RESULTS OF THE INTERNATIONAL STUDY OF THE IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - A COMPARISON OF EPICARDIAL AND ENDOCARDIAL LEAD SYSTEMS

被引:177
|
作者
ZIPES, DP
ROBERTS, D
机构
[1] Department of Medicine, Indiana Univ. School of Medicine, Krannert Institute of Cardiology, Indianapolis, IN
[2] Krannert Institute of Cardiology, Indianapolis, IN 46202-4800
关键词
DEFIBRILLATION; DEATH; SUDDEN; MORTALITY PACEMAKERS;
D O I
10.1161/01.CIR.92.1.59
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The purpose of the present report was to document clinical experience derived from the implantation of 2834 epicardial and endocardial cardioverter-defibrillators (ICDs) in 2807 patients who were followed for almost I year and to compare he results obtained with the two systems. Methods and Results Patients in the two groups had similar clinical characteristics. More than half of the patients had a total of almost 50 000 spontaneous ventricular tachyarrhythmias that were terminated with equal success (approximate to 98%) by epicardial and endocardial ICDs. Lead dislodgement and pocket infection occurred more often with the endocardial than with the epicardial ICD, whereas perioperative mortality was higher with the epicardial ICD than with the endocardial ICD. Mortality from sudden cardiac death was 1.4% in the epicardial ICD group and 0.6% in the endocardial ICD group at 1 year (P=.069). Overall mortality at 1 year was 12.2% and 6.9% for the epicardial and endocardial groups, respectively (P<.001), reflecting the higher surgical mortality for the epicardial system. Conclusions The endocardial ICD is as effective as the epicardial ICD but incurs lower perioperative mortality.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [21] Lead and generator dysfunction in children and adolescents with epicardial pacemaker and implantable cardioverter defibrillator systems: The challenge of early recognition
    Winkler, Florian
    von Felten, Stefanie
    Gass, Matthias
    Berger, Florian
    Balmer, R.
    Dave, Hitendu
    Balmer, Christian
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (02): : 321 - 329
  • [22] Lead and device dysfunction in children and adolescents with epicardial pacemaker and implantable cardioverter defibrillator systems: The challenge of early recognition
    Winkler, Florian
    von Felten, Stefanie
    Weber, Roland
    Gass, Matthias
    Berger, Florian
    Balmer, Christian
    SWISS MEDICAL WEEKLY, 2023, 153 : 44S - 44S
  • [23] THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-RESULTS
    PALATIANOS, GM
    THURER, RJ
    COOPER, DK
    GEORGAKAKIS, GE
    TUCKER, RL
    FERNANDEZ, P
    INTERIAN, A
    MYERBURG, RJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02): : 297 - 301
  • [24] INTRAATRIAL CONDUCTION DELAY ASSOCIATED WITH AN EPICARDIAL IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    KOCHERIL, AG
    BATSFORD, WP
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 26 (04) : 341 - 345
  • [25] Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections
    Sohail, Muhammad R.
    Uslan, Daniel Z.
    Khan, Akbar H.
    Friedman, Paul A.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Stoner, Sarah
    Baddour, Larry M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (18) : 1851 - 1859
  • [26] SUPERIORITY OF ENDOCARDIAL VERSUS EPICARDIAL IMPLANTATION OF THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD)
    SAGGAU, W
    SACK, FU
    LANGE, R
    WERLING, C
    DESIMONE, R
    BRACHMANN, J
    HAGL, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (04) : 195 - 200
  • [27] METHODS OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - PACEMAKER INSERTION TO AVOID INTERACTIONS
    SPOTNITZ, HM
    OTT, GY
    BIGGER, JT
    STEINBERG, JS
    LIVELLI, F
    ANNALS OF THORACIC SURGERY, 1992, 53 (02): : 253 - 257
  • [28] ARRHYTHMIAS AFTER CARDIOVERTER-DEFIBRILLATOR IMPLANTATION - COMPARISON OF EPICARDIAL AND TRANSVENOUS SYSTEMS
    ONG, JJC
    HSU, PC
    LIN, L
    YU, A
    KASS, RM
    PETER, T
    SWERDLOW, CD
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (02): : 137 - 140
  • [29] Automated Implantable Cardioverter Defibrillator/Pacemaker Lead Fracture
    Rubero, Lose
    Ramlatchan, Sidhartha R.
    Solomon, Matthew
    George, Andrew
    Ganti, Latha
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)
  • [30] INFECTIVE ENDOCARDITIS OF THE TRANSVENOUS LEAD OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    WERNER, GS
    GONSKA, BD
    HERSE, B
    KREUZER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (01): : 51 - 54