THERMOLUMINESCENT RESPONSE OF (LIF)-LI-6 (MG,CU,P) AND (LIF)-LI-7 (MG,CU,P) TL CHIPS IN NEUTRON AND GAMMA-RAY MIXED RADIATION-FIELDS

被引:0
|
作者
WANG, SS
CAI, GG
ZHOU, KQ
ZHOU, RX
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
引用
收藏
页码:247 / 250
页数:4
相关论文
共 50 条
  • [41] Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosemeter to photons
    Konnai, Akiko
    Nariyama, Nobuteru
    Ohnishi, Seiki
    Odano, Naoteru
    Ozasa, Naoto
    Ishikawa, Yuhzoh
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 125 - 128
  • [42] Measurements and Monte Carlo simulations of the response of the RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) thermoluminescent detectors to X- and gamma-rays
    Obryk, B.
    Cywicka-Jakiel, T.
    Budzanowski, M.
    Bilski, P.
    Hranitzky, C.
    Olko, P.
    Stadtmann, H.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 616 - 620
  • [44] Effect of neutron irradiation on dosimetric properties of TLD-600H (6LiF:Mg,Cu,P)
    Romanyukha, A.
    Minniti, R.
    Moscovitch, M.
    Thompson, A. K.
    Trompier, F.
    Colle, R.
    Sucheta, A.
    Voss, S. P.
    Benevides, L. A.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1426 - 1431
  • [45] Extremity and whole-body dosemeters for beta and beta gamma fields based on LiF:Mg,Cu,P thin detectors
    Pérez, S
    Ginjaume, M
    Ortega, X
    Duch, MA
    Roig, M
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 261 - 266
  • [46] Extremity and whole-body dosemeters for beta and beta gamma fields based on LiF:Mg,Cu,P thin detectors
    Pérez, S
    Ginjaume, M
    Ortega, X
    Duch, MA
    Roig, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A261 - A266
  • [47] THE ENVIRONMENTAL MONITORING OF THE NATURAL RADIATION BACKGROUND IN ANTARCTICA WITH LIF-MG,CU,P TLD AND X-GAMMA RADIOMETRY
    CAI, G
    GENG, K
    WANG, Q
    RADIATION PROTECTION DOSIMETRY, 1995, 60 (03) : 259 - 262
  • [48] Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV
    Cai, GG
    Bestion, N
    Wang, SS
    Shen, WX
    Delard, R
    Volpiliere, J
    Fesquet, J
    Gasiot, J
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 213 - 215
  • [49] Thermoluminescent response of LiF: Mg,Cu,P+PTFE prepared in Mexico to 90Sr/90Y beta particles
    González, PR
    Azorín, J
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 425 - 427
  • [50] Estimation of ambient dose equivalent from environmental radiation using a 7LiF:Mg,Cu,P thermoluminescence dosemeter
    Cherestes, C.
    Cherestes, M.
    Constantinescu, L. M.
    Paraschiva, M. V.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (11): : 1159 - 1161