VIRTUAL SIMULATION - INITIAL CLINICAL-RESULTS

被引:31
|
作者
ROSENMAN, J [1 ]
SAILER, SL [1 ]
SHEROUSE, GW [1 ]
CHANEY, EL [1 ]
TEPPER, JE [1 ]
机构
[1] UNIV N CAROLINA, CHAPEL HILL, NC 27514 USA
关键词
TREATMENT PLANNING; COMPUTER GRAPHICS; 3D DISPLAYS;
D O I
10.1016/0360-3016(91)90032-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have developed a graphics-based three-dimensional treatment design system that permits the physician to easily understand which anatomy will be treated for any arbitrary beam orientation. Our implementation of this system differs from others in that the software (the Virtual Simulator) simulates the full functionality of a (physical) radiation therapy simulator allowing it to be easily used by physicians. The details of the of our initial clinical experience with virtual simulation are presented in this paper. Virtual simulation was attempted in 71 patients and completed in 65. In 41/71 patients (58%), the beam orientations chosen differed significantly from those traditionally used in our department. Although virtual simulation lead to traditional radiation portals in the remaining patients, in 23/71 (32%) secondary blocking was designed which was different from that which would have been conventionally employed. Thus, overall, virtual simulation lead to treatment changes in 64/71 (90%) of the patients in whom it was attempted. In 78% of evaluable patients the treatment designed with virtual simulation could be implemented on the physical simulator with a precision of +/- 5 mm (+/- 3 mm for brain and head and neck). Thus virtual simulation allowed both accurate planning and execution of treatment plans that would be difficult to achieve with conventional methods.
引用
收藏
页码:843 / 851
页数:9
相关论文
共 50 条
  • [41] TRIMETREXATE - OVERALL CLINICAL-RESULTS
    BERTINO, JR
    SEMINARS IN ONCOLOGY, 1988, 15 (02) : 50 - 51
  • [42] KERATOPHAKIA AND KERATOMILEUSIS - CLINICAL-RESULTS
    SWINGER, CA
    BARRAQUER, JI
    OPHTHALMOLOGY, 1981, 88 (08) : 709 - 715
  • [43] CLINICAL-RESULTS WITH THE CLEON SCANNER
    ELL, PJ
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (628): : 386 - 386
  • [44] EVALUATION OF FUNCTIONAL POSITIONS OF TONGUE AND SOFT PALATE WITH MR IMAGING - INITIAL CLINICAL-RESULTS
    WEIN, BB
    DROBNITZKY, M
    KLAJMAN, S
    ANGERSTEIN, W
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03): : 381 - 383
  • [45] INITIAL CLINICAL-RESULTS OF A 430 MHZ MICROWAVE HYPERTHERMIA SYSTEM USING A LENS APPLICATOR
    NISHIMURA, Y
    AKUTA, K
    HIRAOKA, M
    MASUNAGA, S
    NAGATA, Y
    TAKAHASHI, M
    ABE, M
    KOIZUMI, K
    RADIOTHERAPY AND ONCOLOGY, 1990, 17 (03) : 219 - 227
  • [46] PERCUTANEOUS PERIPHERAL LASER ANGIOPLASTY BY A NOVEL BARE FIBER CATHETER - INITIAL CLINICAL-RESULTS
    HEINTZEN, MP
    NEUBAUR, T
    KLEPZIG, M
    ZEITLER, E
    STRAUER, BE
    CIRCULATION, 1987, 76 (04) : 231 - 231
  • [47] MRI OF TRIGEMINAL NEURALGIA - INITIAL CLINICAL-RESULTS IN PATIENTS WITH VASCULAR COMPRESSION OF THE TRIGEMINAL NERVE
    SENS, MAA
    HIGER, HP
    NEUROSURGICAL REVIEW, 1991, 14 (01) : 69 - 73
  • [48] PERCUTANEOUS ROTATIONAL CONTACT BILIARY LITHOTRIPSY - INITIAL CLINICAL-RESULTS WITH THE KENSEY NASH LITHOTRITE
    MILLER, FJ
    ROSE, SC
    BUCHI, KN
    HUNTER, JG
    NASH, JE
    KENSEY, KR
    RADIOLOGY, 1991, 178 (03) : 781 - 785
  • [49] THE SAFETY OF SIMULTANEOUS ARTERIAL AND CORONARY SINUS PERFUSION - EXPERIMENTAL BACKGROUND AND INITIAL CLINICAL-RESULTS
    IHNKEN, K
    MORITA, K
    BUCKBERG, GD
    AHARON, A
    LAKS, H
    PANOS, AL
    DRINKWATER, DC
    CHUGH, R
    DELRIZZO, D
    SALERNO, TA
    JOURNAL OF CARDIAC SURGERY, 1994, 9 (01) : 15 - 25
  • [50] INITIAL CLINICAL-RESULTS WITH THE WIKTOR STENT - A NEW BALLOON-EXPANDABLE CORONARY STENT
    BUCHWALD, A
    UNTERBERG, C
    WERNER, G
    VOTH, E
    KREUZER, H
    WIEGAND, V
    CLINICAL CARDIOLOGY, 1991, 14 (05) : 374 - 379