TF
    NEW YORK STATE JOURNAL OF MEDICINE, 1974, 74 (13) : 2379 - 2384
  • [39] Fastrach uses a low-volume, high-pressure cuff for the endotracheal tube system
    Wiesel, S
    Warm, T
    ANESTHESIOLOGY, 1999, 91 (02) : 592 - 593
  • [40] Comparison of air-sealing characteristics of tapered- vs. cylindrical-shaped high-volume, low-pressure tube cuffs
    Madjdpour, C.
    Mauch, J.
    Dave, M. H.
    Spielmann, N.
    Weiss, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2012, 56 (02) : 230 - 235