RESULTS OF THE INTERNATIONAL STUDY OF THE IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - A COMPARISON OF EPICARDIAL AND ENDOCARDIAL LEAD SYSTEMS

被引:177
|
作者
ZIPES, DP
ROBERTS, D
机构
[1] Department of Medicine, Indiana Univ. School of Medicine, Krannert Institute of Cardiology, Indianapolis, IN
[2] Krannert Institute of Cardiology, Indianapolis, IN 46202-4800
关键词
DEFIBRILLATION; DEATH; SUDDEN; MORTALITY PACEMAKERS;
D O I
10.1161/01.CIR.92.1.59
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The purpose of the present report was to document clinical experience derived from the implantation of 2834 epicardial and endocardial cardioverter-defibrillators (ICDs) in 2807 patients who were followed for almost I year and to compare he results obtained with the two systems. Methods and Results Patients in the two groups had similar clinical characteristics. More than half of the patients had a total of almost 50 000 spontaneous ventricular tachyarrhythmias that were terminated with equal success (approximate to 98%) by epicardial and endocardial ICDs. Lead dislodgement and pocket infection occurred more often with the endocardial than with the epicardial ICD, whereas perioperative mortality was higher with the epicardial ICD than with the endocardial ICD. Mortality from sudden cardiac death was 1.4% in the epicardial ICD group and 0.6% in the endocardial ICD group at 1 year (P=.069). Overall mortality at 1 year was 12.2% and 6.9% for the epicardial and endocardial groups, respectively (P<.001), reflecting the higher surgical mortality for the epicardial system. Conclusions The endocardial ICD is as effective as the epicardial ICD but incurs lower perioperative mortality.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] Pacemaker/implantable cardioverter-defibrillator problem: Right ventricular lead missensing in a biventricular implantable cardioverter-defibrillator
    Otten, Richard F.
    Foreman, Lynne D.
    Groh, William J.
    HEART RHYTHM, 2008, 5 (01) : 158 - 159
  • [2] COMBINED AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR AND PACEMAKER SYSTEMS
    FURMAN, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (01) : 132 - 133
  • [3] PACEMAKER AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR ELECTROCARDIOGRAPHY
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (10): : 1943 - 1944
  • [4] Patients with Pacemaker or Implantable Cardioverter-Defibrillator
    Schulman, Peter M.
    Rozner, Marc A.
    Sera, Valerie
    Stecker, Eric C.
    MEDICAL CLINICS OF NORTH AMERICA, 2013, 97 (06) : 1051 - +
  • [5] Pacemaker/implantable cardioverter-defibrillator interaction
    Jimenez, Alejandro
    Dickfeld, Timm
    Saliaris, Anastasios
    Shorofsky, Stephen
    HEART RHYTHM, 2010, 7 (08) : 1157 - 1160
  • [6] Extraction of endocardial implantable cardioverter-defibrillator leads
    Le Franc, P
    Klug, D
    Jarwe, M
    Lacroix, D
    Delfaut, P
    Kouakam, C
    Kacet, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (02): : 187 - 191
  • [7] A stepwise testing protocol for modern implantable cardioverter-defibrillator systems to prevent pacemaker-implantable cardioverter-defibrillator interactions
    Glikson, M
    Trusty, JM
    Grice, SK
    Hayes, DL
    Hammill, SC
    Stanton, MS
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (03): : 360 - 366
  • [8] HIGH FAILURE RATE FOR A CHRONIC EPICARDIAL IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD
    BRADY, P
    FRIEDMAN, PA
    TRUSTY, JM
    GRICE, SE
    HAMMILL, SC
    STANTON, MS
    CIRCULATION, 1995, 92 (08) : 716 - 716
  • [9] SURGICAL CHECKLIST TO REDUCE PACEMAKER AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD DISLODGEMENTS
    Timmerman, N. P.
    Morillo, C.
    Ribas, S.
    Connolly, S. J.
    Divakaramenon, S.
    Healey, J. S.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S360 - S360
  • [10] A hybrid endocardial-epicardial biventricular implantable cardioverter-defibrillator to circumvent the tricuspid valve
    Ip, James E.
    Krishnan, Udhay
    Girardi, Leonard N.
    Lerman, Bruce B.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (02): : 399 - 401