THERMOLUMINESCENCE AND EXOELECTRONIC EMISSION OF DOSIMETERS BASED ON CASO(4)

被引:0
|
作者
Santos, Max Anderson [1 ]
Junot, Danilo Oliveira [1 ]
Souza, Divanizia Nascimento [1 ]
机构
[1] Univ Fed Sergipe, Sao Cristovao, SE, Brazil
来源
关键词
dosimetry; thermoluminescence; thermoluminescent dosimeter;
D O I
10.7198/S2237-07222012000100003
中图分类号
C93 [管理学];
学科分类号
12 ; 1201 ; 1202 ; 120202 ;
摘要
Different materials have been proposed in the literature for use in personal and environmental dosimetry. Thermoluminescent detectors are widely used in these dosimetric procedures. The motivation for this work was to produce CaSO4 crystals doped with unusual elements such as europium (Eu) and silver (Ag). The thermoluminescence and thermally stimulated exoeletronic emission of new materials produced were investigated. The new routes for the preparation of dosimeters proved to be viable, with the TL emission of CaSO4: Eu, Ag the most intense among the samples studied.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [31] Thermoluminescence characteristics of CaSO4 doped with Eu impurities
    Zhang, CX
    Tang, Q
    Luo, DL
    ACTA PHYSICA SINICA, 2002, 51 (12) : 2881 - 2886
  • [33] Thermoluminescence characteristics of CaSO4 doped with Eu impurities
    Zhang, Chun-Xiang
    Tang, Qiang
    Luo, Da-Ling
    Wuli Xuebao/Acta Physica Sinica, 2002, 51 (12): : 2885 - 2886
  • [34] EXOELECTRONIC EMISSION IN PROCESS OF CREEP
    ROZENMAN, GI
    METAL SCIENCE AND HEAT TREATMENT, 1976, 18 (3-4) : 264 - 266
  • [35] CASO4 (DY) THERMOLUMINESCENT DOSIMETERS FOR DETERMINATION OF GONADAL DOSES
    HASMAN, A
    GROOTHEDDE, RT
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1975, 14 (04): : 369 - 375
  • [36] EXOELECTRONIC EMISSION OF GERMANIUM AND SILICON
    KRYUK, VI
    KORTOV, VS
    MINTS, RI
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII FIZIKA, 1968, (01): : 118 - &
  • [37] Novel non-thermoluminescent CaSO4:Dy dosimeters
    Castro-Campoy, A. I.
    Cruz-Vazquez, C.
    Perez-Salas, R.
    Castano, V. M.
    Bernal, R.
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [38] THIN FILM PHOSPHORS OF CASO4(MN) AS THERMOLUMINESCENT DOSIMETERS
    NAKAJIMA, T
    HABU, T
    HASHIZUM.T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1967, 4 (08): : 446 - &
  • [39] LOW-DOSE MEASUREMENTS WITH CASO4DY, CASO4TM AND CASO4DY TEFLON DOSIMETERS - A COMPARATIVE-STUDY
    LAKSHMANAN, AR
    JOSE, MT
    RADIATION PROTECTION DOSIMETRY, 1993, 46 (03) : 181 - 187
  • [40] MEASUREMENT OF THE ENERGY RESPONSE OF LIF-TL-DOSIMETERS, CAF2-TL-DOSIMETERS AND CASO4-TL-DOSIMETERS
    VANA, N
    AIGINGER, H
    ERATH, W
    MICHEV, T
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1982, 52 (3-4): : 341 - 345