PLASMA TAURINE CONCENTRATIONS AND M-MODE ECHOCARDIOGRAPHIC MEASURES IN HEALTHY CATS AND IN CATS WITH DILATED CARDIOMYOPATHY

被引:58
|
作者
SISSON, DD
KNIGHT, DH
HELINSKI, C
FOX, PR
BOND, BR
HARPSTER, NK
MOISE, NS
KAPLAN, PM
BONAGURA, JD
CZARNECKI, G
SCHAEFFER, DJ
机构
[1] Department of Animal Science, University of Illinois
[2] Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania
[3] Department of Veterinary Clinical Medicine and Surgery, Nys College of Veterinary Medicine
[4] Department of Medicine, School of Veterinary Medicine, Tufts University
[5] Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University
关键词
D O I
10.1111/j.1939-1676.1991.tb00954.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
M-mode echocardiography was completed and plasma taurine concentrations were determined in 79 healthy cats and 77 cats with dilated cardiomyopathy (DCM). In healthy cats, a relationship was not observed between plasma taurine concentrations and any M-mode echocardiographic measurement. End-systolic and end-diastolic cardiac chamber dimensions were larger; wall thickness measures were smaller; and calculations of fractional shortening were less in cats with DCM than in healthy cats. Plasma taurine concentrations < 30 nmol/mL were detected in 7/79 healthy cats and in 52/77 cats with DCM. Of the 52 cats with DCM and an initial plasma taurine concentration < 30 nmol/mL, 23 died or were euthanized during the first post-treatment week, 7 were lost to further study, and 22 improved after taurine supplementation. Of the 25 cats with DCM and an initial plasma taurine concentration greater-than-or-equal-to 30 nmol/mL, 9 died or were euthanatized during the first post-treatment week, and 9 were lost to further study. Two cats did not improve, of which one died and one was euthanatized 4 to 8 weeks after initiation of taurine supplementation. Five cats with a plasma taurine concentration greater-than-or-equal-to 30 nmol/mL improved after taurine supplementation. Myocardial function subsequently deteriorated in three of these cats. Two of the three cats had signs of congestive heart failure redevelop.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [41] Plasma amino acid and whole blood taurine concentrations in cats eating commercially prepared diets
    Heinze, Cailin R.
    Larsen, Jennifer A.
    Kass, Philip H.
    Fascetti, Andrea J.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2009, 70 (11) : 1374 - 1382
  • [42] Variability of M-Mode Versus Two-Dimensional Echocardiography Measurements in Children With Dilated Cardiomyopathy
    Lee, Caroline K.
    Margossian, Renee
    Sleeper, Lynn A.
    Canter, Charles E.
    Chen, Shan
    Tani, Lloyd Y.
    Shirali, Girish
    Szwast, Anita
    Tierney, Elif Seda Selamet
    Campbell, M. Jay
    Golding, Fraser
    Wang, Yanli
    Altmann, Karen
    Colan, Steven D.
    PEDIATRIC CARDIOLOGY, 2014, 35 (04) : 658 - 667
  • [43] EVALUATION OF LEFT-VENTRICULAR FILLING IN DILATED CARDIOMYOPATHY USING DIGITIZED M-MODE ECHOCARDIOGRAMS
    RAHKO, PS
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1991, 8 (02): : 163 - 172
  • [44] Variability of M-Mode Versus Two-Dimensional Echocardiography Measurements in Children With Dilated Cardiomyopathy
    Caroline K. Lee
    Renee Margossian
    Lynn A. Sleeper
    Charles E. Canter
    Shan Chen
    Lloyd Y. Tani
    Girish Shirali
    Anita Szwast
    Elif Seda Selamet Tierney
    M. Jay Campbell
    Fraser Golding
    Yanli Wang
    Karen Altmann
    Steven D. Colan
    Pediatric Cardiology, 2014, 35 : 658 - 667
  • [45] INHERITANCE OF HYPERTROPHIC CARDIOMYOPATHY - A CROSS-SECTIONAL AND M-MODE ECHOCARDIOGRAPHIC STUDY OF 50 FAMILIES
    GREAVES, SC
    ROCHE, AHG
    NEUTZE, JM
    WHITLOCK, RML
    VEALE, AMO
    BRITISH HEART JOURNAL, 1987, 58 (03): : 259 - 266
  • [46] Plasma homocysteine, B vitamins, and amino acid concentrations in cats with cardiomyopathy and arterial thromboembolism
    McMichael, MA
    Freeman, LM
    Selhub, J
    Rozanski, EA
    Brown, DJ
    Nadeau, MR
    Rush, JE
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2000, 14 (05) : 507 - 512
  • [47] Two-dimensional and M-mode echocardiographic measurements of cardiac dimensions in healthy standardbred trotters
    Bakos, Z
    Vörös, K
    Järvinen, T
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2002, 50 (03) : 273 - 282
  • [48] Two-dimensional and M-mode echocardiographic reference values in healthy adult Saanen goats
    Leroux, A. A.
    Moonen, M. L.
    Farnir, F.
    Sandersen, C. F.
    Deleuze, S.
    Salciccia, A.
    Amory, H.
    VETERINARY RECORD, 2012, 170 (06) : 154 - U63
  • [49] M-MODE ECHOCARDIOGRAPHIC STUDY IN HEALTHY-MEN BORN AND LIVING AT HIGH-ALTITUDE
    CARRILLO, AP
    BRYCE, A
    AMATYLEON, F
    MONGE, C
    ROITMAN, M
    DELRIO, C
    SOTO, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (02) : 592 - 592
  • [50] FEEDING DIETS THAT LOWER PLASMA TAURINE (TAU) CONCENTRATIONS CAUSES REDUCED MYOCARDIAL MECHANICAL FUNCTION IN CATS
    PION, PD
    STURMAN, JA
    ROGERS, QR
    KITTLESON, MD
    HAYES, KC
    MORRIS, JG
    FASEB JOURNAL, 1988, 2 (06): : A1617 - A1617